Isolation Voltage:
1.5kV ac
Minimum Temperature:
-40°C
Isolated:
Yes
Width:
40.6mm
Maximum Temperature:
+85°C
Load Regulation:
±0.5%
Standards Met:
CE Certified, EN50121-3-2, EN50155, EN55011, EN60950-1:2006+A12:2011, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, LVD, MIL-HDBK-217F, TUV
Railway Approved:
Yes
Number of Outputs:
1
Output Voltage Adjustment Range:
-10 → +10%
Package:
2 x 1.6 in
Length:
50.8mm
Medical Approved:
No
Output Current:
3.35A
Mounting Type:
Through Hole
Series:
RDC40
Input Voltage Range:
55 → 176 V dc
Depth:
10.16mm
Output Voltage:
12V dc
Input Voltage Nominal:
110 V dc
Power Rating:
40W
Base Product Number:
RDC40110
HTSUS:
8504.40.9580
RoHS Status:
ROHS3 Compliant
Power (Watts):
40 W
Current - Output (Max):
3.35A
Package / Case:
6-DIP Module
Voltage - Input (Min):
55V
Type:
Isolated Module
Applications:
ITE (Commercial), Railway
Voltage - Output 1:
12V
Voltage - Output 2:
-
Voltage - Output 3:
-
Efficiency:
89%
Voltage - Input (Max):
176V
Control Features:
Enable, Active High
Package:
Tube
Size / Dimension:
2.00" L x 1.60" W x 0.42" H (50.8mm x 40.6mm x 10.7mm)
standardLeadTime:
22 Weeks
Voltage - Isolation:
1.5 kV
Moisture Sensitivity Level (MSL):
1 (Unlimited)
Features:
Remote On/Off, OCP, OTP, OVP, SCP, UVLO
Mounting Type:
Through Hole
Series:
RDC (40W)
Operating Temperature:
-40°C ~ 85°C
Standard Number:
62368-1
Number of Outputs:
1
ECCN:
EAR99
This is manufactured by XP Power. The manufacturer part number is RDC40110S12. It has 1.5kv ac isolation voltage. While its minimum temperature is -40°c. Isolated options - yes. Furthermore, the product is 40.6mm wide. The product has +85°c maximum temperature. Load Regulation - ±0.5%. The product complies with all safety standards, such as ce certified, en50121-3-2, en50155, en55011, en60950-1:2006+a12:2011, en61000-4-2, en61000-4-3, en61000-4-4, en61000-4-5, en61000-4-6, en61000-4-8, lvd, mil-hdbk-217f, tuv. The product is railway approved yes . Additionally, the product is supplied with 1 outputs. It has -10 → +10% of output voltage adjustment range. It is shipped in 2 x 1.6 in package . Its accurate length is 50.8mm. Medical Approval - no. It carries 3.35a output current. The product is available in through hole configuration. The product rdc40, is a highly preferred choice for users. It has 55 → 176 v dc of input voltage range. The product comes in 10.16mm depth. Features a 12v dc output voltage. It has 110 v dc of nominal input voltage. Feature 40w of power rating. Moreover, it corresponds to rdc40110, a base product number of the product. It is assigned with possible HTSUS value of 8504.40.9580. The product is rohs3 compliant. The product features power and watts of 40 w. The maximum product's output current is 3.35a. Moreover, the product comes in 6-dip module. It offers 55v of minimum input voltage. It comes in isolated module configuration. The product is widely employed in ite (commercial), railway. It has a 12v output voltage. It is a highly efficient product with an 89% of high efficiency. Its maximum input voltage is 176v. Possible control features include enable, active high. It is shipped in tube package . The product's diameters include 2.00" l x 1.60" w x 0.42" h (50.8mm x 40.6mm x 10.7mm). It has a long 22 weeks standard lead time. 1.5 kv of isolation voltage. Its typical moisture sensitivity level is 1 (unlimited). The splendid features of the product include remote on/off, ocp, otp, ovp, scp, uvlo. The product rdc (40w), is a highly preferred choice for users. The product has -40°c ~ 85°c operating temperature range. Standard number include: 62368-1. The product is designated with the ear99 code number.
Reviews
Don’t hesitate to ask questions for better clarification.