16194, Merlin Gerin

V'clic indicator lights V'clic indicator lights are used to produce illuminated signals. Installed under Bar'clic combs or before a Distri'clic XE splitter. Removal with comb installed. Standards EN 60947-5-1
New items
23158, Merlin Gerin

23158, Merlin Gerin

ID'clic XP 30mA two-pole differential switches ID'clic differential switches, protected against untimely tripping. Used for protecting "blue tariff" installations. Supply voltage 230Vac. Standard AC graphs, for detecting default current with continuous components or Asi for improved immunity. Technical specifications Type: Two-pole Sensitivity: 30mA Connection ≤ 40A: 10mm² = 63A: 16mm² Graph type AC, A and Asi Colour: RAL 9003 white Standards NF EN 61008
New items
16655, Merlin Gerin

16655, Merlin Gerin

MIN'clic timer "Blue Rate" modular timer. Opens and closes the contact according to a time that can be set between 1 and 7 minutes at 50 Hz (48 seconds to 5.6 minutes at 60 Hz). This timer has a 2-position switch on the front panel: automatic operation: timer (after 20 s of operation, pressing the push-button restarts the timer). forced operation: constant lighting. Time can be set in 15-second intervals using the thumb wheel. Analogue
New items
13155, Merlin Gerin

13155, Merlin Gerin

Kaedra weatherproof enclosures for modular switchgear and sockets Single row weatherproof modular enclosures, can accommodate 5 to 13 modules of 18 mm, and 2 to 4 sockets. Enclosure in light grey RAL 7035 and transparent green door. Each enclosure includes: set of snap-on base/front face hinges, marker kit, wire strap, terminal support, terminal, divisible blanking plates, functional plates and Class 2 protective cap. Stainless steel screws ref. Merlin Gerin Dimensions (mm) H x W x depth no. of rows no. of modules Number of openings. rated current 13962 460 x 138 x 178 1 5 2 63 A 13963 460 x 236 x 178 1 8 4 63 A 13964 335 x 340 x 178 1 13 3 63 A Main characteristics Protection index: IP65 / IK09 Class: II (full insulation) Operating temperature: -25°C to +60°C
New items
19067, Merlin Gerin

19067, Merlin Gerin

Accessories for NG125 Circuit Breakers Range of electrical accessories including trip units and contacts, as well as accessories for connection, comb busbars, tooth ends and 100 A flexible connections. MN voltage release trip unit. MNs (0.5 s) undervoltage trip unit. MNx trip unit for opening BP. MX + OF shunt trip. Auxiliary contact O/C + O/C Auxiliary contact O/C + SD
New items
16187, Merlin Gerin

16187, Merlin Gerin

BP'clic push-buttons Push-buttons for mounting onto DIN rails. For pulse control. 2- or single-pole versions available. Indicator light: Led Consumption: 0.3 W Service life: 100000 hours Mechanical endurance: 30000 operations Operating voltage: 250 Vac Rating: 20 A Standards EN 60669-1 and EN 60947-5-1
New items
28621, Merlin Gerin

28621, Merlin Gerin

NG160 circuit breakers 3- and 4-pole circuit breakers specially designed to operate upstream of Multi 9 modular equipment. Enhanced breaking capacity of downstream devices up to 25 kA by descent. Rated In current 40 °C 160 A Ue rated operating voltage 500 Vac, 50 / 60 Hz Number of cycles (O - C) 10000 Ir thermal protection fixed threshold 1 In Dimensions (H x L x D) in mm 120 x 90 x 82.5 (3-pole) 120 x 120 x 82.5 (4-pole) Standards IEC 60947-2
New items
23161, Merlin Gerin

23161, Merlin Gerin

ID'clic XP 30mA two-pole differential switches ID'clic differential switches, protected against untimely tripping. Used for protecting "blue tariff" installations. Supply voltage 230Vac. Standard AC graphs, for detecting default current with continuous components or Asi for improved immunity. Technical specifications Type: Two-pole Sensitivity: 30mA Connection ≤ 40A: 10mm² = 63A: 16mm² Graph type AC, A and Asi Colour: RAL 9003 white Standards NF EN 61008
New items
16407, Merlin Gerin

16407, Merlin Gerin

TL'clic remote control switches TL'clic switches are designed to remotely control single-phase circuits. They can be used in conjunction with ID'clic single-phase circuit breakers or differential breakers. Connectors ensure a fast, safe electrical connection to the line protection circuit breaker. The connector can be disassembled for wiring to plug-in ID'clic XE terminals. Supply voltage 230 Vac.
New items
16726, Merlin Gerin

16726, Merlin Gerin

1P+N D'clic XE circuit breakers Range of plug-in circuit breakers for assembly on Distri'clic XE splitters. Control and protection of single-phase circuits downstream of the connecting circuit breaker, for "blue tariff". Standard C graph. The magnetic circuit breakers work between 5 and 10In. Supply voltage 230Vac. Breaking capacity 3kA according to EN 60989. Standards NF EN 60898 Standards NF EN 60898
New items
13102, Merlin Gerin

13102, Merlin Gerin

Connection circuit breakers series DB90 LV subscriber circuit breakers for power up to 36kVA. Instantaneous differential models: Protects people from indirect contact and equipment from isolation faults. Selective differential models: Ensures total selectivity with high sensitivity (30mA) differential devices installed downstream so that only the start with an isolation fault is turned off. Enables installation of a lightning arrester immediately upstream of the circuit breaker with out risk of untimely tripping of the latter. Enables service quality requirements to be taken into account by certain receivers (freezer, computer equipment etc.). Meets EDF requirements. Differential devices with test button. Standard: NFC 62411 Sensitivity: 500mA ref. Merlin Gerin rating (A) voltage (Vac) housing Selective differentials 13120 15 / 30 / 45 250 Double pole Instantaneous differentials 13100 15 / 30 / 45 250 Double pole 13106 30 / 45 / 60 250 Double pole 13102 10 / 15 / 20 / 25 / 30 440 Four pole 13103 30 / 40 / 50 / 60 440 Four pole
New items
16157, Merlin Gerin

16157, Merlin Gerin

ID'clic XE 30 mA two-pole differential switches ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters; Used for protection of "blue tariff" installations. Supply voltage 230 Vac. Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity. Technical specifications Type: Two-pole Sensitivity: 30mA Connection ≤ 40A: 10mm² = 63A: 16mm² Graph type AC, A and Asi Colour: RAL 9003 white Standards NF C 15-100