Deliver to
United Kingdom
This is manufactured by Omron Automation and Safety. The manufacturer part number is MY4N DC100/110 (S). It is assigned with possible HTSUS value of 8536.49.0050. The product is rohs3 compliant. The coil voltage of the product is 110vdc. Moreover, it has plug in terminal style. In addition, it is reach unaffected. The product has -55°c ~ 70°c operating temperature range. It holds up to 11.1 kohms coil resistance. It has a coil current of 9 ma. The coil is a non latching type. The product's switching voltage is 250vac, 125vdc - max. On the other hand, 88 vdc is the given crucial/must operating voltage. This is basically a general purpose. It is shipped in bulk package . It also has a 4pdt (4 form c) contact form. Its typical moisture sensitivity level is 1 (unlimited). The operating time of the product is 20 ms. While the must release voltage is a 11 vdc. It has a long 9 weeks standard lead time. It has a contact current rating of 3 a. The splendid features of the product include lighted indicator. The product is available in socketable configuration. The product my, is a highly preferred choice for users. While 20 ms is its release time. The product is made from sturdy silver (ag) materials. Moreover, it corresponds to my4n dc, a base product number of the product. The product is designated with the ear99 code number.
For more information please check the datasheets.
Basket Total:
£ 0