Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
DTS Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For DTS


Categories For DTS




New Items
New items
XQF400P, DTS

XQF400P, DTS

Ex de XF Floodlight The XF Series of hazardous area Ex d Floodlight fitting from DTS has a robust design and is ideal for many hazardous areas, whether it is oil, gas or marine. The XF ATEX Floodlights come with a variety of fixings, allowing them to be mounted onto many types of structures, including poles. This range of floodlights is available with a choice of HP Sodium or Metal Halide lamps. Floodlight with galvanised steel flat mounting bracket Compact, lightweight and robust Ferromagnetic ballast 220 V 60 Hz Manufactured to be Ex d but has Ex e integral junction box for easy installation Excellent photometric properties, wide or narrow beam Internationally recognised Supplied with lamp installed and cable gland Approvals LCIE 00 ATEX 6019X IECEx LCI 11-0062X Ex II 2 G Ex de IIB T3 Gb for ≤ -20°C to ≤ +40°C Ex de IIB T2 Gb for ≤ -20°C to ≤ +60°C IEC 60529 (2001) IP66 Supplied with Lamp installed, one nickel-plated brass M20 stopping plug and one cable gland M20 for non armoured cable (10-16mm)
New items
EVNL240-0000, DTS

EVNL240-0000, DTS

LED fixture, 5 wire loop - 59W - universal electronic driver 100-254V 50-60Hz and LED module - includes - one nylon M20 cable gland Dia 6-12mm, two M20 nylon stopping plugs and two zinc-plated steel brackets for ceiling mounting (V015) - LCIE 15ATEX 1010X, IECEx LCIE 15 0018X, II 3 GD, Ex nA IIC T4 Gc (-40C to -60C), Ex nA IIC T5 Gc (-40C to -25C), Ex tc IIIC T85Dc (-40C to -60C), Ex tc IIIC T65Dc (-40C to -35C) EVNL Linear LED fitting 5 wires Glass Diffuser Suitable for use in Zones 1, 2, 21, 22
New items
EVN240, DTS

EVN240, DTS

Zone 2 & 22 Ex nR The EVN Series of hazardous area Ex nR fluorescent luminaries from DTS, is designed for use in Zone 2 and 22, making it ideal for hazardous areas affected by dust. The EVN luminarie combines high quality with a large range of features. Electronic ballast 110- 260V 50/60Hz Main body constructed of a GRP for high impact strength Fluorescent fitting 5 wire Loop Polycarbonate diffuser to resist harsh and corrosive environments All components mounted on hinged and removable gear tray Easy access for installation and maintenance Lamp not included Approvals EN60079-0, 60079-15, EN61241-1 Ex II 3 G Ex nR IIC T4 Gb for ≤ -40°C to ≤ +60°C Ex nR IIC T6 Gb for ≤ -40°C to ≤ +35°C Ex II 3 D Ex tc IIIC T100°C to T135°C Dc IP6x IEC 60529 (2001) IP66 Supplied with One nylon M20 cable gland (6-12mm), two M20 nylon plugs, two zinc plated steel brackets for ceiling mounting (V015)
New items
XQF250P, DTS

XQF250P, DTS

Ex de XF Floodlight The XF Series of hazardous area Ex d Floodlight fitting from DTS has a robust design and is ideal for many hazardous areas, whether it is oil, gas or marine. The XF ATEX Floodlights come with a variety of fixings, allowing them to be mounted onto many types of structures, including poles. This range of floodlights is available with a choice of HP Sodium or Metal Halide lamps. Floodlight with galvanised steel flat mounting bracket Compact, lightweight and robust Ferromagnetic ballast 220 V 60 Hz Manufactured to be Ex d but has Ex e integral junction box for easy installation Excellent photometric properties, wide or narrow beam Internationally recognised Supplied with lamp installed and cable gland Approvals EN60079-0, 60079-1, 60079-7 LCIE 00 ATEX 6019X IECEx LCI 11-0062X Ex II 2 G, Ex de IIB T3 Gb for ≤ -20°C to ≤ +40°C Ex de IIB T2 Gb for ≤ -20°C to ≤ +60°C IEC 60529 (2001) IP66 Supplied with Lamp installed, one nickel-plated brass M20 stopping plug and one cable gland M20 for non armoured cable (10-16mm)
New items
EVS240EMA, DTS

EVS240EMA, DTS

Emergency Hazardous Fitting, Zone 1, 2, 21 & 22 Ex-e The EVS-EMA Series from DTS is an emergency lighting hazardous area Ex e fluorescent luminaries, is designed for use in Zone 1, 2, 21, and 22 areas, allowing the same emergency luminaries to be used across the whole of a hazardous area site at the same time meeting the requirements of the evacuation standards. The EVS-EMA ATEX luminaries combine high quality with a large range of features. Main body constructed of a GRP for high impact strength Polycarbonate diffuser to resist harsh and corrosive environments Electronic ballast 220- 240V 50/60Hz Battery duration 3 hours Emergency fluorescent fitting with automatic test 5 wire Loop Clear LED for easy visual battery inspection Automatic switch off upon opening for safe maintenance All components mounted on hinged and removable gear tray Easy access for installation and maintenance Lamp not included Approvals EN60079-.0, 60079-1, 60079-5, 60079-7, 61241-1 LCIE 11 ATEX 3065X IEC Ex LCI 11,0053X Ex II 2 G Ex de IIC T4 Gb for ≤ -40°C to ≤ +60°C Ex de IIC T5 Gb for ≤ -40°C to ≤ +35°C Ex II 2 D, Ex tb IIIC T85°C Db IP6x IEC 60529 (2001) IP66 Supplied with One nylon M20 cable gland cable (6-12mm), two M20 nylon plugs & two zinc plated steel brackets for ceiling mounting (V015) Emergency Light Fittings There are two basic types of emergency lighting luminaires - maintained and non-maintained. Maintained,These luminaires have the advantage of being able to be switched between the maintained function (lamp illuminated at all times) and non-maintained (lamp off until power supply fails), making them ideal for applications such as corridors, workshops and permanently illuminated emergency exit signs.The maintained luminaires also have the facility of being switched in banks of up t...
New items
XFF240, DTS

XFF240, DTS

Tubular fluorescent fitting, Zone 1, 2, 21 & 22 Ex d The XFF Series of hazardous area Ex d tubular fluorescent luminarie from DTS, is designed for use in Zone 1, 2, 21 and 22, areas, allowing the same luminaries to be used across a hazardous area site, whether it is oil and gas or food and beverage. The XFF ATEX luminarie combines high quality with a large range of features. Tubular fluorescent fitting - Polycarbonate Manufactured from marine grade aluminum Finishing Yellow offshore All components mounted on slide out gear tray Easy access for installation and maintenance Automatic switch off upon opening for safe maintenance Standard components used inside the body allowing reduced maintenance costs Electronic ballast 220 - 240V 50/60Hz No lamp included Approvals INERIS 11 ATEX 0051X Ex II 2 G Ex d IIC T6 Gb for ≤ -20°C to ≤ +55°C Ex II 2 D Ex tb IIIC T80°C Db IP66 Supplied with One 3/4 in NPT nickel-plated brass cable gland for non armoured cable (12-16 mm), one 3/4 in NPT nickel-plated brass stopping plug and two zinc plated steel articulated brackets for ceiling mounting (D023)
New items
XFFL220V-00000, DTS

XFFL220V-00000, DTS

Tubular LED fixture - Glass tube - 23W - universal electronic driver 100-254V 50-60Hz and LED module - Offshore grade yellow paint RAL 1003 - includes - one 3/4 NPT nickel plated brass cable gland for non-armoured cable diameter 6-12 mm, one nickel plated 3/4 NPT stopping plug and two zinc-plated steel articulated brackets for ceiling mounting (D023) - INERIS 13 ATEX 0050X, II 2 GD, Ex d IIC T6 Gb , Ex tb IIIC T70C Db (-20C to 55C) XFFL Tubular LED fitting 5 wires Glass Diffuser Equipped with 1 cable gland & 1 plug Suitable for use in Zones 1, 2, 21, 22
New items
XFF220, DTS

XFF220, DTS

Tubular fluorescent fitting, Zone 1, 2, 21 & 22 Ex d The XFF Series of hazardous area Ex d tubular fluorescent luminarie from DTS, is designed for use in Zone 1, 2, 21 and 22, areas, allowing the same luminaries to be used across a hazardous area site, whether it is oil and gas or food and beverage. The XFF ATEX luminarie combines high quality with a large range of features. Tubular fluorescent fitting - Polycarbonate Manufactured from marine grade aluminum Finishing Yellow offshore All components mounted on slide out gear tray Easy access for installation and maintenance Automatic switch off upon opening for safe maintenance Standard components used inside the body allowing reduced maintenance costs Electronic ballast 220 - 240V 50/60Hz No lamp included Approvals EN60079-0, 60079-1, 60079-31 INERIS 11 ATEX 0051X Ex II 2 G Ex d IIC T6 Gb for ≤ -20°C to ≤ +55°C Ex II 2 D Ex tb IIIC T80°C Db IP66 Supplied with One 3/4 in NPT nickel-plated brass cable gland for non armoured cable (12-16 mm), one 3/4 in NPT nickel-plated brass stopping plug and two zinc plated steel articulated brackets for ceiling mounting (D023)
New items
XLF105P-00000, DTS

XLF105P-00000, DTS

Floodlight- 105W LED - wide beam - with galvanised steel flat mounting bracket - electronic converter 100-254Vac 50-60Hz - Offshore grade yellow paint RAL 1003 - includes - one nickel-plated brass M20 cable gland for non-armoured cable diameter 10-16mm and one nickel-plated brass M20 plug. XLF LED Floodlight fitting Lumen output 7 800 lm Current 0.5A @ 230Vac Suitable for use in Zones 1, 2, 21, 22
New items
EVS240, DTS

EVS240, DTS

Zone 1, 2, 21 & 22 Ex-e The EVS Series of hazardous area Ex e fluorescent luminaries from DTS, is designed for use in Zone 1, 2, 21, and 22 areas, allowing the same luminaries to be used across a hazardous area site, whether it is oil and gas or food and beverage. The EVS ATEX luminaries combine high quality with a large range of features. Fluorescent fitting with easy disconnect 5 wire or 3 wire Loop electronic ballast 220- 240V 50/60Hz Main body constructed of a GRP for high impact strength Polycarbonate diffuser to resist harsh environments Automatic switch off upon opening for safe maintenance All components mounted on hinged and removable gear tray Easy access for installation and maintenance Lamp not supplied Approvals EN60079-0, 60079-1, 60079-5, 60079-7, EN61241-1 LCIE 11 ATEX 3065X IEC Ex LCI 11,0053X Ex II 2 G Ex de IIC T4 Gb for ≤ -40°C to ≤ +60°C Ex de IIC T5 Gb for ≤ -40°C to ≤ +35°C Ex II 2 D Ex tb IIIC T85°C Db IP66 IEC 60529 (2001) IP66 Supplied with One nylon M20 cable gland (6-12mm), two M20 nylon plugs & two zinc plated steel brackets for ceiling mounting (V015)
New items
XEL30011, DTS

XEL30011, DTS

Miniature Tubular fluorescent fitting, Zone 1, 2, 21 & 22 Ex d The XEL hazardous area Ex d tubular fluorescent luminaire from DTS, is designed for use in Zone 1, 2, 21 and 22, areas, allowing the same luminaires to be used across a hazardous area site, whether it is oil and gas or food and beverage. The XEL ATEX luminaire combines high quality with a large range of features. Miniature tubular fluorescent fitting - Polycarbonate Electronic ballast 220 - 240V 50/60Hz Finishing Yellow offshore Manufactured from marine grade aluminium All components mounted on slide out gear tray Easy access for installation and maintenance Automatic switch off upon opening for safe maintenance Standard components used inside the body allowing reduced maintenance costs No lamp included Approvals EN60079-.0, 60079-1, 60079-7, 60079-31 INERIS II ATEX 0051X Ex II 2 G Ex d IIC T6 Gb Ex II 2 D Ex tb IIIC T80°C Db IP66 Supplied with One 3/4" NPT brass cable gland for non armoured cable (12-16mm), one 3/4 NPT nickel-plated brass stopping plug and two zinc plated steel articulated brackets for ceiling mounting (D023)
New items
XFFL240V-00000, DTS

XFFL240V-00000, DTS

Tubular LED fixture - Glass tube - 59W - universal electronic driver 100-254V 50-60Hz and LED module - Offshore grade yellow paint RAL 1003 - includes - one 3/4 NPT nickel plated brass cable gland for non-armoured cable diameter 6-12 mm, one nickel plated 3/4 NPT stopping plug and two zinc-plated steel articulated brackets for ceiling mounting (D023) - INERIS 13 ATEX 0050X, II 2 GD, Ex d IIB T6 Gb , Ex tb IIIC T80C Db (-20C to 55C) XFFL Tubular LED fitting 5 wires Glass Diffuser Equipped with 1 cable gland & 1 plug Suitable for use in Zones 1, 2, 21, 22