Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Pilz Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Pilz




New Items
New items
PNOZ s10 24VDC 4 n/o 1 n/c, Pilz

PNOZ s10 24VDC 4 n/o 1 n/c, Pilz

PNOZsigma series contact extension blocks Extension modules for PNOZ sigma series safety blocks. The extension blocks provide reinforcement and increase the number of safety contacts on a base device. The contact extension block expands an existing electrical circuit. Safety is still guaranteed, even if a component fails. Removable terminals with connection via spring terminals. DIN rail mounting. Standards EN 60947-5-1, EN 60204-1 VDE 0113-1
New items
774709, Pilz

774709, Pilz

PNOZ X10, Dual Channel Introducing the PNOZ X10 range of safety relay from the well-known brand PILZ, manufacturer of many safety related monitoring products. The PNOZ X10 range is the top of its class offering you different modes of operation including, single, automatic and dual channel functions. You will find that the PNOZ X10 has many different applications that you can use that offer you versatility in the face of machine safety. Features and benefits • LED indicator statuses to support switching channel status between 1 or 2 signals & also for monitoring the supply voltage currently in the relay • Featuring 6 safety contacts (instantaneous) and 4 auxiliary contacts furthering the reliability of the machines safety output. • DIN rail mounting as standard • Single/Dual channel operation • Detection of short circuits across the contacts which can specifically detect earth faults and short circuiting. Safety features • The circuit is redundant with built in self-monitoring • Safety functions remain effective in the case of a component failure • Correct opening and closing of the safety functions is tested automatically at the end of each of the relays on/off safety cycles. • Your X10 is short circuit proof, using an electronic fuse on a DC supply provides this reliability. Applications • Emergency stop buttons • Safety gate limit switches • Reset buttons • Light barriers Technical safety parameters • EN 60947-5-1 • EN 60204-1 • VDE 0113-1
New items
PSEN me3.1/2AR, Pilz

PSEN me3.1/2AR, Pilz

PSENmech Safety Switch The PSENmech from Pilz is a mechanical safety switch with separate actuator, suitable for mounting on safety guards. The interlock switch is triggered if the guards are opened, stopping any hazardous machine movement via a Pilz evaluation device. Flexibility and speed during installation plus high plant availability Compact design Can be connected to all Pilz evaluation devices Up to four horizontal and four vertical approach directions Operating temperature -30 to +80°C Screw terminals M20 Plastic bodied design IP65 protection Approvals EC, BG, CCC, cCSAus Standards VDE 0660 T100, EN 60947-1, VDE 0660 T200, EN 60947-5-1, IEC 60947-5-1 GS-ET-19 Interlock Switch
New items
PNOZ XV2 30/24VDC 2n/o 2n/o t, Pilz

PNOZ XV2 30/24VDC 2n/o 2n/o t, Pilz

PNOZ XV2 Safety Relay, Adjustable Time Delayed The PNOZ XV2 safety relay provides a safety-related interruption of a safety circuit. It meets the requirements of EN 60947-5- 1, EN 60204-1 and VDE 0113-1. Features and Benefits Relay outputs, instantaneous 2 safety contacts (n/o), positive-guided Relay outputs, delay-on re-energised: 2 safety contacts (n/o), positive-guided with adjustable or fixed delay-on de-energisation (dependent on unit) LED for operating voltage, LED's for switching positions of all output relays and reset circuit Connection for safety limit switches, E-stops, safety gate switches and for external reset buttons Output circuit is redundant Single or two channel operation Feedback control loop for monitoring external contactors/relays Prevents machine operation in the event of a power supply failure, component failure, coil defect in a relay, cable break and earth fault DIN Rail mounted Screw terminals Applications The PNOZ XV2 safety relay is used in applications with E-stops and safety gates. Approvals CE, cULus Listed, TÜV, KOSHA, CCC. Standards EN 60204-1, EN 62061, EN ISO 13849-1, VDE 0113-1, EN 60947-5-1.
New items
PSEN cs3.1p, Pilz

PSEN cs3.1p, Pilz

PSENcode Compact Non-Contact Safety Switch, Coded The PSEN cs3.1 and PSEN cs3.1p safety switches are coded and only switch with an actuator from the PSEN cs3.1 series. There is no restriction on the number of times the actuator can be used and reset. Features and Benefits Transponder technology for presence detection (safety function) Coded switch Dual-channel operation 2 safety inputs for series connection of multiple safety switches 2 safety outputs 1 signal output LED display for state of the actuator, state of the inputs and supply voltage/fault 1 direction of actuation IP69K protection Stock no. 918-6655 has an M12 8 pole male connector Stock no. 918-6664 has an M8 8 pole male connector Approvals CE, cULus Listed, TÜV, BG, CCC. Caution The safety level PLe (Cat. 4)/SIL CL 3 is only achieved if the safety outputs use 2-channel processing. Standards EN 60947-5-3 with the actuator PSEN cs3.1 PDDB; EN 62061 SIL CL 3; EN ISO 13849-1 PLe Cat. 4; EN ISO 14119 coding level Low, Type4. Supplied with Actuator.
New items
PNOZ s6 48-240VACDC 3 n/o 1 n/c, Pilz

PNOZ s6 48-240VACDC 3 n/o 1 n/c, Pilz

PNOZ s6 and PNOZ s6.1 Safety Relays Safety relay for two-handed controls During dangerous movements, the relay requires the operator to keep both hands out of the danger zone Applications: mechanical presses, hydraulic presses, safety control circuits Removable terminals with connection via spring terminals Display LEDs for relay status DIN rail mounting 1 solid state output Standards EN574 IIIC (PNOZ s6); EN574 IIIA (PNOZ s6.1)
New items
PSEN b1, Pilz

PSEN b1, Pilz

PSENbolt The PSENbolt from Pilz comprises of a handle and bolt to provide protection against failure and manipulation in areas where safety gates are frequently opened and closed, or difficult to adjust. Ready made solution comprising bolt and handle Space saving due to compact design Mechanical protection of the safety switch ensures long service life Protection from manipulation and defeat in conjunction with the coded safety switch PSENcode Suitable for use on left and right hand gates Slot on bolt to allow a padlock to be fitted to to stop it being opened or closed unintentionally Note The PSEN b1 is without escape release and without locking pin. The PSEN b2 is with escape release and has a locking pin (which can be deactivated) to protect the bolt from closing unintentionally.
New items
PSEN rs pulley flex, Pilz

PSEN rs pulley flex, Pilz

PSEN Safety Rope Pull Accessories A range of accessories to support the Pilz PSENrope safety rope pull switch.
New items
632025, Pilz

632025, Pilz

"Infrared protected field is generated LED indicator for status information Optical synchronisation of transmitters and receivers Aluminium alloy housing Die-cast zinc end caps Shock resistance "
New items
PNOZ s6.1 24VDC 3 n/o 1 n/c, Pilz

PNOZ s6.1 24VDC 3 n/o 1 n/c, Pilz

PNOZ s6 and PNOZ s6.1 Safety Relays Safety relay for two-handed controls During dangerous movements, the relay requires the operator to keep both hands out of the danger zone Applications: mechanical presses, hydraulic presses, safety control circuits Removable terminals with connection via spring terminals Display LEDs for relay status DIN rail mounting 1 solid state output Standards EN574 IIIC (PNOZ s6); EN574 IIIA (PNOZ s6.1)
New items
750106, Pilz

750106, Pilz

PNOZ s6 and PNOZ s6.1 Safety Relays Safety relay for two-handed controls During dangerous movements, the relay requires the operator to keep both hands out of the danger zone Applications: mechanical presses, hydraulic presses, safety control circuits Removable terminals with connection via spring terminals Display LEDs for relay status DIN rail mounting 1 solid state output Standards EN574 IIIC (PNOZ s6); EN574 IIIA (PNOZ s6.1)
New items
542000, Pilz

542000, Pilz

PSENcode Slim Non-Contact Safety Switch, Coded The PSEN cs5.11 and PSEN cs5.1p safety switches are coded and only switch when used with an actuator from the PSEN cs1.1 series. There is no restriction on the number of times the actuator can be used and reset. Features and Benefits Transponder technology for presence detection Coded switch Dual-channel operation 2 safety inputs for series connection of multiple safety switches 2 safety outputs Safety Device Diagnostics (SDD) Safety Device Diagnostics can be used to poll sensor information, to perform actions and to read configuration parameters Diagnostic input for Y1 for Safety Device Diagnostics (SDD) Signal output/diagnostic output Y32 for Safety Device Diagnostics LED display for state of actuator detection, state of the inputs and supply voltage/fault IP66 / IP67 protection PSEN cs5.11 (stock no. 918-6667 ) 1 actuation direction with 3 approach directions: square marking for normal operating distance M12 8 pole male connector 30 N holding force PSEN cs5.1p (stock no. 918-6661 ) 4 actuation directions, each with 3 approach directions: square marking for normal operating distance and triangle marking for short operating distance M8 8 pole male connector Caution The safety level PLe (Cat. 4)/SIL CL 3 is only achieved if the safety outputs use 2-channel processing. Standards EN 60947-5-3; EN 62061 SIL CL 3; EN ISO 13849-1 PLe Cat. 4; EN ISO 14119 Coding level Low, Type4. Approvals CE, TÜV, UL/cUL, FCC, IC, ECOLAB. Supplied with Actuator.