Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
HOBUT Profile

Hobut (Howard Butler), established in 1915 in the UK, is a market specialist in manufacturing control products and instruments exported worldwide. The company is the largest brand in the field, consisting of innovative products, including ammeters, current transformers, digital & analogue meters, shunts, voltmeters, selector switches, synchroscopes, multifunctional transducers, panel meters, energy meters, battery charger meters, automotive products, protection & earth leakage relays, and battery condition indicators. Experts dedicatedly design these cutting-edge products in the UK to meet industry standards and users’ requirements. With huge manufacturing warehouses in the UK, Hobut manufactures over 40,000 current transformers and 20,000 panel meters per month with over 120 skilled employees. The company has supply chains in various countries and ranks among the top industries in the field.

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For HOBUT




New Items
New items
18-5-K6, HOBUT

18-5-K6, HOBUT

Compact Busbar/Base Mounting Current Transformers- Series 18 A range of compact moulded case current transformers suitable for primary currents from 400A to 1600A with built-in sealable terminal covers. The current transformers are used to transform various primary currents into 5A or 1A standard secondary using up to 60 x 15 mm or 50 x 30 mm busbars. Alternatively you can also use cables up to 45 mm diameter. • Built in sealable terminal covers • Mounting feet supplied • Narrow width- 85 mm • Wide range of primary current • Rated system voltage 0.72/3 kV • Continuous current 1.2 x rated current • Conforms to IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Current Transformers
New items
D96SD DIAL 0/200A, HOBUT

D96SD DIAL 0/200A, HOBUT

Scales for DIN Standard Meters Panel meter scales suitable for DIN-standard 72 mm and 96 mm CT operated moving iron ammeters. Scales are available for both standard and overload meters.
New items
CT173M120/5-2.5/1-002, HOBUT

CT173M120/5-2.5/1-002, HOBUT

Moulded Case Current Transformer – 24mm Aperture Power consumption 2.5VA, 50/60Hz Accuracy class 1 20 or 30mm busbar mounting Suitable for circular conductors 24 aperture Maximum aperture for bar conductors 30x10mm (type 6) Operating temperature range –30 to +85°C Secondary terminals M5 studs with lock washers, nuts and terminal cover Full scale deflection currents can be selected by passing more than one conductor turn through the centre of the transformer, see adjacent table Protection to IP54 BS7627/IEC185 and IEC60044-1 Conforms to BS 3938-1973 and IEC CE marked in compliance with relevant European Directives Manufactured to ISO 9001 Technical Specification CT Ratio Full Scale Deflection (A) 1 Turn 2 Turns 3 Turns 4 Turns 5 Turns 120:5 120 60 40 30 24 150:5 150 75 50 37.5 30 200:5 200 100 66.7 50 40 300:5 300 150 100 75 60 400:5 400 200 133.3 100 80 Supplied with base mounting feet and M5 captive nuts. Current Transformers
New items
CT143M300/5-5/1-001, HOBUT

CT143M300/5-5/1-001, HOBUT

Compact Busbar/Base Mounting Current Transformers - Series 14 A range of compact moulded case current transformers suitable for primary currents from 25A to 500A with built-in sealable terminal covers. For transforming various primary currents into 5A standard secondary current using 20mm or 30mm busbars or 24mm cables. DIN rail mounting clip supplied Built-in sealable terminal covers Mounting feet and busbar screws supplied Narrow width Dimensions: H70 x W49 x D30mm Conforms to IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Rated system voltage: 0.72/3kV Ambient temperature range: -30 to 85°C Continuous current: 1.2 x rated current Current Transformers
New items
R68M-50A-001, HOBUT

R68M-50A-001, HOBUT

High Current Battery Charge Moving Magnet Meter For use with DC and rectified AC only Suitable for high current battery charger applications Case fitted with black and white bezel Snap-in panel or U-clip fixing Stud terminal electrical connections Size 82 x 68 mm Moving Iron/Moving Magnet, Battery Charge All have an operating temperature range of -20 to +40°C
New items
CT132M250/5-2.5/0.5, HOBUT

CT132M250/5-2.5/0.5, HOBUT

Compact Busbar/ Base Mounting Current Transformers - Series 13 A range of compact moulded case current transformers suitable for primary currents from 40A to 300A with built in sealable terminal covers. For transforming various primary currents into 5A standard secondary using up to 20mm diameter cables. DIN rail mounting clip supplied Built in sealable terminal covers Mounting feet supplied Narrow width: 45mm Dimensions: H65 x W45 x D30mm 21mm aperture Conforms to IEC185, BS 7626, BSEN 60044-1and IEC 60044-1 Rated system voltage: 0.72/3kV Ambient temperature range: -30 to 85°C Continuous current: 1.2 x rated current CT Class Information for Series 16 331-395 - Class 1 331-547 - Class 1 331-373 - Class 0.5 331-367 - Class 0.5 331-446 - Class 0.5 Current Transformers
New items
CT132M120/5-2.5/1, HOBUT

CT132M120/5-2.5/1, HOBUT

Compact Busbar/ Base Mounting Current Transformers - Series 13 A range of compact moulded case current transformers suitable for primary currents from 40A to 300A with built in sealable terminal covers. For transforming various primary currents into 5A standard secondary using up to 20mm diameter cables. DIN rail mounting clip supplied Built in sealable terminal covers Mounting feet supplied Narrow width: 45mm Dimensions: H65 x W45 x D30mm 21mm aperture Conforms to IEC185, BS 7626, BSEN 60044-1and IEC 60044-1 Rated system voltage: 0.72/3kV Ambient temperature range: -30 to 85°C Continuous current: 1.2 x rated current CT Class Information for Series 16 331-395 - Class 1 331-547 - Class 1 331-373 - Class 0.5 331-367 - Class 0.5 331-446 - Class 0.5 Current Transformers
New items
D72SD DIAL 0/80/480A, HOBUT

D72SD DIAL 0/80/480A, HOBUT

Scales for DIN Standard Meters Panel meter scales suitable for DIN-standard 72 mm and 96 mm CT operated moving iron ammeters. Scales are available for both standard and overload meters.
New items
D72MC75MV/0-30A, HOBUT

D72MC75MV/0-30A, HOBUT

DC Voltage and Current Meters 90° scale arc Accuracy class 1.5; BS89 and IEC51 Flame retardant case to UL94V0 Fitted with mounting brackets Operating temperature range -25 → +40°C Terminal covers available separately 48x48mm ammeters have integral scales; appropriate scales must be chosen and ordered separately for the 72x72 & 96x96mm ammeters Note All ammeters are shunt operated and an appropriate 75mV shunt (no. 257-307 typically) must be ordered separately for each meter; the meters cannot be used without them
New items
SHR60A60, HOBUT

SHR60A60, HOBUT

60mV Ammeter Brass-Ended Shunt For use with DIN dc ammeters or any panel meter with a full scale deflection of 60mV and an input impedance of 75Ω or more. Shunts
New items
CT153M120/5-2.5/1, HOBUT

CT153M120/5-2.5/1, HOBUT

Universal Mounting Current Transformer - 26mm Aperture Three built-in fixing methods: Base, DIN-rail & Busbar mounting Case moulded in high-impact polyester with built in hinged terminal cover Cables up to 26mm outside diameter, bars up to 30mm wide, or a conducting bush 24mm wide Accuracy Class 1, Power consumption 2.5VA, 50/60Hz For use with 5A moving iron meters or cam-operated selector switches Secondary winding epoxy resin insulated Enclosed to IP20 Temperature range: -20 to 70°C Conforms to BS7627/IEC185 Current Transformers