This is manufactured by Omron Automation and Safety. The manufacturer part number is LY1F-AC100/110. While the must release voltage is a 33 vac. It is assigned with possible HTSUS value of 8536.49.0075. The product is rohs compliant. The coil voltage of the product is 110vac. Moreover, it has plug in terminal style. The product has -25°c ~ 55°c operating temperature range. It is approved by ce, csa, tuv, ur. It holds up to 3.75 kohms coil resistance. It has a coil current of 11 ma. The coil is a non latching type. The product's switching voltage is 250vac, 125vdc - max. On the other hand, 88 vac is the given crucial/must operating voltage. This is basically a general purpose. It also has a spdt (1 form c) contact form. Its typical moisture sensitivity level is 1 (unlimited). The operating time of the product is 25 ms. It has a long 13 weeks standard lead time. It has a contact current rating of 15 a. The product is available in chassis mount configuration. The product ly, is a highly preferred choice for users. While 25 ms is its release time. In addition, bulk is the available packaging type of the product. The product is made from sturdy silver alloy materials. Moreover, it corresponds to ly1f-ac, a base product number of the product. The product is designated with the ear99 code number.