Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
GILGEN Muller & Weigert Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For GILGEN Muller & Weigert




New Items
New items
KBR18 75/1A 1VA Kl.3, GILGEN Muller & Weigert

KBR18 75/1A 1VA Kl.3, GILGEN Muller & Weigert

The GILGEN Muller & Weigert compact split-core current transformer for primary nominal currents from 50 A up to 250 A. It is has unbreakable plastic housing made of grey polycarbonate. It has isolation class E Flame resistant
New items
KBU812 1500/5A 15VA Kl.1, GILGEN Muller & Weigert

KBU812 1500/5A 15VA Kl.1, GILGEN Muller & Weigert

The GILGEN Muller & Weigert split-core current transformer for primary nominal currents from 250 A up to 1500 A. It is has unbreakable plastic housing made of grey polycarbonate. It has isolation class E Flame resistant
New items
FASK 150 100mV/kA 10m, GILGEN Muller & Weigert

FASK 150 100mV/kA 10m, GILGEN Muller & Weigert

The GILGEN Muller & Weigert rogowski coil having window size of 150mm and coil length of 525mm. It has maximum measurable current up to 100mV/kA. It has working temperature from -30 to +80°C
New items
9625500000, GILGEN Muller & Weigert

9625500000, GILGEN Muller & Weigert

Moving iron measuring tools, AC current and voltage measurement EQN / EQB moving-iron instruments for measuring alternating current and voltage Measurement accuracy: Class 1.5 With front zero-point regulator Overload range of 100% with current meters for start-up bridging Protection rating IP52 Incl. pre-mounted, replaceable scale Incl. mounting frame, terminal cover
New items
EQB72 MB: 500V         SCALA: 500V, GILGEN Muller & Weigert

EQB72 MB: 500V SCALA: 500V, GILGEN Muller & Weigert

Moving iron measuring tools, AC current and voltage measurement EQN / EQB moving-iron instruments for measuring alternating current and voltage Measurement accuracy: Class 1.5 With front zero-point regulator Overload range of 100% with current meters for start-up bridging Protection rating IP52 Incl. pre-mounted, replaceable scale Incl. mounting frame, terminal cover 48 x 48 mm 72 x 72 mm 96 x 96 mm Measurement range Scale For converters 202-940 202-811 392-8614 1.5 / 3 Aac 0 → 1.5 / 3 A n/a 202-451 202-833 392-8563 10 / 20 Aac 0 → 10 / 20 A n/a 201-969 202-805 392-8456 25 / 50 Aac 0 → 25 / 50 A n/a - 202-827 392-8434 40 / 80 Aac 0 → 40 / 80 A n/a 202-473 201-896 392-9128 5 / 10 Aac 0 → 50 / 100 A 50 / 5 A 202-467 201-880 392-9718 5 / 10 Aac 0 → 100 / 200 A 100 / 5 A 202-445 202-782 392-9724 5 / 10 Aac 0 → 200 / 400 A 200 / 5 A 204-378 202-776 392-8462 5 / 10 Aac 0 → 250 / 500 A 250 / 5 A - 201-903 392-8204 10 Vac 0 → 10 V n/a - - 392-8305 30 Vac 0 → 30 V n/a - 202-798 392-8276 60 Vac 0 → 60 V n/a 202-495 201-925 392-8529 250 Vac 0 → 250 V n/a 202-489 201-919 392-8478 500 VAC 0 → 500 V n/a Standards DIN 43700; EN 61010; VDE 0411; IEC 1010
New items
9642000000B, GILGEN Muller & Weigert

9642000000B, GILGEN Muller & Weigert

96 x 96 mm permanent-magnet moving-coil instruments for measuring current and voltage DQB permanent-magnet moving-coil instruments measure direct currents If a meter rectifier is used, the average value of a rectified alternating current can also be determined Measurement accuracy: Class 1.5 (= max. error 1.5% of final value) Front: 96 x 96 mm For 92 x 92 mm standardised front panel cut-out (up to 6 mm thick) With front zero-point regulator Protection rating IP52 Incl. pre-mounted, replaceable scale Incl. mounting frame, terminal cover Measuring range expanded with shunt 60 mV Stock no. Measurement range Scale For shunt 392-8298 10 V 0 → 10 V - 392-8658 40 V 0 → 40 V - 392-8642 60 V 0 → 60 V - 392-8585 500 V 0 → 500 V - 392-8428 20 mA 0 → 100% - 392-9106 20 mA 0 → 20 mA - 392-9134 0 / 4 → 20 mA 0 → 100% - 392-8557 0 / 4 → 20 mA 0 → 20 mA - 392-8620 15 A 0 → 15 A - 392-8591 25 A 0 → 25 A - 392-9702 60 mV 0 → 25 A 60 mV, 25 A 392-9140 60 mV 0 → 40 A 60 mV, 40 A 392-8636 60 mV 0 → 100 A 60 mV, 100 A 392-8507 60 → 0 → 60 mV 25 → 0 → 25 A 60 mV, 25 A Standards DIN 43700; EN 61010; VDE 0411; IEC 1010 Moving Coil DC Meters
New items
5740000005, GILGEN Muller & Weigert

5740000005, GILGEN Muller & Weigert

Compact Alphanumeric Data Printer – IPP144-40G DIN standard 72x144mm housing Long life, fixed head, thermal printing mechanism Alphanumeric text or graphics Multi-standard serial data interface 10s to 24h Print Interval Timer Out-of-paper alarm LED Uses “document proof” thermal paper with 10 year storage life, see 623-013 IPP144-40G IPP144-40GE Interface RS232C, RS-485, active or passive 20mA TTY current loop. Baud rates 110-38400. Optional CTS-RTS handshake. Address 00 to 31. All menu selectable. Input buffer 16kB, 9-way D connector. RS232C, RS422, RS-485, active or passive 20mA TTY current loop. Baud rates 110-38400. Optional CTS-RTS handshake. Address 00 to 31. All menu selectable. Input buffer 16kB, 9-way D connector. USB (4-way type B) Set-up Menu - - Connections - - Input Buffer/Text Memory CMOS-RAM stores up to 15 40 character texts CMOS-RAM stores up to 15 40 character texts Print Interval Timer Up to 24hrs in 10s intervals Up to 24hrs in 10s intervals Print Resolution 576 dots/line (8 dots/mm) 576 dots/line (8 dots/mm) Print Head Life 10⁶ line impulses 10⁶ line impulses Character Height 2.4mm (40 characters per line) 2.4mm (40 characters per line) Character Set 255 international IBM character, English (ASC11 7-bit), German, French, Spanish 255 international IBM character, English (ASC11 7-bit), German, French, Spanish Swedish, Danish, Norwegian Swedish, Danish, Norwegian Characters Per Line 8/16/40 (Print width 72mm) 8/16/40 (Print width 72mm) Print Format Normal, Inverse or 90̊ rotation Normal, Inverse or 90̊ rotation Paper Type Thermal paper. PTB tested to DIN "document proof" standards Thermal paper. PTB tested to DIN "document proof" standards Paper Width 80mm 80mm Paper Roll Length 14m 14m
New items
DACT 60 600:1 4-polig, GILGEN Muller & Weigert

DACT 60 600:1 4-polig, GILGEN Muller & Weigert

The GILGEN Muller & Weigert series core balance transformers in connection with our earth fault relay -ELR are designed for the detection of residual currents. Pollution degree III Protection class housing IP40
New items
SUSK4 1+1+1+1/1A 15VA Kl.0,5, GILGEN Muller & Weigert

SUSK4 1+1+1+1/1A 15VA Kl.0,5, GILGEN Muller & Weigert

The GILGEN Muller & Weigert summation current transformer having current rating of 1A. High quality Snap on mounting
New items
EQB48 MB: WDL.5/10A  SCALA: 0-100/200A, GILGEN Muller & Weigert

EQB48 MB: WDL.5/10A SCALA: 0-100/200A, GILGEN Muller & Weigert

Moving iron measuring tools, AC current and voltage measurement EQN / EQB moving-iron instruments for measuring alternating current and voltage Measurement accuracy: Class 1.5 With front zero-point regulator Overload range of 100% with current meters for start-up bridging Protection rating IP52 Incl. pre-mounted, replaceable scale Incl. mounting frame, terminal cover 48 x 48 mm 72 x 72 mm 96 x 96 mm Measurement range Scale For converters 202-940 202-811 392-8614 1.5 / 3 Aac 0 → 1.5 / 3 A n/a 202-451 202-833 392-8563 10 / 20 Aac 0 → 10 / 20 A n/a 201-969 202-805 392-8456 25 / 50 Aac 0 → 25 / 50 A n/a - 202-827 392-8434 40 / 80 Aac 0 → 40 / 80 A n/a 202-473 201-896 392-9128 5 / 10 Aac 0 → 50 / 100 A 50 / 5 A 202-467 201-880 392-9718 5 / 10 Aac 0 → 100 / 200 A 100 / 5 A 202-445 202-782 392-9724 5 / 10 Aac 0 → 200 / 400 A 200 / 5 A 204-378 202-776 392-8462 5 / 10 Aac 0 → 250 / 500 A 250 / 5 A - 201-903 392-8204 10 Vac 0 → 10 V n/a - - 392-8305 30 Vac 0 → 30 V n/a - 202-798 392-8276 60 Vac 0 → 60 V n/a 202-495 201-925 392-8529 250 Vac 0 → 250 V n/a 202-489 201-919 392-8478 500 VAC 0 → 500 V n/a Standards DIN 43700; EN 61010; VDE 0411; IEC 1010
New items
DACT 120 600:1 4-polig, GILGEN Muller & Weigert

DACT 120 600:1 4-polig, GILGEN Muller & Weigert

The GILGEN Muller & Weigert series core balance transformers in connection with our earth fault relay -ELR are designed for the detection of residual currents. Pollution degree III Protection class housing IP40
New items
KBR44 400/1A 5VA Kl.1, GILGEN Muller & Weigert

KBR44 400/1A 5VA Kl.1, GILGEN Muller & Weigert

The GILGEN Muller & Weigert compact split-core current transformer for primary nominal currents from 100 A up to 600 A. It is has unbreakable plastic housing made of grey polycarbonate. It has isolation class E Flame resistant