1SAM201910R1001
The ABB Shunt trip AA1 release manual motor starter used for remote tripping. It is attached laterally on the left side of MS116, MS132 or MS165. In accordance with IEC 60947-1, the manual motor starter is switched off by AA1 if the supply voltage of the shunt trip measured during the tripping operation remains between 70% and 110% of the rated control circuit supply voltage.
Screw terminals
Suitable for manual motor starter MS116, MS132, MO132, MS165, MO166
Under Voltage Releases
For use with NZM1and 2 range of MCCBs
Note
NZM2 Release not shown
Standards
7777
Moeller - MCCBs & Accessories
All units have variable sensitivity and 3 pole control.
The Schneider Electric trip unit TM63D, with Thermal-magnetic Trip unit technology. Used in Distribution Application. With Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic) & Without Earth-leakage protection.
Sustainable
Ambient air temperature for operation -25…70 °C
The Schneider Electric trip unit TM40G, with Thermal-magnetic Trip unit technology. Used in Generator Application. With Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic) & Without Earth-leakage protection.
Sustainable
Ambient air temperature for operation -25…70 °C
The Rockwell Automation 60 V under voltage trip release is left-side mounted and adds 18 mm to the width of the manual motor starter.
Used 50/60 Hz of frequency
S800 Series MCB Accessories
A range of accessories for use with the S800 series of Single, Double and Triple pole high performance MCB's.
Auxiliary Contacts 9mm in width, left side mounting on MCB
Shunts operate between 70-110% of rated voltage, left side mounting on MCB
DIN rail mounting
Padlock hasp prevents accidental operation of the MCB when used with a securing padlock (typical stock number
339-9381
)
Accessories for NG125 Circuit Breakers
Range of electrical accessories including trip units and contacts, as well as accessories for connection, comb busbars, tooth ends and 100 A flexible connections.
MN voltage release trip unit.
MNs (0.5 s) undervoltage trip unit.
MNx trip unit for opening BP.
MX + OF shunt trip.
Auxiliary contact O/C + O/C
Auxiliary contact O/C + SD
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Circuit Trips and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Circuit Trips or any other product.
This depends on the Circuit Trips individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Circuit Trips and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Circuit Trips.
Yes. We keep updating our stock frequently and if a product like Circuit Trips is not in stock then we will let you know.