New Items
New items
APM110E, Unipower

APM110E, Unipower

APM110E - Analogue Motor Load Monitor The APM110E is a monitor- and protection unit for motors. The unit measures kW used by a 3-phase motor to detect machine overload or under load. Commonly used to protect pumps, conveyors, macerators, scrapers and filtration screens. Features output connections for the PCU D10, remote front panel display and control module. Supply voltage from 1x 120/230 Vac Voltage range from 3x 230-575 Vac Programmable max. and min. kW limit detector plus the support functions Internal current transformer for currents up to 80A Power range max. 80 kW with internal current sensor Auto and manual reset DIN rail mounting An external display (PCU D10; Stock-no.: 793-4111 ) can be connect via 2-wire connection Unipower Motor Protection
New items
APM10, Unipower

APM10, Unipower

APM10 - kW-Transmitter The APM10 is a monitor- and protection unit for motors. The unit converts kW into an analogue process signal for use in PLC's and other controllers. Transmitter for kW, 3 phase symmetrical load For connecting to a 3 phase net of up to 3x500 Vac Internal Current Transformer Input Current Range 5, 10, 20, 25, 40, 60 Aac 24 V Power Supply Analogue output 0(4)-20mA or 0(2)-10V DIP switch settings for output signal Galvanic insulation between input and output Test Voltage 3 kV Unipower Motor Protection
New items
HPL500, Unipower

HPL500, Unipower

HPL500 Digital Motor Load Monitor The HPL500 replaces the HPL420 and also incorporates many new features, however it has been designed so that users of the HPL420 will be familiar with its set-up procedure. The display is used as a reference enabling true motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons. For two speed motor applications an input allows the application to select the active limit The HPL500 is usually mounted in the motor control panel and is connected to a convenient point on the motor supply (before Inverter - if used). Therefore no external field wiring or sensors in the equipment are necessary. In addition to displaying true motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up trip limits and fault diagnosis. The HPL500 features a current feed-through tube for measuring continuous motor currents up to 40 amps, (27.7kW at 3 x 400vac). Therefore no Current Transformer is required unless the motors continuous current exceeds 40A. A specially designed power supply (Patent Pending) allows the motor voltage to be programmable from 100 – 400vac single phase and 100 – 575vac 3-phase making the HPL500 suitable for world-wide use. The 0(4)-20ma analogue output, which is proportional to motor load, can be scaled to the range of measured power and can be inverted for use in closed loop control systems. Measures true motor load in kW (√3 x I x V x Cosφ) and futures a digital display of kW% and kW, and programmable trips for over and/or under load events Can be programmed to calculate Shaft Output Power P2 if required Protects equipment from damage caused by the motor running against a jam, blockage or under load Used in processes to trigger actions when predetermined load levels are reached (end point monitoring) Three digital d...
New items
HPL110A, Unipower

HPL110A, Unipower

Digital Motor Load (kW) Monitors Units which measure true motor load in kW featuring a digital display of kW% and programmable trips for over and/or under load events.These units protect equipment from damage caused by the motor running against a jam, blockage or under load and are also used in processes to trigger subsequent actions when predetermined load levels are reached (end point monitoring).The display is used as a reference enabling motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons.The units are usually mounted in the motor control panel and are connected to a convenient point on the motor supply (before Inverter - if used).Therefore no external field wiring or sensors in the equipment are necessary. In addition to displaying motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up and fault diagnosis.Three digital delay timers, programmable from 0.1-25 seconds are incorporated to time out motor start surge and short duration over and under power events which could cause nuisance tripping.A DIP switch is used to tamper proof all settings. The HPL110 and HPL110A can be switched to either 50 or 6necessary.In0Hz operation.Both units can be operated in manual or auto-reset modes. In auto-reset mode programmable hysteresis, which provides differential between trip and reset levels is automatically enabled.The HPL 110 is DIN rail mounting whilst the HPL110A can be panel mounted.Applications include the over/underload protection of:Pumps (dry run, closed valve), Fans (broken belt, closed damper), Conveyors (screw and belt),Separation screens, Macerators, scrapers, Mechanical drives (gearboxes, chains)
New items
HPL110, Unipower

HPL110, Unipower

Digital Motor Load (kW) Monitors Units which measure true motor load in kW featuring a digital display of kW% and programmable trips for over and/or under load events.These units protect equipment from damage caused by the motor running against a jam, blockage or under load and are also used in processes to trigger subsequent actions when predetermined load levels are reached (end point monitoring).The display is used as a reference enabling motor load, trip levels and all other variables to be displayed and programmed quickly and accurately using only three push buttons.The units are usually mounted in the motor control panel and are connected to a convenient point on the motor supply (before Inverter - if used).Therefore no external field wiring or sensors in the equipment are necessary. In addition to displaying motor power in real time the units capture and, on demand, display the instantaneous minimum and maximum power levels to assist in setting up and fault diagnosis.Three digital delay timers, programmable from 0.1-25 seconds are incorporated to time out motor start surge and short duration over and under power events which could cause nuisance tripping.A DIP switch is used to tamper proof all settings. The HPL110 and HPL110A can be switched to either 50 or 6necessary.In0Hz operation.Both units can be operated in manual or auto-reset modes. In auto-reset mode programmable hysteresis, which provides differential between trip and reset levels is automatically enabled.The HPL 110 is DIN rail mounting whilst the HPL110A can be panel mounted.Applications include the over/underload protection of:Pumps (dry run, closed valve), Fans (broken belt, closed damper), Conveyors (screw and belt),Separation screens, Macerators, scrapers, Mechanical drives (gearboxes, chains) Sorry Your request could not be completed at this time
New items
DSU D382, Unipower

DSU D382, Unipower

DSU D382 - Front Panel Display/Control Unit for APM382 DSU d382 is a display/programming unit for the universal measuring/control unit APM382. The DSU has no measuring circuit and cannot be used without the APM382. The DSU d382 is meant as a supplement for the APM382 if it is required to have the power measurements and the control status displayed or if programming of the APM382 needs to be done from the front of the control panel without the otherwise necessary connection to a PC. Supply voltage 15-30 Vdc Setting up the d382 (APM382) is done using three keys on the front 16 LEDs for indicate the unit RS232C link IP54 protection Panelmounting Cut out 68x68 mm For use with the APM382 load monitor (Stock-no.: 793-4115 ) Unipower Motor Protection
New items
APM382, Unipower

APM382, Unipower

APM382 - Analogue Load Monitor The APM382 is a combined electronic power measurement transducer and load monitor that measures power in kW on 3-phased asymmetric loads, including frequency inverter. Measures after frequency inverters; PWM 10Hz - 1kHz 10 current measuring ranges up to 80A internally Digital scaling of the selected range (Zoom) Programmable filter function (analogue and digital) 2 independent alarm limits plus dP/dt (shock load) alarm Alarm inhibit inputs and external reset input 0(4)-20mA and 0(2)-10V analogue outputs Galvanic isolation between mains net and I/O Setup of parameters via PC with software 382Mon Optocoupled alarm outputs An external display (DCU D382; Stock-no.: 793-4124 ) can be connect Unipower Motor Protection