Number of Outputs:
1
Load Regulation:
±1 (10 to 100% Load) %, ±2 (0 to 10% Load) %
Isolation Voltage:
4kV ac
Standards Met:
ANSI/AAMI ES 60601-1, CB, CSA 22.2 No. 60601-1:2008, EN 55011, EN 55022, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61204-3, IEC 60601-1, IEC 60601-1-2, MIL-HDBK-217F, TUV, UL
Mounting Type:
Through Hole
Package:
DIP 24
Maximum Temperature:
+80°C
Series:
JHM
Input Voltage Range:
9 → 18 V dc
Length:
31.75mm
Railway Approved:
No
Isolated:
Yes
Width:
20.32mm
Depth:
10.4mm
Output Voltage:
12V dc
Medical Approved:
Yes
Minimum Temperature:
-40°C
Input Voltage Nominal:
12 V dc
Power Rating:
10W
Output Current:
833mA
HTSUS:
8504.40.9580
RoHS Status:
ROHS3 Compliant
Power (Watts):
10 W
Current - Output (Max):
833mA
Package / Case:
24-DIP Module, 7 Leads
Voltage - Input (Min):
9V
Type:
Isolated Module
Applications:
Medical
Voltage - Output 1:
12V
Voltage - Output 2:
-
Voltage - Output 3:
-
Efficiency:
88%
Voltage - Input (Max):
18V
Package:
Tube
Size / Dimension:
1.25" L x 0.80" W x 0.50" H (31.8mm x 20.3mm x 12.7mm)
standardLeadTime:
14 Weeks
Voltage - Isolation:
4 kV
Moisture Sensitivity Level (MSL):
1 (Unlimited)
Features:
OCP, OVP, SCP, UVLO
Mounting Type:
Through Hole
Series:
JHM (10W)
Operating Temperature:
-40°C ~ 80°C
Base Product Number:
JHM1012
Number of Outputs:
1
ECCN:
EAR99
This is manufactured by XP Power. The manufacturer part number is JHM1012S12. Additionally, the product is supplied with 1 outputs. Load Regulation - ±1 (10 to 100% load) %, ±2 (0 to 10% load) %. It has 4kv ac isolation voltage. The product complies with all safety standards, such as ansi/aami es 60601-1, cb, csa 22.2 no. 60601-1:2008, en 55011, en 55022, en 61000-4-2, en 61000-4-3, en 61000-4-4, en 61000-4-5, en 61000-4-6, en 61000-4-8, en 61204-3, iec 60601-1, iec 60601-1-2, mil-hdbk-217f, tuv, ul. The product is available in through hole configuration. It is shipped in dip 24 package . The product has +80°c maximum temperature. The product jhm, is a highly preferred choice for users. It has 9 → 18 v dc of input voltage range. Its accurate length is 31.75mm. The product is railway approved no . Isolated options - yes. Furthermore, the product is 20.32mm wide. The product comes in 10.4mm depth. Features a 12v dc output voltage. Medical Approval - yes. While its minimum temperature is -40°c. It has 12 v dc of nominal input voltage. Feature 10w of power rating. It carries 833ma output current. It is assigned with possible HTSUS value of 8504.40.9580. The product is rohs3 compliant. The product features power and watts of 10 w. The maximum product's output current is 833ma. Moreover, the product comes in 24-dip module, 7 leads. It offers 9v of minimum input voltage. It comes in isolated module configuration. The product is widely employed in medical. It has a 12v output voltage. It is a highly efficient product with an 88% of high efficiency. Its maximum input voltage is 18v. It is shipped in tube package . The product's diameters include 1.25" l x 0.80" w x 0.50" h (31.8mm x 20.3mm x 12.7mm). It has a long 14 weeks standard lead time. 4 kv of isolation voltage. Its typical moisture sensitivity level is 1 (unlimited). The splendid features of the product include ocp, ovp, scp, uvlo. The product jhm (10w), is a highly preferred choice for users. The product has -40°c ~ 80°c operating temperature range. Moreover, it corresponds to jhm1012, a base product number of the product. The product is designated with the ear99 code number.
Reviews
Don’t hesitate to ask questions for better clarification.