Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Products Found: 67

Showing Results For: LCR Meter Accessories

LCR Meter Accessories


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Keysight Technologies
Rohs Verified
U1780A, Keysight Technologies
4 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 45.61
Aim-TTi
LCR-BNC, Aim-TTi
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 106.02
Idealtek
ST5-IT-TB, Idealtek
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 42.40
Idealtek
ST-5S, Idealtek
6 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 320.45
ISO-TECH
LCR-13, ISO-TECH
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 141.36
Aoip Instrumentation
AMT 006, Aoip Instrumentation
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 232.96
Keysight Technologies
Rohs Verified
U1782B SMD Tweezer, Keysight Technologies
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 136.71
Idealtek
ST-5C, Idealtek
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 214.71
Aim-TTi
Rohs Verified
58212-0210, Aim-TTi
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 114.39
Rohde & Schwarz
Rohs Verified
HZ17, Rohde & Schwarz
Pre Order
Check Stock & Lead Times Packaging Options
Idealtek
ST5-IT-T, Idealtek
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 29.83
Peak Electronic Design
LLSm, Peak Electronic Design
8 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 18.37
Peak Electronic Design
SMD03m, Peak Electronic Design
6 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 22.43
ISO-TECH
Rohs Verified
RS_865-9827, ISO-TECH
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 86.80
Idealtek
ST5-IT-TSHP, Idealtek
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 42.40
Keysight Technologies
Rohs Verified
U1781A, Keysight Technologies
12 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 52.24
Rohs Verified
KWML 7420 / 1 / 150, Schutzinger
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 79.86
10 +
£ 71.88
25 +
£ 63.88
Showing
1 -

New Items
New items
16065C, Keysight Technologies

16065C, Keysight Technologies

The Keysight Technologies bias adapter supply a bias voltage of up to +/-40V to a DUT by connecting an external DC voltage source to this adapter. It is designed to operate specifically with the 4263A/B, 4268A and 4278A. 4 terminal pair connection 50 Hz to 1 MHz frequency
New items
TLKB1, BK Precision

TLKB1, BK Precision

The BK Precision 4 wire Kelvin clip test fixture minimizes the influence of the test lead resistance and improves measurement accuracy. Designed for BA6010 and BA6011
New items
LCX-K106, Rohde & Schwarz

LCX-K106, Rohde & Schwarz

The Rohde & Schwarz advanced analysis function, which is activated using a keycode, can be used for dynamic impedance measurements. In these sweep measurements, the impedance values are determined for a series of frequency values. It used for measuring impedance values It used for dynamic impedance measurements
New items
16034G, Keysight Technologies

16034G, Keysight Technologies

The Keysight Technologies 16034G this test fixture is designed for impedance evaluations of SMD. The minimum SMD size that this fixture is adapted to evaluate is 0.6 (L) x 0.3 (W) [mm]. Open and short compensations are recommended before measurement. When measuring above 3 MHz, load compensation is also recommended. Open compensation is performed by separating the high and the low electrodes from each other. The separation size should be equivalent to the DUT’s width Short compensation is performed placing the high and low electrodes in contact together Load compensation is performed by using the furnished 100 Ω SMD chip resistor After performing open, short and load compensations, the DUT is inserted into the test fixture
New items
16048E, Keysight Technologies

16048E, Keysight Technologies

The Keysight Technologies 16048E test leads extend the measurement port with a 4-Terminal Pair configuration. It is provided with a BNC female connector board to allow the attachment of user-fabricated test fixtures. Cable length compensation is recommended before measurement Set the instrument’s cable length compensation function to 4 m
New items
16089C, Keysight Technologies

16089C, Keysight Technologies

The Keysight Technologies 16089C this test fixture makes it possible to measure odd-shaped components that cannot be measured with conventional fixtures. It is equipped with two insulated Kelvin clips. Open and short compensations are recommended before measurement For open compensation, do not connect the Kelvin clips to anything Short compensation is performed by connecting the Kelvin clips together After performing open and short compensations, the DUT is held with the Kelvin clips
New items
P01295487, Chauvin Arnoux

P01295487, Chauvin Arnoux

The Chauvin Arnoux P012 is the set of 2 kelvin leads. The length of the kelvin lead is the 15 m and it have adjustable clamp connection. The current rating of the lead is the 200A. Colour of the kelvin lead is the red and black
New items
TL8KC1, BK Precision

TL8KC1, BK Precision

The BK Precision 4 terminal shielded Kelvin test lead is useful for measuring leaded capacitors, inductors, and resistors. When used with 880, the guarded lead reduces the effect of lead impedances and contact resistance thus minimizing measurement errors and improving accuracy especially in the lower impedance range. It is an included accessory with the model 880. Cable length is approximately 16 in
New items
ST-5S, Idealtek

ST-5S, Idealtek

Ideal-tek Smart Tweezers™ Colibri™ LCR meter and component identifier in a pair of Swiss precision-engineered tweezers: the tweezers are the premium ST-5S ( 841-8702 ) and its simplified economy version the ST-5C ( 841-8692 ); replacement tips are available ( 841-8705 ); precision bent tips ( 841-8709 ) and precision sharp tips ( 841-8718 ) are available separately. For measuring capacitance, resistance and inductance of electronic components Surface Mount Device (SMD) testing and identification Troubleshooting complex electronic systems
New items
16034H, Keysight Technologies

16034H, Keysight Technologies

The Keysight Technologies 16034H this test fixture is designed for impedance evaluations of array-type SMD. The minimum SMD size that this fixture is adapted to evaluate is 1.6(L) x 0.8(W) [mm]. Since the tip of the measurement electrodes are very thin and the device holder is extremely flat, the device can be shifted and the measurement electrodes can contact the each element of the array-type component. Open and short compensations are recommended before measurement When measuring above 3 MHz, load compensation is also recommended Open compensation is performed by separating the high and the low electrodes from each other The separation should be equivalent in size to the DUT’s width Short compensation is performed by placing the high and low electrodes in contact together Load compensation is performed by using the furnished 100 Ω SMD chip resistor After performing open, short and load compensations, the DUT is inserted into the test fixture
New items
ST5-IT-T, Idealtek

ST5-IT-T, Idealtek

Ideal-tek Smart Tweezers™ Colibri™ LCR meter and component identifier in a pair of Swiss precision-engineered tweezers: the tweezers are the premium ST-5S ( 841-8702 ) and its simplified economy version the ST-5C ( 841-8692 ); replacement tips are available ( 841-8705 ); precision bent tips ( 841-8709 ) and precision sharp tips ( 841-8718 ) are available separately. For measuring capacitance, resistance and inductance of electronic components Surface Mount Device (SMD) testing and identification Troubleshooting complex electronic systems
New items
SMD03m, Peak Electronic Design

SMD03m, Peak Electronic Design

Peak LCR40m Passive Component Analyser The LCR40m will automatically identify inductors, capacitors and resistors, measuring the main component value and other componant details (e.g coil inductance and dc resistance). The LCR40m is ideal for unmarked and surface mount designs. Automatic component identification Automatic test frequency selection Delayed or instant analysis (for hands free operation) Non volatile probe and test lead compensation Automatic ranging and scaling with real units displayed Auto and manual power-off Resistance range 1Ω to 2MΩ resolution 0.3Ω min, 0.6Ω typ accuracy ±1% ± 1.2Ω Capacitance range 0.5pF → 10000μF resolution 0.2pF min, 0.5pF typ accuracy ±1.5% ± 1.0pF Inductance range 1μH → 10H resolution 0.4μH min, 0.8μH typ accuracy ±1.5% ± 1.6μH Peak test voltage ±1.05V Peak test current +3.2mA Auto power on/off.
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like LCR Meter Accessories and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding LCR Meter Accessories or any other product.
This depends on the LCR Meter Accessories individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for LCR Meter Accessories and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including LCR Meter Accessories.
Yes. We keep updating our stock frequently and if a product like LCR Meter Accessories is not in stock then we will let you know.