ESP 690/12.5/WT, WJ Furse

ESP 690/12.5/WT, WJ Furse

Wind turbine main distribution board Enhanced surge protector Enhanced surge protector for use on main distribution board in wind turbines Low let-through voltage to BS EN 62305 Varistor design eliminates follow current Status indication Use three units for TNC systems and four units for TNS systems ESP 690/25/WT ESP 690/12.5/WT Max. Surge Current 40 kA 20 kA Max. Voltage Rating 750 V 750 V Mounting Type Top hat DIN rail Top hat DIN rail Operating Temp. Range -40 to +80°C -40 to +80°C Dimensions 90 x 72 x 68 mm 90 x 54 x88 mm Transient Voltage Suppressors (Wind Turbines)
New items
ESP 240 D1, WJ Furse

ESP 240 D1, WJ Furse

WJ Furse Power distribution systems enhanced surge protector- ESP-D1 Series Enhanced surge protector for use on power distribution systems Very low let-through voltage between all lines (L-E, L-N, N-E) LED status indication with pre-failure warning Remote indication through volt-free contact Robust steel housing Compact DIN housing Neutral to Earth voltage warning ESP 240 D1 ESP 415 D1 Max. Surge Current 40 kA 40 kA Max. Voltage Rating 280 V 280 V Mounting Type Top hat DIN rail Top hat DIN rail Operating Temp. Range -40 to +80°C -40 to +80°C Dimensions 90 x 72 x 88 mm 90 x 144 x88 mm Surge Protection Devices, SPDs (DIN-rail) Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.
New items
CR105, WJ Furse

CR105, WJ Furse

Furse Rod to Tape Clamp (type A) Furse Rod to Tape Clamp (Type A) is designed to connect earth rod to copper tape to complete earth rod assembly. Conductivity and mechanical strength are essential considerations in clamp design to ensure that an earthing system remains operative for many years. Features Corrosion resistance High-quality copper and aluminium alloys Phosphor bronze fitting Tightening torque 15 Nm Applications Used to connect earth rod to copper tape. Standards IEC/BS EN 62561-1 Class H BS 7430 UL467 Designed for connection of flat tape conductor to an earth rod. Corrosion resistance, conductivity and mechanical strength are essential considerations in clamp design to ensure an earthing system remains operative for many years. All Furse earth rod clamps have high strength copper alloy bodies and screws e.g. aluminium bronze, phosphor bronze etc., commercial brass is not used Tightening torque 15 Nm UL467 (CR105)
New items
ESP 15E, WJ Furse

ESP 15E, WJ Furse

Single 1.25A twisted-pair lightning surge arrestors - ESP E Series Low-resistance enhanced surge protector suitable for twisted pair signalling applications. Low let-through voltage between all lines Very low (1Ω) in-line resistance High (1.25A) maximum running current Wide bandwidth Sturdy, flame retardant, ABS housing Removable DIN rail foot for easy installation. Product can also be flat-mounted Colour coded terminals M6 earth stud Accessories Combined Mounting & Earth Kit: CME 4 ( 239-731 ) Weatherproof enclosures available: WBX3 230x80x85mm ( 456-8112 ); WBX4 235x160x117mm ( 456-8106 ) ESP 06E ESP 15E ESP 30E ESP 50E ESP 110E Max. Working Voltage Rating 7.79 V 19V 37.1V 58V 132V Current rating (Signal) 1.25A 1.25A 1.25A 1.25A 1.25A Max Surge Current 8/20μs to ITU-T K.45:2003,IEEE C62.41.2:2002 - Per signal wire 10kA 10kA 10kA 10kA 10kA Max Surge Current 8/20μs to ITU-T K.45:2003,IEEE C62.41.2:2002 - Per pair 20kA 20kA 20kA 20kA 20kA Operating Temperature -40 to +80°C -40 to +80°C -40 to +80°C -40 to +80°C -40 to +80°C Mounting Type Top-hat DIN rail or flat-mount Top-hat DIN rail or flat-mount Top-hat DIN rail or flat-mount Top-hat DIN rail or flat-mount Top-hat DIN rail or flat-mount Dimensions 120 x 54 x 19 mm 120 x 54 x 19 mm 120 x 54 x 19 mm 120 x 54 x 19 mm 120 x 54 x 19 mm Approvals Network rail approval (ESP 06E and ESP 15E). NRS PADS ref. 086/000201 (ESP 06E), 086/000200 (ESP 15E) Approvals UK Oftel NS/G/1235/W/100025 Transient Voltage Suppressors (Data Lines)
New items
ESP 240DS-10A, WJ Furse

ESP 240DS-10A, WJ Furse

WJ Furse Power distribution systems enhanced surge protector - ESP-D/ DS Series The D/ DS range offers a further enhanced series to the existing ESP range of mains protector range for specific systems, complementing the existing D1 Series. Having a low let through voltage combined with the mains test Type 1, 2 and 3 to BS EN 61643, the D/ DS series is designed for use on low current single phase systems (up to 10A or 32A) to protect against transient over voltages on the mains supply, and offering an increased exposure level covering lighting protection zones (LPZ) 0 -3. It also features a 3 way visual indication of protector status and advanced pre-failure warning, and remote indication facilities to a BMS via a volt-free contact. (DS Version) Features and Benefits: Combined type 1, 2 and 3 tested protector (to BS EN 61643) Low let through voltages Industry leading, enhanced protection to BS EN 62305 Compact DIN housing 3 way indication facility of protector status and advanced pre-failure warning Remote indication facility (DS Version) Protector’s offer repeated protection against transient over voltages Applications: The D/ DS range is for low current mains power supply applications, e.g. CCTV cameras, alarm panels, industrial battery chargers and telemetry equipment Surge Protection Devices, SPDs (DIN-rail) Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standa...
New items
ESP SL30X/I, WJ Furse

ESP SL30X/I, WJ Furse

Signalling applications surge protector for hazardous areas - ESP SLX Series Ultra-slim low-resistance enhanced surge protector suitable for hazardous area signalling applications II II 2(1)G, ia (ia Ga) IIC T4 Gb) Very low let-through voltage between all lines Very low (1Ω) in-line resistance High bandwidth Sturdy, flame retardant, polycarbonate housing Built-in DIN rail foot for easy installation With isolated screen Earthed through DIN rail foot or 4 sq mm earth terminal ESP SL15X ESP SL30X Max. Surge Current 10 kA 10 kA Max. Voltage Rating 16.7 V 36.7 V Operating Temp. Range -40 to +80°C -40 to +80°C Mounting Type Top-hat DIN rail or flat-mount Top-hat DIN rail or flat-mount Dimensions 106.5 x 104.6 x 7 mm 106.5 x 104.6 x 7 mm Approvals IECEx SIR 10.0030X, Sira 10ATEX2063X Transient Voltage Suppressors (Data Lines)
New items
7TCA083670R0690  LK245-12, WJ Furse

7TCA083670R0690 LK245-12, WJ Furse

Furse Standard Lightning Earth Bar Furse Lightning Earth Bars are an efficient and convenient way of providing a common earth point with integral disconnecting links which facilitate easy isolation for testing purposes. Features Facilitate multiple connections to earth Manufactured out of high conductivity 50 x 6 mm HD copper bar Corrosion proof PVC channel base Lighter and easier to handle No need for insulators M10 phosphor bronze stud assemblies Pre-drilled fixing holes for ease of installation
New items
7TCA083160R0054  ST200, WJ Furse

7TCA083160R0054 ST200, WJ Furse

Furse Lightning Earth Rod Driving Stud Furse Lightning Earth Rod Driving Stud enables the installer to put the earth rod into the ground. The driving stud is designed for driving copperbond threaded earth rods by hand or power hammer. Features 5⁄8” Driving Stud Applications Designed to be used in conjunction with a coupling to drive the earth rod into the ground and avoid damaging the threads of the rod Suitable for use with power hammers
New items
7TCA083670R0676  LK243-6, WJ Furse

7TCA083670R0676 LK243-6, WJ Furse

Furse Single Disconnecting Link Lightning Earth Bars Furse lightning earth bars with signle disconnecting links to facilitate multiple connections to earth with the option of isolating from either side of the earth bar for testing purposes are available in a range of different sizes and weight, all with the same height of 96 mm and width of 90 mm. Furse earth bars are manufactured from 50 mm x 6 mm copper bar. Features Facilitate multiple connections to earth Corrosion proof PVC channel base Lighter and easier to handle No need for insulators M10 phosphor bronze stud assemblies Pre-drilled fixing holes for ease of installation
New items
7TCA083120R0011  RB005, WJ Furse

7TCA083120R0011 RB005, WJ Furse

Furse Lightning Unthreaded Copperbond Earth Rod Furse Lightning Unthreaded Copperbond Earth Rod offers installers the most economical method of achieving a low earth resistance. Features High tensile strength Low carbon steel core Highly resistant to corrosion Copper thickness minimum 250 microns Applications Designed for use where extremely high corrosion resistance and long service life are required.
New items
7TCA085460R0112  ESP 415M1, WJ Furse

7TCA085460R0112 ESP 415M1, WJ Furse

Enhanced surge protector Accessories 456-8112 798-3539