DIN Rail Mount Blanking Plate
Cover mounted blanks are provided with each consumer unit to fill unused ways as follows: 2 x 1 way for 8 and 12 way consumer units, and 2 x 2 way for 16 and 21 way consumer units.
If additional unused ways are required, the DIN rail mount blank 5544s must be used to complete the installation.
MK Series Enclosures & Accessories
The Sentry™ range of consumer unit enclosures from MK provides a flexible solution for residential, commercial and light industrial applications, where circuit protection is required. The modular design allows flexibility of configuration, ranging from simple MCB arrangements to more complex split loads.
Curved lines, low profile apperance and colour let the unit blend with its environment
Flush mounting available for neater installations
Opaque and downward opening lid conceals protective devices and unsightly labelling
Floating busbar systems gives maximum installation flexibility
Stacking options for larger installations
Selection Guide
Step 1
Determine the type of consumer unit configuration required. e.g Split Load, Dual
Tariff, Standard or combination of split load / dual tariff. For each Switch Disconnector or RCD to be used allow 2 modular ways.
Step 2
Determine the number of outgoing circuits required. e.g Cooker, Lighting, Ring Main
etc. For each circuit to be protected by an MCB or RCBO allow 1 modular way.
Step 3
Determine what control products are required. e.g Bell Transformer, Time Delay
Switch, contactors, timeswitches etc.
Step 4
Determine the number of spare modular ways required for future upgrades. For
each spare modular way select 1 Sentry blank module
Step 5
Now add together the total number of modular ways required.
Step 6
Choose the type and size most appropriate for
your requirements.