Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Products Found: 23

Showing Results For: Current Probes & Clamps

Current Probes & Clamps


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Chauvin Arnoux
PAC17, Chauvin Arnoux
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 224.60
Chauvin Arnoux
PAC27, Chauvin Arnoux
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 323.80
Fluke
i30s, Fluke
11 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 637.05
LeCroy
Rohs Verified
CP030-3M, LeCroy
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 3975.75
i2000 FLEX, Fluke
10 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 380.37
i6000s FLEX-24, Fluke
11 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 492.90
I3000S FLEX-24, Fluke
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 474.30
LeCroy
Rohs Verified
CP150-6M, LeCroy
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 4203.60
LeCroy
Rohs Verified
CP030A, LeCroy
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 4240.80
LeCroy
CP500, LeCroy
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 5235.90
FLUKE i310S, Fluke
7 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 422.22
i6000s FLEX-36, Fluke
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 656.58
ISO-TECH
RS_699-1946, ISO-TECH
Pre Order
Check Stock & Lead Times Packaging Options
Chauvin Arnoux
P01120072, Chauvin Arnoux
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 162.42
ISO-TECH
RS_699-1949, ISO-TECH
Pre Order
Check Stock & Lead Times Packaging Options
Metrix
HX0034, Metrix
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 279.00
Chauvin Arnoux
P01120409, Chauvin Arnoux
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 169.00
LeCroy
CP150, LeCroy
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 4738.35
Keysight Technologies
1147B, Keysight Technologies
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 2138.07
LeCroy
Rohs Verified
CP031A, LeCroy
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 5566.05
LeCroy
CP030, LeCroy
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 3650.25
LeCroy
CP031, LeCroy
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 5079.75
Chauvin Arnoux
P01120075, Chauvin Arnoux
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 325.50
Showing
1 -

New Items
New items
PAC17, Chauvin Arnoux

PAC17, Chauvin Arnoux

The PAC Series is a range of Hall-effect current clamps for measuring direct and alternating currents. 2 forms are proposed to clamp cables up to 30 mm or 2x24 mm in diameter, as well as small busbars. The range comprises PAC1x models and PAC2x models for higher currents. When used with an oscilloscope, this isolated current sensor has 2 sensitivities and allows you to view currents with a bandwidth of up to 30 kHz and peak current up to 600 A DC or peak. It is equipped with a simplified ZeroDC adjustment system and a deactivatable automatic standby function. Rated current: 40 AAC/60 ADC - 400 AAC/600 ADC Output signal: DC and AC voltage Output / input ratio: 10 mV / A, 1 mV / A Output via coaxial cable and isolated BNC male plug
New items
CP150-6M, LeCroy

CP150-6M, LeCroy

Teledyne LeCroy CP030-3M and CP150-6M Current Probes Teledyne LeCroy CP Series current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies. Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements. CP030-3M (RS 136-8332) Current Meter, Clamp/Probe (Add On) CAT I 300V Measures AC, DC Current to 30A, 10 MHz CP150-6M (RS 136-8333) Current Meter, Clamp/Probe (Add On) 600V CAT III, 300V CATIII Measures AC, DC Current to 150A RMS, 10 MHz
New items
i6000s FLEX-36, Fluke

i6000s FLEX-36, Fluke

i6000s Flex a.c. Current Probe The Probes can be used to measure ac current up to 6000 A. The flexible measuring head allows current measurements on conductors that are hard to reach or inaccessible using typical clamp-on current probes. Characteristics: Current ranges 60 A / 600 A / 6000 A ac rms Output sensitivity 50 mV / 5 mV / 0.5 mV per A Load impedance 100 kΩ minimum Accuracy (at 25 ºC) ± 1% of range (45 - 65 Hz) Frequency range 10 Hz to 50 kHz (- 3 dB) Phase error ±10° (at 20 kHz) Working voltage 600 V ac rms or dc Cable length 2 m long (78.7 in) (head to electronics) Output connection 0.5 cable terminated with safety BNC connector Standards EN 61010-1: 2001 EN 61010-2-032: 2002 EN 61010-031: 2002 600 V rms Category III, Pollution Degree 2. EN 61326 : 1998 +A1, A2, & A3
New items
RS_699-1946, ISO-TECH

RS_699-1946, ISO-TECH

ISO-TECH ICA3000 Flexible 3000A ac Current Probe Dual range Current Probe suitable for multimeters, recorders and data loggers 2 selectable ac current ranges, 300A and 3000A 2 output sensitivities, 300mV/A and 1V/A Wide bandwidth, low phase shift Terminated with right angle 4mm shrouded plugs Suitable for use with multimeters, recorders and data loggers Complies with EN61010-1 Cat III, 600V AC Current Range 300A 3000A Output select 300mV 1V 300mV 1V Output signal 1mV/A 3.33mV/A 0.1mV/A 0.333mV/A AC Current Accuracy 1% of full scale Linearity (10 to 100%) 0.2% of reading Phase error Bandwidth (-3dB) 10Hz to 10kHz Battery 2 off AA alkaline Battery life (typical) 300 hours Measuring head length 610mm Probe lead length 1700mm Output lead length 1700mm Weight 430g Dimensions 130 x 80 x 43mm Supplied with 2 off AA alkaline batteries and Operator Manual
New items
CP500, LeCroy

CP500, LeCroy

Teledyne LeCroy Current Probes Teledyne LeCroy current probes make accurate and reliable AC, DC and impulse current measurements without requiring the breaking of a circuit or the insertion of a shunt. This capability is based on a combination of Hall effect and transformer technology. Many current probes require external power supplies or amplifiers to display a waveform on the oscilloscope screen. LeCroy current probes are powered through the LeCroy ProBus® connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This integration also allows for Degauss and Autozero functions to be carried out directly from the oscilloscope with the press of a button. Applications of LeCroy current probes include use in the design and test of switching power supplies, motor drives, electric vehicles and uninterruptible power supplies. Rise time (typical) Minimum sensitivity 1mA/div (CPO30A & CPO31A), 10 mA/div (CP030 & CP031), 100 mA/div (CP150 & CP500) AC noise Coupling AC, DC, GND Cable length 1.5 m (CP030 & CP031), 2m (CP150), 6m (CP500) Weight 240g (CP030 & CP031), 500g (CP150), 630g (CP500) Interface ProBus, 1 MΩ only (requires AP-1M for use with 50Ω input only oscilloscopes) Usage environment indoors Operating temperature 0 °C to 40 °C Maximum relative humidity 80% Maximum altitude 2000m Note The CP030 ( 801-4858 ) & CP031 ( 724-0911 ) are compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater. Their Minimum Sensitivity is 10mA/div compared with 1mA/div for CPO30A ( 878-7604 ) & CPO31A ( 878-7607 ). The maximum conductor size for these four models is 5mm od. CP150 ( 801-4855 ) & CP500 ( 724-0918 ) h...
New items
CP031A, LeCroy

CP031A, LeCroy

Teledyne LeCroy Current Probes Teledyne LeCroy current probes make accurate and reliable AC, DC and impulse current measurements without requiring the breaking of a circuit or the insertion of a shunt. This capability is based on a combination of Hall effect and transformer technology. Many current probes require external power supplies or amplifiers to display a waveform on the oscilloscope screen. LeCroy current probes are powered through the LeCroy ProBus® connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This integration also allows for Degauss and Autozero functions to be carried out directly from the oscilloscope with the press of a button. Applications of LeCroy current probes include use in the design and test of switching power supplies, motor drives, electric vehicles and uninterruptible power supplies. Rise time (typical) Minimum sensitivity 1mA/div (CPO30A & CPO31A), 10 mA/div (CP030 & CP031), 100 mA/div (CP150 & CP500) AC noise Coupling AC, DC, GND Cable length 1.5 m (CP030 & CP031), 2m (CP150), 6m (CP500) Weight 240g (CP030 & CP031), 500g (CP150), 630g (CP500) Interface ProBus, 1 MΩ only (requires AP-1M for use with 50Ω input only oscilloscopes) Usage environment indoors Operating temperature 0 °C to 40 °C Maximum relative humidity 80% Maximum altitude 2000m Note The CP030 ( 801-4858 ) & CP031 ( 724-0911 ) are compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater. Their Minimum Sensitivity is 10mA/div compared with 1mA/div for CPO30A ( 878-7604 ) & CPO31A ( 878-7607 ). The maximum conductor size for these four models is 5mm od. CP150 ( 801-4855 ) & CP500 ( 724-0918 ) have Minimum Sensitivity 100mA/div and maximum conductor size 20mm od. Teledyne LeCroy current probes have a ...
New items
i6000s FLEX-24, Fluke

i6000s FLEX-24, Fluke

i6000s Flex a.c. Current Probe The Probes can be used to measure ac current up to 6000 A. The flexible measuring head allows current measurements on conductors that are hard to reach or inaccessible using typical clamp-on current probes. Characteristics: Current ranges 60 A / 600 A / 6000 A ac rms Output sensitivity 50 mV / 5 mV / 0.5 mV per A Load impedance 100 kΩ minimum Accuracy (at 25 ºC) ± 1% of range (45 - 65 Hz) Frequency range 10 Hz to 50 kHz (- 3 dB) Phase error ±10° (at 20 kHz) Working voltage 600 V ac rms or dc Cable length 2 m long (78.7 in) (head to electronics) Output connection 0.5 cable terminated with safety BNC connector Standards EN 61010-1: 2001 EN 61010-2-032: 2002 EN 61010-031: 2002 600 V rms Category III, Pollution Degree 2. EN 61326 : 1998 +A1, A2, & A3
New items
P01120072, Chauvin Arnoux

P01120072, Chauvin Arnoux

PAC12 Oscilloscope clamp for AC/DC current The PAC12 current clamp accurately measures AC or DC currents by using the Hall-effect principle. The current clamp with mV output on BNC (direct reading on oscilloscopes, etc.) is equipped with an automatic DC Zero system. Current calibres: 0.2 A AC to 40 A AC (60 A peak) / 0.4 A DC to 60 A DC 0.5 A AC to 400 A AC (600 A peak) / 0.5 A DC to 600 A DC Output signal: 10 mV AC+DC / A AC+DC (0.6 V for 60 A) 1 mV AC+DC / A AC+DC (0.6 V for 600 A) Max. jaw opening: 31 mm Battery: 9 V alkaline (NEDA 1604A, IEC 6LR61) Standards IEC 1010-1 and IEC 1010-2-032, 600 V category III pollution degree 2, 300 V category IV pollution degree 2 Supplied with Battery and user’s manual.
New items
CP030A, LeCroy

CP030A, LeCroy

Teledyne LeCroy Current Probes Teledyne LeCroy current probes make accurate and reliable AC, DC and impulse current measurements without requiring the breaking of a circuit or the insertion of a shunt. This capability is based on a combination of Hall effect and transformer technology. Many current probes require external power supplies or amplifiers to display a waveform on the oscilloscope screen. LeCroy current probes are powered through the LeCroy ProBus® connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This integration also allows for Degauss and Autozero functions to be carried out directly from the oscilloscope with the press of a button. Applications of LeCroy current probes include use in the design and test of switching power supplies, motor drives, electric vehicles and uninterruptible power supplies. Rise time (typical) Minimum sensitivity 1mA/div (CPO30A & CPO31A), 10 mA/div (CP030 & CP031), 100 mA/div (CP150 & CP500) AC noise Coupling AC, DC, GND Cable length 1.5 m (CP030 & CP031), 2m (CP150), 6m (CP500) Weight 240g (CP030 & CP031), 500g (CP150), 630g (CP500) Interface ProBus, 1 MΩ only (requires AP-1M for use with 50Ω input only oscilloscopes) Usage environment indoors Operating temperature 0 °C to 40 °C Maximum relative humidity 80% Maximum altitude 2000m Note The CP030 ( 801-4858 ) & CP031 ( 724-0911 ) are compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater. Their Minimum Sensitivity is 10mA/div compared with 1mA/div for CPO30A ( 878-7604 ) & CPO31A ( 878-7607 ). The maximum conductor size for these four models is 5mm od. CP150 ( 801-4855 ) & CP500 ( 724-0918 ) have Minimum Sensitivity ...
New items
PAC27, Chauvin Arnoux

PAC27, Chauvin Arnoux

The PAC Series is a range of Hall-effect current clamps for measuring direct and alternating currents. 2 forms are proposed to clamp cables up to 39 mm or 2x25.4 mm in diameter, as well as small busbars. The range comprises PAC1x models and PAC2x models for higher currents. When used with an oscilloscope, this isolated current sensor has 2 sensitivities and allows you to view currents with a bandwidth of up to 30 kHz and peak currents up to 1,400 A DC or peak. It is equipped with a simplified ZeroDC adjustment system and a deactivatable automatic standby function. Rated current: 100 AAC/150 ADC - 1,000 A AC/1,400 A DC Output signal: DC and AC voltage Output / input ratio: 10 mV / A, 1 mV / A Output via coaxial cable and isolated BNC male plug
New items
P01120409, Chauvin Arnoux

P01120409, Chauvin Arnoux

Chauvin Arnoux MN60 Mini Clamps Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c. Safe, non intrusive current measurement 40Hz to 10kHz bandwidth Ergonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cable Max. conductor size 20mm dia. or 20 x 5mm bus bar Fitted with a 2m coaxial lead and 50Ω BNC plug to suit most analogue & digital oscilloscopes Conforms to IEC1010-2-032 (safety standard) 600V Cat III Current range 0.1 to 24A ac 0.5 to 240A ac Accuracy 2% 1.5% Output ratio 100mV ac/1A ac 10mV ac/1A ac Nominal range (In) 20A ac 200A ac Measurement range 0.1A to 24A ac 0.5A to 240A ac Frequency range 40 Hz to 10 kHz Impedance of measuring instrument ≥1MΩ ≤100pF
New items
CP030-3M, LeCroy

CP030-3M, LeCroy

Teledyne LeCroy CP030-3M and CP150-6M Current Probes Teledyne LeCroy CP Series current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies. Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements. CP030-3M (RS 136-8332) Current Meter, Clamp/Probe (Add On) CAT I 300V Measures AC, DC Current to 30A, 10 MHz CP150-6M (RS 136-8333) Current Meter, Clamp/Probe (Add On) 600V CAT III, 300V CATIII Measures AC, DC Current to 150A RMS, 10 MHz
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Current Probes & Clamps and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Current Probes & Clamps or any other product.
This depends on the Current Probes & Clamps individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Current Probes & Clamps and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Current Probes & Clamps.
Yes. We keep updating our stock frequently and if a product like Current Probes & Clamps is not in stock then we will let you know.