Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Products Found: 4

Showing Results For: Acoustic Analysis & Testing

Acoustic Analysis & Testing


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Rohs Verified
600 000 302, Neutrik
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 44.42
NTi Audio AG
Rohs Verified
XL2, NTi Audio AG
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 2107.06
Rohs Verified
MRPRO-POWERSUPPLY, Neutrik
2 In Stock
Check Stock & Lead Times Packaging Options
15 +
£ 24.78
1 +
£ 26.86
100 +
£ 22.03
Rohs Verified
MRPRO-CAB-TESTPLUG, Neutrik
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 42.49
15 +
£ 39.24
50 +
£ 36.42
Showing
1 -

New Items
New items
MRPRO-CAB-TESTPLUG, Neutrik

MRPRO-CAB-TESTPLUG, Neutrik

Minirator MR-PRO Audio Signal Generator Enhanced analogue audio signal generator Sine wave, sweeps, white noise, pink noise Proprietary user wave forms may be loaded via USB into the internal flash memory Continuous monitoring of the impedance of the connected load, the signal balance and the phantom power Integrated cable testing, polarity and delay Outputs Balanced XLR, unbalanced RCA, phantom power resistant Inputs DC power supply, USB, XLR for cable test Wave Forms Sine, Pink Noise, White Noise, Polarity Test Signal, Delay Test Signal Wave File Format Sampling frequency 48 kHz Resolution 16 bit, mono Output level 0 dBFS = 18 dBu (sine) according to EBU R68 Frequency Setting Range 10 Hz - 20 kHz Increment in 1 digit steps Accuracy 0.01% Stepped Sweep Function Frequency range freely selectable Increment 1//1, 1//3, 1//6, 1//12 octave Sweep speed selectable 0.5 - 5 seconds Continuous Sweep (Chirp) Function Frequency range freely selectable Increment Linear / Logarithmic Chirp speed 0.5 - 20 seconds per cycle Level Units dBu, dBV, V, dBFS, % Output Level Ranges Sine, sweep, chirp - 80 dBu to +18 dBu White noise - 80 dBu to +10 dBu Pink noise - 80 dBu to + 8 dBu polarity, delay test - 80 dBu to +16 dBu Flatness ± 0.2 dB Accuracy @ 1kHz ± 0.2 dB THD+N 22 Hz - 22 kHz, average, @ 1 kHz, typical 96 dB (0.0016 %) @ 18 dBu Noise floor Output Impedance 12.5Ω balanced Imax = 10mA Impedance Measurement Method Absolute value Z Measurement range 4 Ohm - 50 kOhm balanced 2 Ohm - 25 kOhm unbalanced @ f = 30 Hz to 10 kHz (Sine) @ Level from -20 to +18 dBu Accuracy ± 10 % or ± 2 Ohm Phantom Power Reading Measurement range 0 - 54 V Accuracy ± 3 % or ± 0.5 V USB Functionality Firmware update Mass Storage Device Flash Memory 32 MByte for storing wave files and configurations Display Graphical, with back light Auto Power Off 10, 30, 60 minutes or OFF Batteries 3 x AA Alkali...
New items
XL2, NTi Audio AG

XL2, NTi Audio AG

XL2 Acoustic Analyzer A unique combination of state of the art sound level meter, comprehensive acoustical analyzer and a powerful audio analyzer. Acoustic analyzer measures sound level, 1/3rd octave real time spectrum, FFT, RT60 reverberation time, delay, polarity, STI-PA speech intelligibility (optional) Audio analyzer function measures Level RMS, THD and frequency Flexible user interface with personalised application profiles Sound level meter meets the international standards for environmental Noise (DIN15905-5 DE / SLV 2007 CH) including the required correction values Voice Notes for logged measurements Generates 48 VDC phantom power and offers automated microphone identification Mini-SD-Card, removable Built-in real time clock Rechargeable replaceable Li-Po battery M4260 microphone must be ordered separately Sound Level Meter Product Configurations XL2 with M4260 microphone: Class 2 acc. to IEC 61672 Conforms with Standards IEC 61672, IEC 60651, IEC 60804, ANSI S1.4, ANSI S1.43, DIN 15905-5, DIN 45645-1*, DIN 45645-2, SLV 2007 Measurements SPL actual, Leq, Lmin, Lmax, LCpeak Gliding LAeq with t = 5", 10', 15' and 60' All measurement results are simultaneously available Correction value measurement wizard Logging all data or subsets in selectable intervals Recording of WAV-files (ADPCM) and voice notes Limit monitoring showing exceeding sound levels Level Resolution: 0.1 dB Internal noise: 1.3 μV A-Weighted Weighting Frequency weighting: A, C, Z Time weighting: Fast, Slow, optional: Impulse Real Time Analyzer Frequency Resolution: 1/3 octave, 1/1 octave, wide band Frequency Range: 6.3 Hz to 20 kHz Level Resolution: 0.1 dB Band pass filters conform IEC 61260 class 0, ANSI S1.11-2004, class 1 Acoustic Analyzer FFT Analysis Real time FFT with LZF and Leq Level Resolution: 0.1 dB Frequency ranges: 7 Hz - 215 Hz, 58 Hz - 1.72 kHz, 484 Hz - 20.5 kHz with 142 frequency...
New items
600 000 302, Neutrik

600 000 302, Neutrik

The Minirator MR-PRO provides a full set of analog audio signals including sine wave, pink noise, white noise, delay test signal, polarity test signal, stepped sweep and continuous sine sweep. Further, a set of wav-files, useful for system optimization, is stored in the internal flash memory. Add your own personal favourites to this set Installed Sound Life Safety Systems Live Sound Broadcast Building Acoustics Industrial and Aerospace Quality Control The Ever-ready Pouch protects the instrument during transport and operation. With its convenient belt clip, the instrument can be kept close by for those tasks requiring both hands. The Ever-ready Pouch allows operation of the instrument while fitted in the pouch. MR2 requires additional Shock Protection Jacket
New items
MRPRO-POWERSUPPLY, Neutrik

MRPRO-POWERSUPPLY, Neutrik

Minirator MR-PRO Audio Signal Generator Enhanced analogue audio signal generator Sine wave, sweeps, white noise, pink noise Proprietary user wave forms may be loaded via USB into the internal flash memory Continuous monitoring of the impedance of the connected load, the signal balance and the phantom power Integrated cable testing, polarity and delay Outputs Balanced XLR, unbalanced RCA, phantom power resistant Inputs DC power supply, USB, XLR for cable test Wave Forms Sine, Pink Noise, White Noise, Polarity Test Signal, Delay Test Signal Wave File Format Sampling frequency 48 kHz Resolution 16 bit, mono Output level 0 dBFS = 18 dBu (sine) according to EBU R68 Frequency Setting Range 10 Hz - 20 kHz Increment in 1 digit steps Accuracy 0.01% Stepped Sweep Function Frequency range freely selectable Increment 1//1, 1//3, 1//6, 1//12 octave Sweep speed selectable 0.5 - 5 seconds Continuous Sweep (Chirp) Function Frequency range freely selectable Increment Linear / Logarithmic Chirp speed 0.5 - 20 seconds per cycle Level Units dBu, dBV, V, dBFS, % Output Level Ranges Sine, sweep, chirp - 80 dBu to +18 dBu White noise - 80 dBu to +10 dBu Pink noise - 80 dBu to + 8 dBu polarity, delay test - 80 dBu to +16 dBu Flatness ± 0.2 dB Accuracy @ 1kHz ± 0.2 dB THD+N 22 Hz - 22 kHz, average, @ 1 kHz, typical 96 dB (0.0016 %) @ 18 dBu Noise floor Output Impedance 12.5Ω balanced Imax = 10mA Impedance Measurement Method Absolute value Z Measurement range 4 Ohm - 50 kOhm balanced 2 Ohm - 25 kOhm unbalanced @ f = 30 Hz to 10 kHz (Sine) @ Level from -20 to +18 dBu Accuracy ± 10 % or ± 2 Ohm Phantom Power Reading Measurement range 0 - 54 V Accuracy ± 3 % or ± 0.5 V USB Functionality Firmware update Mass Storage Device Flash Memory 32 MByte for storing wave files and configurations Display Graphical, with back light Auto Power Off 10, 30, 60 minutes or OFF Batteries 3 x AA Alkali...
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Acoustic Analysis & Testing and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Acoustic Analysis & Testing or any other product.
This depends on the Acoustic Analysis & Testing individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Acoustic Analysis & Testing and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Acoustic Analysis & Testing.
Yes. We keep updating our stock frequently and if a product like Acoustic Analysis & Testing is not in stock then we will let you know.