Minimum Focus Distance:
15 (Thermal Lens) cm, 46 (Visual Lens) cm
Dimensions:
170 x 122 x 277mm
Temperature Measurement Range:
-20 → +600 °C
Focus Type:
Manual
Visual Camera:
Yes
Width:
122mm
Vertical Detector Resolution:
210pixel
Maximum Focus:
∞
Detector Resolution:
280 x 210pixel
Supplied Software:
Fluke SmartView
Battery Level Indicator:
Yes
Accuracy:
±2 %, ±2 °C
Display Resolution:
640 x 480pixel
Field of View H x V:
23 x 17°
Horizontal Detector Resolution:
280pixel
Model Number p:
TI29
Model Number:
TI29
Horizontal Display Resolution:
640pixel
Vertical Display Resolution:
480pixel
Maximum Temperature Measurement:
+600 °C
Auto Capture on Camera:
No
Horizontal Field of View:
23°
Minimum Focus:
15 (Thermal Lens) cm, 46 (Visual Lens) cm
Spatial Resolution IFOV:
1.43mrad
Display Size:
3.6in
Image Enhancement:
IR-Fusion
Vertical Field of View:
17°
Image Storage:
SD Card
Length:
170mm
Calibrated:
RSCAL
Interface Type:
USB
Interchangeable Lens:
Yes
Emissivity:
0.10 → 1.00
Thermal Sensitivity:
≤0.05 @ 30 °С
Voice Recorder:
Yes
Weight:
1.05kg
Other Built-in Measurements:
None
Radiometric Video on Camera:
No
Dimensions L x W x D:
277 x 122 x 170mm
Refresh Rate:
9Hz
Height:
277mm
Best Temperature Measurement Accuracy:
±2 °C
Field of View:
23 x 17°
Storage Media:
SD Card
This is Ti29 Thermal Imaging Camera Temperature Measurement Range: -20 → +600 °C 280 x 210pixel manufactured by Fluke. The manufacturer part number is FLUKE-TI29 (EU/9). Moreover, it has a minimum 15 (thermal lens) cm, 46 (visual lens) cm focus distance . The given dimensions of the product include 170 x 122 x 277mm. It has about -20 → +600 °c temperature measurement range . Its focus type is manual . It has a visual camera yes . Furthermore, the product is 122mm wide. Moreover, it has a 210pixel of vertical detector resolution . The has maximum focus ∞ . Additionally, it has a detector resolution of 280 x 210pixel . It has an embedded Supplied Software like fluke smartview . It has a battery level indicator included yes . It provides high accuracy of ±2 %, ±2 °c. The product is designed with a standard 640 x 480pixel display resolution . It has 23 x 17° field of view H x V . In addition, 280pixel is the horizontal detector resolution of the product . While it has ti29 of model number. It has a model number ti29. With 640pixel horizontal display resolution . It is offered with 480pixel of vertical display resolution . Additionally, it has a maximum +600 °c temperature measurement . It has an auto capture on camera no . It has 23° of horizontal field of view . Moreover, it has a minimum focus factor of 15 (thermal lens) cm, 46 (visual lens) cm . It has a spatial resolution IFOV of 1.43mrad . It is tailored with a standard 3.6in size display . In addition, it has an image enhancement ir-fusion . It has a vertical field of view 17° . Whereas, it has a/an sd card image storage . Its accurate length is 170mm. It is calibrated rscal . It is a type of usb interface. Moreover, it offers an interchangeable lens yes . It has 0.10 → 1.00 emissivity . The product has ≤0.05 @ 30 °с thermal sensitivity . It has a voice recorder embedded yes . The typical product's weight is 1.05kg. In addition, it has none built-in measurements . Radiometric video on camera included no . Moreover, it has about 277 x 122 x 170mm dimensions L x W x D . With 9hz refresh rate . In addition, the height is 277mm. It has about ±2 °c best temperature measurement accuracy . It has view filed of 23 x 17°. It has a/an sd card of storage media .
Reviews
Don’t hesitate to ask questions for better clarification.