Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Products Found: 994

Showing Results For: RCCBs

RCCBs

RCCBs (Residual-Current Circuit Breakers) are electrical safety devices often integrated into circuit breaker panels or distribution boards. These protective devices are designed to protect electrical circuits against overloads, current leakage, or tripping caused by indirect contact. An RCCB safeguards individuals and valuable equipment from electrical shocks, fires, or electrocution and serves as the main disconnecting switch. Additionally, RCCBs are essential components in modern electrical installations, especially in areas with a risk of electric shocks, like homes, commercial buildings, and industrial facilities. 

Operating Principle of RCCBs:

RCCBs work by constantly monitoring the current flowing through a circuit. In case of an imbalance between the current flowing and returning from the circuit, an RCCB indicates a current leakage to the ground. In such cases, the RCCB quickly detects the imbalance and trips the circuit, cutting off the power supply and preventing potential harm to people and equipment.

Potential Benefits of RCCBs:

Using residual circuit breakers provides unmatchable benefits, such as:

  • They are easy to install and versatile. 
  • Safe performance, guaranteed with global brand certification.
  • Reduce electrical hazards by timely detecting faults.
  • Ensure personal safety, prevent fire, protect equipment, and reduce liability.
  • Offer easy integration into DIN rails with slider actuators.
  • Space saving with compact designs for residual and line current protection.
  • Come as a complete range of products with accessories.
  • Many package options are available with robust overload and shock protection.

RCCBs Types and Selection Parameters:

Generally, residual current circuit breakers are distinguished based on their trip sensitivity, current ratings, and tripping features. These devices come with 2, 3, or 4 poles as DIN rail mounted, while some common RCCB types include:

  • Type A RCCBs – These circuit breakers provide higher protection and can detect both AC and pulsating DC imbalances. They are suitable for environments where electronic devices and equipment with rectifiers are used.
  • Type B RCCBs – These RCCBs are the most advanced and sensitive type that can detect all kinds of residual currents, including pure DC. Type B RCCBs are used in medical facilities, laboratories, and industries where direct current is widely used.
  • Type AC RCCBs – These RCCB types are designed to detect alternating current (AC) imbalances and protect against common electrical faults, such as touching live wires or equipment. However, bespoke circuit breakers are not as effective at detecting direct current defects.

MCBs and RCCBs: Understanding the Key Difference

MCBs, miniature circuit breakers, and RCCBs are circuit protection devices with prominent but contrasting functions. MCBs are designed to protect against overcurrent and short circuits, whereas RCCBs protect against electric shocks and earth leakages only. However, their combined operations are ideal for robust and effective protection purposes.

Typical Applications of RCCBs: 

RCCBs are widely used in areas where electrical devices are consistently on the run. They are indispensable safety tools in various industrial, commercial, and residential facilities with multiple applications, such as:

  • Construction Sites
  • Medical Facilities
  • Data Centers
  • Agricultural Settings
  • Outdoor Power Outlets
  • Automotive and Food Processing Industry
  • Marine Applications
  • Residential Wiring, and more.

FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Legrand
Rohs Verified
411644, Legrand
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 203.78
Legrand
Rohs Verified
411651, Legrand
63 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 224.48
Legrand
Rohs Verified
411650, Legrand
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 184.22
Rohs Verified
5SV3324-3KK60, Siemens
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 548.50
Rohs Verified
5SV3346-6KK60, Siemens
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 680.97
Rohs Verified
5SV3324-6KK60, Siemens
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 477.42
Rohs Verified
5SV3344-3KK60, Siemens
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 656.76
Rohs Verified
5SV3342-6KK60, Siemens
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 450.76
Rohs Verified
5SV3322-3KK60, Siemens
31 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 541.51
Rohs Verified
5SV3346-3KK60, Siemens
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 888.60
Rohs Verified
5SV3322-6KK60, Siemens
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 429.75
Rohs Verified
5SV3342-3KK60, Siemens
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 617.18
Rohs Verified
5SV3344-6KK60, Siemens
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 493.58
Legrand
Rohs Verified
408126, Legrand
9 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 194.13
Legrand
Rohs Verified
401010, Legrand
5 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 274.52
Legrand
Rohs Verified
410499, Legrand
14 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 338.14
Legrand
Rohs Verified
401005, Legrand
104 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 632.64
Legrand
Rohs Verified
077532, Legrand
65 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 197.92
Legrand
Rohs Verified
021404, Legrand
56 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 135.52
Legrand
Rohs Verified
090476, Legrand
79 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 270.97
Schneider Electric
Rohs Verified
M9R81263, Schneider Electric
78 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 262.58
Schneider Electric
Rohs Verified
19012, Schneider Electric
7 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 354.92
Schneider Electric
Rohs Verified
19013, Schneider Electric
8 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 403.52
Schneider Electric
Rohs Verified
19034, Schneider Electric
9 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 745.62
Schneider Electric
Rohs Verified
19044, Schneider Electric
12 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 1095.57
Showing
1 -

New Items
New items
A9V12225, Schneider Electric

A9V12225, Schneider Electric

Acti9 Vigi iC60 Add on RCDs Combined with iC60 circuit breaker, the Vigi iC60 add on RCDs provide protection of persons against electric shock by direct and indirect contact and provide protection of installations against the risk of fire. The Asi type provides increased immunity from electrical interference and polluted or corrosive environments.
New items
408126, Legrand

408126, Legrand

The Legrand thermal-magnetic circuit breaker with positive contact indication for control, protection against short-circuits and overloads, and isolation of electrical circuits. Simultaneous control of all poles for closing and opening
New items
2CCL562330E1324 FS401MK-C32/0.3, ABB

2CCL562330E1324 FS401MK-C32/0.3, ABB

The ABB has pluggable residual current operated circuit breaker with 2 poles and over-current protection, for the SMISSLINE TP System. The rated breaking capacity Icn is 10 kA and rated current is 32 A. The tripping characteristic of the circuit breaker i IP20 degree of protection and rated sensitivity ( Δn) is 0.3 Operating temperature range is from -25°C to 40°C
New items
5SV3311-6, Siemens

5SV3311-6, Siemens

Series 5SV3 RCCBs Professional range of Siemens RCCB's from the 5SV3 series. Available in 2 or 4 pole verisions. Each breaker can be DIN Rail mounted. All models are highly reliable and excellent quality. Residual Current operated circuit breaker for Personnel and fire protection Silicone Free 2 or 4 pole Instant tripping, surge current withstand capability >1kA DIN rail mounting Equipment life span: >10 000 Switching cycles Enclosure: IP20 Ambient temperature: -25→+45 °C Break Time - Instantaneous Safe Protection against Residual Currents New Type for More Convenience Easy and Safe Installation Siemens RCDs, RCBOs, RCCBs and MCBs Type B characteristic offers instantaneous short circuit response level of 3-5 x normal rated current, making it suitable for circuits with moderate inrush currents such as filament lamps, heating loads and most domestic/small building protection applications.,Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used. Type D characteristic is designed for high inrush loads. Magnetic trip point - 10 to 20 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. Type AC characteristic ensure tripping for sinusoidal, alternating currents, whether they be quickly applied or slowly to increase.
New items
235390 PFIM-25/2/003-MW, Eaton

235390 PFIM-25/2/003-MW, Eaton

RCDs Manufactured to BS EN 61008 30 and 100mA trip options 2 and 4 pole options (@30mA)
New items
2CSF204101R1800 F204 A-80/0,03, ABB

2CSF204101R1800 F204 A-80/0,03, ABB

The ABB F200 series residual current circuit breaker assures protection to people and installations against fault current to earth. It detects pulsating current with DC component. It is mainly used for general applications such as industrial, household and commercial. Degree of protection IP2X Operating temperature range of -25 to +55 °C Optimum frequency range of 50 to 60 Hz DIN rail mounting
New items
236726 PXF-16/2/001-A, Eaton

236726 PXF-16/2/001-A, Eaton

Eaton Residual Current Circuit Breakers (RCCBs) - PXF-A Series Features & Benefits What type of RCD do I need? Fixed RCDs Socket-Outlet RCD Portable RCD plugs
New items
236775 PXF-25/4/05-A, Eaton

236775 PXF-25/4/05-A, Eaton

Eaton Residual Current Circuit Breakers (RCCBs) - PXF-A Series Features & Benefits What type of RCD do I need? Fixed RCDs Socket-Outlet RCD Portable RCD plugs
New items
236778 PXF-40/4/03-A, Eaton

236778 PXF-40/4/03-A, Eaton

Eaton Residual Current Circuit Breakers (RCCBs) - PXF-A Series Features & Benefits What type of RCD do I need? Fixed RCDs Socket-Outlet RCD Portable RCD plugs
New items
167893 FRCDM-40/4/003-G/B, Eaton

167893 FRCDM-40/4/003-G/B, Eaton

Eaton Residual Current Circuit Breakers (RCDs) - FRCdM Series Types B, B+ and Bfq Features and Benefits What type of RCD do I need? Fixed RCDs Socket-Outlet RCDs Portable RCD plugs
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like RCCBs and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding RCCBs or any other product.
This depends on the RCCBs individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for RCCBs and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including RCCBs.
Yes. We keep updating our stock frequently and if a product like RCCBs is not in stock then we will let you know.