Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Products Found: 435

Showing Results For: PCB Transformers

PCB Transformers


FILTERS
Filters
Showing
1 -

Rates

1+
£ 39.68
10+
£ 38.06
25+
£ 35.00
Availability
11 In Stock

Rates

1+
£ 8.82
10+
£ 8.40
25+
£ 7.51
Availability
8 In Stock

Rates

1+
£ 10.20
10+
£ 9.81
25+
£ 8.98
Availability
61 In Stock

Rates

1+
£ 12.50
10+
£ 12.03
25+
£ 11.06
Availability
155 In Stock

Rates

35+
£ 10.14
Availability
47 In Stock

Rates

1+
£ 12.92
10+
£ 12.43
25+
£ 11.45
Availability
50 In Stock

Rates

1+
£ 21.94
10+
£ 21.50
25+
£ 21.08
Availability
48 In Stock

Rates

12+
£ 37.99
Availability
22 In Stock

Rates

12+
£ 20.84
Availability
10 In Stock

Rates

1+
£ 7.62
10+
£ 7.24
25+
£ 6.63
Availability
95 In Stock

Rates

1+
£ 12.23
25+
£ 11.62
50+
£ 11.03
Availability
13 In Stock

Rates

160+
£ 4.70
Availability
401 In Stock

Rates

35+
£ 8.78
175+
£ 7.90
350+
£ 7.34
Availability
103 In Stock

Rates

1+
£ 7.24
25+
£ 6.57
50+
£ 6.22
Availability
1 In Stock

Rates

1+
£ 1.85
Availability
88 In Stock

Rates

1+
£ 10.53
10+
£ 7.90
50+
£ 6.14
Availability
95 In Stock

Rates

35+
£ 10.15
Availability
91 In Stock

Rates

35+
£ 10.14
175+
£ 9.13
350+
£ 8.32
Availability
90 In Stock

Rates

20+
£ 16.75
Availability
22 In Stock

Rates

1+
£ 3.38
25+
£ 3.22
50+
£ 3.07
Availability
26 In Stock

Rates

1+
£ 8.66
25+
£ 8.22
50+
£ 7.82
Availability
753 In Stock

Rates

1+
£ 32.34
25+
£ 30.05
Availability
76 In Stock

Rates

35+
£ 13.99
Availability
173 In Stock

Rates

35+
£ 9.18
175+
£ 8.26
350+
£ 7.53
Availability
383 In Stock

Rates

48+
£ 17.48
240+
£ 15.73
480+
£ 14.33
Availability
59 In Stock
Showing
1 -

New Items
New items
PT 22/2/15, Block

PT 22/2/15, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø 1.5 20 ...
New items
AVB2.3/2/24, Block

AVB2.3/2/24, Block

Transformers PCB Mount, Short Circuit Proof, AVB Series Dual 115Va.c. 50 to 60Hz primary Twin secondary windings for series or parallel connection AVB series are inherently short circuit proof compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Isolation Primary to Secondary 5kV Protection Class 2 Insulation: Class B (130°C) Class A (105°C) Max Ambient Temperature +70°C Approvals VDE 0570/EN 61 558, UL 506, CSA 22.2
New items
PT 4.5/2/9, Block

PT 4.5/2/9, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø ...
New items
44442, Myrra

44442, Myrra

Type EI 60 / 21.2 → 22 VA transformers Secondary voltages are nominal load voltages on resistive loads. Primary voltage: 230 V Current consumption: 125 mA Height (mm) - transformer:  47.75 - soldering pins:  4.5 Total P / S insulation: > 4000 V Pins: - primary: 1 → 7 - 2 secondaries: 8 → 9  13 → 14 Approvals UL, VDE Encapsulated – Toroidal Maximum Operating Temperature +60°C Primary – Secondary Test Voltage 4 kV UL Recognised for Insulation Class A +105°C Meets All Requirements of Class E +120°C Pin Length x Diameter 1 x 0.5 mm Note Fixing screws not provided
New items
VCM 25/1/6, Block

VCM 25/1/6, Block

PCB Mount 230Vac Primary VC/VCM Series Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise 100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA) Selection Guide VA Rating Pin configuration (mm) P1 S1 S2 A 3.2VA 20 10 5 25 5VA 25 15 5 25 10VA 25 15 5 27.5 16VA 30 20 5 30 Selection Guide VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A 25VA 72.5 43.5 30 20 5 32.5 36VA 77.5 47.5 35 20 5 35 50VA 82 37.5 35 15 - 35 Isolation Primary to Secondary 5kVac Secondary to Secondary 250Vac Protection Class 2 Insulation Class B (130°C) Pin Length x Diameter 5mm x 0.8mm Max. Ambient Temperature 3.2VA +60°C,5VA +50°C, 10 to 36VA +40°C Note To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series. Standards EN 61 558 IEC 61558 Approvals ENEC, UL recognised
New items
VB 0.5/2/6, Block

VB 0.5/2/6, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø ...
New items
VB 0.35/2/15, Block

VB 0.35/2/15, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø ...
New items
VB 1.5/2/9, Block

VB 1.5/2/9, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø ...
New items
VC 10/2/15, Block

VC 10/2/15, Block

PCB Mount 230Vac Primary VC/VCM Series Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise 100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA) Selection Guide VA Rating Pin configuration (mm) P1 S1 S2 A 3.2VA 20 10 5 25 5VA 25 15 5 25 10VA 25 15 5 27.5 16VA 30 20 5 30 Selection Guide VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A 25VA 72.5 43.5 30 20 5 32.5 36VA 77.5 47.5 35 20 5 35 50VA 82 37.5 35 15 - 35 Isolation Primary to Secondary 5kVac Secondary to Secondary 250Vac Protection Class 2 Insulation Class B (130°C) Pin Length x Diameter 5mm x 0.8mm Max. Ambient Temperature 3.2VA +60°C,5VA +50°C, 10 to 36VA +40°C Note To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series. Standards EN 61 558 IEC 61558 Approvals ENEC, UL recognised
New items
VB 2,8/1/6, Block

VB 2,8/1/6, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø ...
New items
FL 24/9, Block

FL 24/9, Block

PCB Mounting Low Profile 115 / 230Vac Primary Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing holes for secure board mounting Standard: EN60742, VDE 0551, IEC 61558 Selection Guide VA Rating Fixing Centres Pin Configuration C1 C2 P1 P2 S1 S2 A 4 VA 37.5 47.5 15 10 25 5 35 6 VA 37.5 47.5 15 10 25 5 35 10 VA 50 62.5 16 15 26 10 45 14 VA 50 62.5 16 15 26 10 45 18 VA 50 62.5 16 15 26 10 45 24 VA 50 62.5 16 15 26 10 45 30 VA 50 62.5 16 15 26 10 45 42 VA 60 75 27 15 37 10 53.5 52 VA 60 75 27 15 37 10 53.5 Isolation Primary to secondary 5kV Primary to primary 1kV Secondary to secondary 250V Protection Class 2 Insulation Class E (120°C) Class A (105°C) Max. Ambient Temperature +40°C Pin Diameter (mm) 0.8 mm Fixing: mechanical fixings can be supplemented by 4 self tapping screws (no. 4 x 9.5mm max. on the 2VA to 30VA transformers and M3 on the 42 and 52VA transformers) using holes mounted in the corners of the case Note: For conformance reasons, transformer with 2 x 24V outputs should not have their secondaries connected in series Note Transformer with 2 x 24V outputs are not VDE, SEV approved. Standards VD 61 558
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like PCB Transformers and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding PCB Transformers or any other product.
This depends on the PCB Transformers individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for PCB Transformers and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including PCB Transformers.
Yes. We keep updating our stock frequently and if a product like PCB Transformers is not in stock then we will let you know.