Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Keithley Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Keithley


Categories For Keithley




New Items
New items
2601B-PULSE-CA1, Keithley

2601B-PULSE-CA1, Keithley

The Keithley instrument BNC-to-BNC Cable Kit is a set of four 1.2 m BNC-to-BNC cables having 50 O impedance. It has rated voltage up to 40 V and rated current 11 A. These cables are available in black colour. These cables are intended to make the FORCE HI and LO connections for a 4-wire measurement Operating temperature range is from -40°C to +85 °C
New items
2110, Keithley

2110, Keithley

Keithley 2110 5-digit Dual-display Digital Multimeter The Keithley 2110 5-digit dual-display digital multimeter is optimized for a variety of general-purpose system and bench design applications. Compared with other leading 5-digit DMMs, the 2110 offers excellent throughput (up to 10x faster), accuracy (up to 2x better DC voltage accuracy), value and integration flexibility. Measurement capabilities include DC voltage up to 1000V and current up to 10A, AC voltage up to 750V and current up to 10A, 2- and 4-wire resistance up to 100 mega-ohms, temperature, frequency (10Hz–300kHz) and period, and capacitance (1 nanofarad to 100 microfarad ranges). Mathematical functions and diode and continuity test functions are included. Programmable A-D converter and filter settings help optimise the 2110's signal-to-noise ratio to improve measurement accuracy. At the fast 4-digit setting, it takes up to 50,000 readings/second. The instrument's dual display can show the results from two measurements (e.g. DC voltage and temperature) simultaneously, so that users can monitor temperature fluctuations without interrupting other measurements. An intuitive front panel facilitates use of the 2110 by students, without sacrificing measurement performance or flexibility. System features include external triggering and a built-in reading buffer. Keithley
New items
2200-30-5, Keithley

2200-30-5, Keithley

Keithley Programmable DC Power Supplies Series 2200 The Keithley Series 2200 family combines superior voltage and current output accuracy at a cost-effective price, flexible operation, and features designed to enhance ease of use in a variety of device characterization or test applications. The voltage output accuracy of Series 2200 power supplies is specified at 0.03%; current output accuracy is 0.05%. Both specifications better those of competitive general-purpose supplies. High output (1mV) and measurement (0.1mA) resolution make the 2200 Series well-suited for characterizing low power circuits and devices in applications such as measuring idle mode and sleep mode currents (for energy efficiency). Remote sense terminals on the back panel and less than 5mVp-p noise help ensure that the voltage programmed is the voltage that the supply actually outputs. A dual-line display shows both the programmed values and actual outputs for a continuous indication of the status of the power delivered to the load. 40 onboard memory locations for storing frequently used test setups for later recall and reuse Built-in list mode function supports the programming and storage of up to seven custom test sequences of up to 80 steps Saved sequences can be triggered to run manually (front panel keys), automatically (via external trigger) or by using programmable interface commands Current limit setting function controls the level of current that can flow into the DUT Programmable voltage limit value prevents the supply from outputting excessive voltage Programmable over-voltage function causes output to drop to less than 1V if the over-voltage limit is reached Programmable timer can be used to turn off the output after a specified time interval, so that tests can be pre-programmed to run unattended Direct-entry numeric keypad located on the front panel Rotary knob with adjustable step size simplifies studying the response of ...
New items
KTTI-RS232, Keithley

KTTI-RS232, Keithley

The Keithley KTTI-RS232 Communication and Digital I/O Accessory provides instruments with an accessory card slot with an RS-232 interface. The card provides six independently configurable digital input/output lines that can be used to control external digital circuitry for example, a handler that is used to perform binning operations. DB-9 female connector Compliance with CE and NRTL
New items
3730, Keithley

3730, Keithley

The Keithley two-pole, 6 row by 16 column matrix card. It can connect up to six differential instrument channels to any combination of 16 DUTs. Any row can be connected to the series 3700A mainframe backplane by using the analogue backplane connection relays. This allows for easy matrix column expansion. A matrix of up to 6 rows by 96 columns can be supported within a single model 3706A mainframe. Analog backplane connection relays provide easy column expansion Relay closures stored in on-board memory Latching electromechanical relays
New items
4299-9, Keithley

4299-9, Keithley

The Keithley dual fixed rack-mount kit for 2U graphical instruments contains all the hardware you need to install two adjacent 2U graphical instruments in a standard 19-inch equipment rack. 1U is a standard vertical spacing that is equal to 4.45 cm
New items
7078-TRX-TBC, Keithley

7078-TRX-TBC, Keithley

The Keithley bulkhead connector with cap is a chassis mount 3 lug female triax connector for applications such as text fixtures. A cap is provided to keep an unused connector to clean. Maximum working current 1A peak Operating environment 0 to 50 °C
New items
237-TRX-T, Keithley

237-TRX-T, Keithley

The Keithley Three-Slot Triaxial Tee Adapter to connect multiple inputs to SMUs and electrometers. It also allows connection of external feedback elements to electrometers. Strong design Reliable
New items
2600-ALG-2, Keithley

2600-ALG-2, Keithley

The Keithley triax cable that is terminated with a 3-slot male triax connector on one end and alligator clips on the other end. This product is intended for use only by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Simple design Low noise
New items
3730-ST, Keithley

3730-ST, Keithley

The Keithley Screw terminal panel is an accessory which provides easy removable connections for Matrix Card. It is for use with high density matrix card. Simplified connections Detachable
New items
4299-2, Keithley

4299-2, Keithley

The Keithley Dual-Unit Rack-Mount Kit contains the hardware required to mount two half-rack instrument in a standard rack. Typical installation is for two Series 2600A or 2600B System Source Meter instruments or one Series 2600A or 2600B instrument with another half-rack instrument. Heavy duty kit Flat bladed screwdriver or cage nut installation tool