Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Celduc Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Celduc


Categories For Celduc




New Items
New items
SO945460, Celduc

SO945460, Celduc

Single-phase solid state relays, SO9 series Synchronous solid state relay suited to most loads. TMS 2 technology thyristor output ensures longevity. Voltage protection for input as well as output (VDR) for very high immunity to interference. Wide control range: 20 → 265 Vac / dc with regulated control current. Green LED input display. Solid state relays must be mounted on a heatsink. ref. Celduc Switching current Switching voltage Control voltage SO941460 12 A 12 → 280 Vac 3 → 32 Vdc SO942460 25 A 12 → 280 Vac 3 → 32 Vdc SO943460 35 A 12 → 280 Vac 3 → 32 Vdc SO945460 50 A 12 → 280 Vac 3 → 32 Vdc SO963460 35 A 24 → 600 Vac 3.5 → 32 Vdc SO965460 50 A 24 → 600 Vac 3.5 → 32 Vdc SO967460 75 A 24 → 600 Vac 3.5 → 32 Vdc Input characteristics Non-operating voltage: 5 V Control current: 5 → 10 mA Output characteristics Dynamic resistance: 12 m Ω Input / output isolation voltage: 4000 Vrms Closing time: 30 ms Opening time: 30 ms Operating frequency: 0.1 → 800 Hz Operating temperature: -40 °C → +80 °C Dimensions (mm): 58 x 29 x 45 WF070000 Rth j / c = 0.75 k / w 0.75 k / W Dimensions (mm): 110 x 100 x 100 Weight (kg): 1.42 WF050000 Rth j / c: 0.55 k / W Dimensions (mm): 110 x 200 x 100 Weight (kg) 2.84 Standards EN60947-4-3 and EN60950 Instantaneous Switching Note Temperature can affect current rating; please consult the data sheet for potential derating.
New items
SO865970, Celduc

SO865970, Celduc

Single-phase solid state relays, SO8 series Synchronous solid state relay suited to most loads. Voltage protection for input (transil) as well as output (VDR) for high immunity to interference. Wide control range: 3 → 32 Vdc with regulated control current. Green LED input display. Solid state relays must be mounted on a heatsink. ref. Celduc Switching current Switching voltage Control voltage SO842074 25 A 12 → 275 Vac 3 → 32 Vdc SO842974 25 A 12 → 275 Vac 20 → 265 Vac / dc SO843070 35 A 12 → 275 Vac 3 → 32 Vdc SO843970 35 A 12 → 275 Vac 20 → 265 Vac / dc SO845070 50 A 12 → 275 Vac 3 → 32 Vdc SO847070 75 A 12 → 275 Vac 3 → 32 Vdc SO848070 95 A 12 → 275 Vac 3 → 32 Vdc SO849070 125 A 12 → 275 Vac 3 → 32 Vdc SO863070 35 A 24 → 510 Vac 3.5 → 32 Vdc SO863970 35 A 24 → 510 Vac 20 → 265 Vac / dc SO865070 50 A 24 → 510 Vac 3.5 → 32 Vdc SO865970 50 A 24 → 510 Vac 20 → 265 Vac / dc SO867070 75 A 24 → 510 Vac 3.5 → 32 Vdc SO867970 75 A 24 → 510 Vac 20 → 265 Vac / dc SO868070 95 A 24 → 510 Vac 3.5 → 32 Vdc SO868970 95 A 24 → 510 Vac 20 → 265 Vac / dc SO869070 125 A 24 → 510 Vac 3.5 → 32 Vdc SO869970 125 A 24 → 510 Vac 20 → 265 Vac / dc Input characteristics Non-operating voltage: 2 V Control current: Output characteristics dynamic resistance; 3.5 m Ω Input / output isolation voltage: 4000 Vrms Closing time: 10 ms Opening time: 10 ms Operating frequency: 0.1 → 800 Hz Operating temperature: -40 °C→ +85 °C Dimensions (mm): 58 x 30 x 45 WF070000 Rth j / c = 0.75 k / w 0.75 k / W Dimensions (mm): 110 x 100 x 100 Weight (kg): 1.42 WF050000 Rth j / c: 0.55 m k / W Dimensions (mm): 110 x 200 x 100 Weight (kg) 2.84 Standards EN60947-4-3 and EN60950 Instantaneous Switching Note Temperature can affect current rating; please consult the data sheet for potential derating.
New items
SO845970, Celduc

SO845970, Celduc

Single-phase solid state relays, SO8 series Synchronous solid state relay suited to most loads. Voltage protection for input (transil) as well as output (VDR) for high immunity to interference. Wide control range: 3 → 32 Vdc with regulated control current. Green LED input display. Solid state relays must be mounted on a heatsink. ref. Celduc Switching current Switching voltage Control voltage SO842074 25 A 12 → 275 Vac 3 → 32 Vdc SO842974 25 A 12 → 275 Vac 20 → 265 Vac / dc SO843070 35 A 12 → 275 Vac 3 → 32 Vdc SO843970 35 A 12 → 275 Vac 20 → 265 Vac / dc SO845070 50 A 12 → 275 Vac 3 → 32 Vdc SO847070 75 A 12 → 275 Vac 3 → 32 Vdc SO848070 95 A 12 → 275 Vac 3 → 32 Vdc SO849070 125 A 12 → 275 Vac 3 → 32 Vdc SO863070 35 A 24 → 510 Vac 3.5 → 32 Vdc SO863970 35 A 24 → 510 Vac 20 → 265 Vac / dc SO865070 50 A 24 → 510 Vac 3.5 → 32 Vdc SO865970 50 A 24 → 510 Vac 20 → 265 Vac / dc SO867070 75 A 24 → 510 Vac 3.5 → 32 Vdc SO867970 75 A 24 → 510 Vac 20 → 265 Vac / dc SO868070 95 A 24 → 510 Vac 3.5 → 32 Vdc SO868970 95 A 24 → 510 Vac 20 → 265 Vac / dc SO869070 125 A 24 → 510 Vac 3.5 → 32 Vdc SO869970 125 A 24 → 510 Vac 20 → 265 Vac / dc Input characteristics Non-operating voltage: 2 V Control current: Output characteristics dynamic resistance; 3.5 m Ω Input / output isolation voltage: 4000 Vrms Closing time: 10 ms Opening time: 10 ms Operating frequency: 0.1 → 800 Hz Operating temperature: -40 °C→ +85 °C Dimensions (mm): 58 x 30 x 45 WF070000 Rth j / c = 0.75 k / w 0.75 k / W Dimensions (mm): 110 x 100 x 100 Weight (kg): 1.42 WF050000 Rth j / c: 0.55 m k / W Dimensions (mm): 110 x 200 x 100 Weight (kg) 2.84 Standards EN60947-4-3 and EN60950 Instantaneous Switching Note Temperature can affect current rating; please consult the data sheet for potential derating.
New items
P3150000, Celduc

P3150000, Celduc

Magnetically-controlled proximity sensors PL / PAA series magnetically-controlled proximity sensors (rectangular housing). Reed switch integrated into an insulated housing. Moulded magnets. Max. operating temperature:  –40 °C → +125 °C Stock control switching switching housing no. current current current of contact 179-2873 250 Vdc 12 VA 0.4 A 1 N/O 307-6202 (100 Vdc) 3 VA 0.25 A 1 C/O 307-6218 (100 Vdc) 10 VA 0.5 A 1 N/O
New items
PTI70020, Celduc

PTI70020, Celduc

PTI series magnetic sensor Magnetic proximity sensor with Reed switch and M8 thermoplastic housing. 2-metre output cable. Detection distance up to 19 mm. LED displays operating status. Supply voltage: 5 → 100 Vdc / Vac Switched current: 0.3 A Output: N / O Protection index: IP 67 Switching frequency: 100 Hz Dimensions (mm): M8 x 33
New items
PDLA2030, Celduc

PDLA2030, Celduc

Celduc PTA/PDC Magnetic Sensors Celduc PTA/PDC series M10 magnetic proximity sensors are an extremely small package size. Featuring a normally open contact in a stainless steel housing. The PTA/PDC series comes pre cabled with a 2 wire 2 m length cable. Celduc Range
New items
SKA21441, Celduc

SKA21441, Celduc

PCB-mount vertical solid state relays These relays feature a high level of immunity to outside interference, a very low off-state leakage current and a surge suppressor. Stock no. 231-0933 425-4734 231-0949 Input characteristics (at 20 °C): Control voltage: 4 → 30 Vdc 4 → 30 Vdc 3 → 30 Vdc Release voltage: 0.8 Vdc 0.8 Vdc 1 Vdc Operating current: 3 mA 3 mA 1 mA Max. operating current: 30mA 30mA 30mA Input impedance: 1000 Ω 1000 Ω 1000 Ω Output characteristics (at 20 °C): Operating range: 12 → 275 Vac 12 → 460 Vac 2 → 60 Vdc Nominal current: 4 A 4 A 3 A Holding current: 50mA 100mA - Min. charging current: 5 mA RMS 5 mA RMS 5 mA RMS Time to closure: 10 ms 10 ms 0.2 ms Time to opening: 10 ms 10 ms 0.8 ms Operating frequency: 10 → 440 Hz 10 → 440 Hz 0 → 500 Hz Operating temperature: –40 °C → +80 °C –40 °C → +80 °C –40 °C → +90 °C
New items
XKRD30506, Celduc

XKRD30506, Celduc

Non-pull-out vertical relays for DIN rail Non-pull-out vertical relays for DIN Rail Relays for controlling all types of loads. These relays feature a high level of immunity to outside interference, a low off-state leakage current and a surge suppressor. Stock control operating control L (mm) no. voltage range nominal housing module 231-0955 6 → 30 VDC 12 → 275 Vac 4 A synchronous 11.5 334-0272 15 → 30 VAC / DC 12 → 275 Vac 4 A synchronous 11.5 334-0288 15 → 30 VAC / DC 12 → 440 VAC 4 A synchronous 16.5 334-0294 150 → 240 VAC /DC 12 → 440 VAC 4 A synchronous 16.5 231-0977 5 → 30 Vdc 2 → 60 Vdc 3 A continuous 11.5 334-0301 15 → 30 VAC / DC 2 → 60 Vdc 3 A continuous 11.5 334-0317 90 → 240 VAC /DC 2 → 60 Vdc 3 A continuous 16.5 334-0323 5 → 30 Vdc 2 → 200 VDC 1 A continuous 11.5
New items
SON865040, Celduc

SON865040, Celduc

The Celduc Zero Cross Solid State Relay designed fore most type of loads. Thyristor on output with TMS² technology for a long lifetime . Low conducted emission noise for residential application(EN 50081-1). Over-voltage protection by Thyristor turn on. Large control range with input current limiter. Green LED visualization on the input. Over-voltage protection on input (transil) Designed in conformity with EN60947-4-3 (IEC947-4-3) and EN60950 (Reinforced Insulation)IP20 protection by flaps on terminals.
New items
SKB10420, Celduc

SKB10420, Celduc

PCB-mount vertical solid state relays These relays feature a high level of immunity to outside interference, a very low off-state leakage current and a surge suppressor. Stock no. 231-0933 425-4734 231-0949 Input characteristics (at 20 °C): Control voltage: 4 → 30 Vdc 4 → 30 Vdc 3 → 30 Vdc Release voltage: 0.8 Vdc 0.8 Vdc 1 Vdc Operating current: 3 mA 3 mA 1 mA Max. operating current: 30mA 30mA 30mA Input impedance: 1000 Ω 1000 Ω 1000 Ω Output characteristics (at 20 °C): Operating range: 12 → 275 Vac 12 → 460 Vac 2 → 60 Vdc Nominal current: 4 A 4 A 3 A Holding current: 50mA 100mA - Min. charging current: 5 mA RMS 5 mA RMS 5 mA RMS Time to closure: 10 ms 10 ms 0.2 ms Time to opening: 10 ms 10 ms 0.8 ms Operating frequency: 10 → 440 Hz 10 → 440 Hz 0 → 500 Hz Operating temperature: –40 °C → +80 °C –40 °C → +80 °C –40 °C → +90 °C
New items
SOD845180, Celduc

SOD845180, Celduc

Solid state relay with diagnostic output Solid state power relay with charge, network and relay output diagnostics. TMS 2 technology thyristor output ensures longevity. Input 7 → 30 Vdc with green LED control indicator. N/C static state contact Very low synchronism level. Spring-technology pull-out input connectors. Solid state relays must be mounted on a heatsink. ref. Celduc Switching current Switching voltage Control voltage SOD845180 50 A 50 → 265 Vac 7 → 30 Vac SOD865180 50 A 150 → 510 Vac 7 → 30 Vac Input characteristics Non-operating voltage: 3 V Control current: 9 → 21 mA Output characteristics Dynamic resistance: 12 mΩ Input / output isolation voltage: 4000 Vrms Closing time: 10 ms Opening time: 10 ms Operating frequency: 0.1 → 400 Hz Dimensions (mm): 58 x 29 x 45 WF070000 RthJC = 0.75 k / W Dimensions (mm): 110 x 100 x 100 Weight (kg): 1.2 WF050000 RthJC = 0.55 k / W Dimensions (mm): 110 x 200 x 100 Weight (kg): 2.84 Standards   EN60947-4-3 Instantaneous Switching Note Temperature can affect current rating; please consult the data sheet for potential derating.
New items
SGT8879200, Celduc

SGT8879200, Celduc

The Celduc Zero Cross Solid State Relay specially designed for most types of loads. Over voltage protection on output(VDR).Back to back Thyristor on output with TMS² technology for a long lifetime expectancy, RoHS void free process. Direct copper bonding (DCB) technology Control range: 12-30VDC Green LED visualization of the inputs 90-280 VAC/DC Designed in conformity with IEC/ EN60947-4-2 and IEC/ EN60947-4-2 Built in IP20 protection with flaps