Maximum Temperature Measurement:
+400 (T) °C, +750 (J) °C, +1000 (K) °C
Display Type:
LCD
Number of Readings Per Channel:
2000000
Sensor Type:
J, K, T, Thermocouple
Power Source:
Battery
IP Rating:
IP54
Alarm:
Yes
Model Number:
176-T4
Includes:
Battery, Calibration Protocol, Padlock, Wall Bracket
Humidity Measurement Resolution:
0.1%RH
Best Temperature Measurement Accuracy:
±1 %
Battery Life:
8 Years
Data Logger Type:
Temperature
Interface Type:
USB
Measurement Parameters:
Temperature
Battery Type:
AA
Temperature Measurement Resolution:
0.1°C
Maximum Operating Temperature:
+70°C
Minimum Operating Temperature:
-20°C
Number of Input Channels:
4
Dimensions:
103 x 63 x 33mm
testo 176 series High Accuracy Temperature Data Loggers,The new testo 176 series data loggers have a USB and an SD card interface, making readout of the data fast and easy Data security Password protection Anti-theft lock Robustness Large display Longer battery life Large memory Model testo 176-T1 testo 176-T2 testo 176-T3 testo 176-T4 1-channel temperature logger in metal housing with highly accurate internal sensor (Pt100) Accurate temperature measurement under extreme conditions Robust metal housing protects from mechanical influences such as impact 2-channel temperature logger with connections for highly accurate external sensor (Pt100) Highly accurate measurement in the food sector and in laboratories Temperature monitoring e.g. in refrigerators with highly accurate Pt100 probes 4-channel temperature data logger in metal housing with external sensor connection (TC Type T, Type K and Type J) Parallel temperature measurement at up to four measurement sites using different connectable thermocouple probes for different applications. Robust metal housing protects from mechanical influences such as impact 4-channel temperature data logger with external sensor connections (TC Type T, Type K and Type J) Parallel temperature measurement at up to four measurement sites using different connectable thermocouple probes for different applications. Easy monitoring and documentation e.g. of the flow and return temperature of an underfloor heating system at up to four measurement sites simultaneously Sensor Pt100 class A Pt100 class A TC(Types T, K and J) TC(Types T, K and J) Channels 1 x internal 2 x external 4 x external 4 x external Measuring range -35 → +70 °C -50 → +400 °C -200 → +400 °C (Type T) -195 → +1000 °C (Type K) -100 → +750 °C (Type J) -200 → +400 °C (Type T) -195 → +1000 °C (Type K) -100 → +750 °C (Type J) Accuracy ± 0.2 °C (-35 → +70 °C) ±0.2 °C (-50 →...
Reviews