Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Aico Profile

Aico is a public, UK-based company founded in 1990 that has been engaged in manufacturing and distributing public safety components for over 30 years. The company produces an extensive range of safety alarms, including heat alarms, smoke alarms, carbon monoxide alarms, and distinct varieties of sensors. Besides, Aico’s smart home products are also popular among users for their cutting-edge technology and Internet of Things applications. The company’s sophisticated alarm systems guarantee home protection, quality, and innovation. Aico also provides fire alarm kits and heat detectors embedded with multi-sensor technologies. Additionally, the company serves diverse groups of customers by providing bespoke products’ accessories, and modules with a synergetic approach.

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Aico




New Items
New items
Ei3000MRF, Aico

Ei3000MRF, Aico

The Aico SmartLINK module allows for wireless interconnection and data extraction. Simply plug in to any 3000 series alarm and is compatible with other Aico wireless interconnection products. Remote alarm learn entry Transmits, receives and repeats RF specific data RF mesh architecture Unique house coding feature
New items
Ei408, Aico

Ei408, Aico

The Aico switched input module has been designed to triggers the alarms in a system if an external device is activated, such as a sprinkler system. Connects with the alarm system using RadioLINK wireless interconnection technology Connects wirelessly with all other Aico wireless interconnection products
New items
Ei3016, Aico

Ei3016, Aico

The Aico optical smoke alarm contains tried and tested high performance optical smoke sensor, which is best for detecting slow, smoldering fires. In addition, the smoke chamber design, integrated insect screen and unique automatic dust compensation reduce the risk of false alarms. Contains a high performance optical sensor Mains powered with 10 year rechargeable lithium cell back-up Add an Ei3000MRF module for wireless interconnection and data extraction AudioLINK data extraction technology Compatible with other Aico mains powered devices Easi-fit base
New items
Ei208, Aico

Ei208, Aico

The Aico carbon monoxide alarm is a standalone battery unit, powered by 10 year life sealed in lithium cell. The battery can not be removed ensuring continued protection. Easy to fit twist on base and multi-fixings Proven electrochemical sensor Pre-alarm LED indication give early warning of CO
New items
EI407, Aico

EI407, Aico

RadioLINK Remote Manual Call Point Allows manual alarm to warn other residents. Operates as a conventional break glass call point, but is totally wire free when used with the fire alarms in this range and the RadioLINK Multi Level Repeater Interconnect Base. Up to 12 RadioLINK units can be used in one system. Requires no wiring and is a manual alarm point used in emergency to place the system in to alarm Is totally wire free having its own special ten year cell to provide its own operating voltage Low battery warning signal - LED indicator flashes amber every 40 seconds to indicate a depleted battery Ambient temperature range : 4 to 40°C. Humidity range : 0 to 90% relative humidity Up to 12 RadioLINK units can be used in one system Dimensions: 85mm x 85mm x 57mm deep (including mounting box) Standards CE marked to indicate conformance to BS EN 60065 : 1998 (Electrical Safety), EN300220-1 V1.3.1 (2000-09) (RF Performance), EN30189 V1.4.1 (2002-08) (EMC) and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 : Pt.1 : 2000. Wireless Fire Alarm System Interconnecting mains powered smoke alarms is essential to provide the earliest possible warning of a fire. By using wireless signals with the RadioLINK products in this range to interconnect smoke alarms, it is simpler and more convenient than using the conventional hard wired system. It is also easier to extend or change the system when required. The use of radio interconnection in Grade D alarm systems means that it is now much easier to comply with the extended alarm coverage recommended in BS 5839: Pt.6: 2004. As a guide, 30m should be the maximum distance between any of the alarms in the system.
New items
EI164RC, Aico

EI164RC, Aico

Heat Alarm Intended for wireless use with the other RadioLINK products in this range, however can also be used alone. It meets all regulations and code of practice for smoke alarm installations and systems. Fixed temperature thermistor type sensor, triggering temperature 54°C ± 4°C Designed to minimise the risk of nuisance alarms, thus avoiding alarms being disabled 230V AC mains power supply with built in tamper proof rechargeable lithium cells which have a lifespan of 10 years Easi-fit built in surface mounting plate, with integral terminal block and cable cover Encased horn assembly gives a minium sound output of 85dB(A) at 3 metres Cells are soldered for reliable long term connection Terminals are laser welded for reliability Radio control function allows testing, alarm hush and fire locate from an accessible switch position LED mains indicator Warning signal to indicate low power cell Self monitoring every 40 seconds Ambient temperature range : 0 to 40°C Dust cover fitted Dimensions : 140mm diameter x 78mm depth Standards BSI Kitemark to indicate type testing to BS 5446: Pt. 2 : 2003, Class A1. Meets the requirements of Grade D (and exceeds the requirements of Grades E and F) as defined in BS 5839: Pt. 6 : 2004. CE mark to indicate conformance to Low Voltage and Electromagnetic Compatibilty Directives. Wireless Fire Alarm System Interconnecting mains powered smoke alarms is essential to provide the earliest possible warning of a fire. By using wireless signals with the RadioLINK products in this range to interconnect smoke alarms, it is simpler and more convenient than using the conventional hard wired system. It is also easier to extend or change the system when required. The use of radio interconnection in Grade D alarm systems means that it is now much easier to comply with the extended alarm coverage recommended in BS 5839: Pt.6: 2004. As a guide, 30m should be the maximum distance between any of the alarms in the system.
New items
Ei412, Aico

Ei412, Aico

The Aico RadioLINK alarm control switch is used to control all the alarms in a system from one place. It is powered by a tamper-proof, sealed in lithium cell giving a completely wire free installation with a 10 year life and connects wirelessly using RadioLINK interconnectionradio technology, so once in place you will need to House Code the switch into the alarm system. Test, Locate and Silence from one unit For use with fire and CO domestic systems
New items
Ei128R, Aico

Ei128R, Aico

The Aico mains powered relay module triggers external devices, such as a strobe light or telecare device, if the alarms in the property activate. Connects with the alarm system through a hard wire interconnect Easy to install with additional trunking knock outs easi-fit base footprint
New items
EI428, Aico

EI428, Aico

RadioLINK Remote Relay Module Intended for use with the smoke alarms in this range, fitted to the RadioLINK Multi Level Repeater Interconnect Base. Used as an interface with a host of other alarms or warning systems, eg warden call, dial out units. It is operated by radio signals sent by the other RadioLINK alarms in the system. Up to 12 RadioLINK units can be used in one system. Mains powered with a rechargeable lithium cell back-up Low back-up warning signal, LED indicator flashes RED every 10 seconds to indicate that the lithium cells are depleted Ambient temperature range : 4 to 40°C Humidity range : 0 to 90% relative humidity Volt free contacts - (normally open or normally closed) rated up to 240V AC / 5 Amps, making it suitable for use with a wide range of AC or DC voltages. The relay contacts operate on mains power, or on back-up cells in the event of a mains failure Feature 1 x 25mm trunking for surface wiring and centre knockout for recess wiring Dimensions : 140mm diamater x 27mm depth Standards CE marked to indicate conformance to BS EN 60065 : 1998 (Electrical Safety), EN300220-1 V1.3.1 (2000-09) (RF Performance), EN301489 V1.4.1 (2002-08) (EMC) and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 : Pt.1 : 2000. Wireless Fire Alarm System Interconnecting mains powered smoke alarms is essential to provide the earliest possible warning of a fire. By using wireless signals with the RadioLINK products in this range to interconnect smoke alarms, it is simpler and more convenient than using the conventional hard wired system. It is also easier to extend or change the system when required. The use of radio interconnection in Grade D alarm systems means that it is now much easier to comply with the extended alarm coverage recommended in BS 5839: Pt.6: 2004. As a guide, 30m should be the maximum distance between any of the alarms in the system.
New items
Ei3014, Aico

Ei3014, Aico

The Aico heat alarm contains our tried and tested high performance thermistor heat sensor providing protection from fire. The thermistor has a smaller thermal mass enabling it to give faster alarm responses when the trigger temperature of 58°C is reached. The alarm is best for detecting heat build-up from large flaming fires. Contains a fast response thermistor heat sensor Mains powered with 10 year rechargeable lithium cell back-up AudioLINK data extraction technology Fasi-fit base
New items
EI168RC, Aico

EI168RC, Aico

RadioLINK Multi Level Repeater Interconnect Base At the heart of the RadioLINK system is the Ei168 base unit, which is fully compatible with any of the fire alarms mentioned in this range. It is from here that radio signals are transmitted and received. An Ei168 base is required for each of the alarms in the system. The radio frequency protocol is well proven, extremely robust and is unaffected by external signals. Up to 20 units can be used in one system. Mains powered (230V AC) with rechargeable 10 year+ lithium cell back-up Radio transceiver 868.499 MHz Unique Easi-fit design with integral terminal block Simple and secure house coding system Interference free Ambient temperature range: 4 to 40°C Humidity range : 0 to 90% relative humidity Dimensions : 140mm diameter x 200mm depth Remote control for test, hush and fire locate is achieved with totally wire free devices Standards BS EN 60065 : 1998 (Electrical Safety), EN300220-1 V1.3.1 (2000-09) (RF Performance), EN301489 V1.4.1 (2002-08) (EMC) and has been third party tested for electrical safety in accordance with Annex K of BS 5446 : Pt.1 : 2000. Wireless Fire Alarm System Interconnecting mains powered smoke alarms is essential to provide the earliest possible warning of a fire. By using wireless signals with the RadioLINK products in this range to interconnect smoke alarms, it is simpler and more convenient than using the conventional hard wired system. It is also easier to extend or change the system when required. The use of radio interconnection in Grade D alarm systems means that it is now much easier to comply with the extended alarm coverage recommended in BS 5839: Pt.6: 2004. As a guide, 30m should be the maximum distance between any of the alarms in the system.
New items
Ei450, Aico

Ei450, Aico

The Aico RadioLINK alarm controller is used to control all the alarms in a system from one place. It contains LED’s which clearly display which danger has activated the alarm – helping to you take the appropriate action as quickly as possible. Battery powered by a sealed in Lithium cell 10 year life Completely wire free installation Connects wirelessly with all other Aico wireless interconnection products