Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Seaward Clare Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Seaward Clare




New Items
New items
H5004, Seaward Clare

H5004, Seaward Clare

HAL 101 The HAL 101 offers simple straightforward operation in a factory test or lab/compliance environment. Providing simple manual testing or complete automated operation, equipment can be tested quickly and safely. Fast automatic production testing using sequence capability Performs a.c./d.c. Flash and d.c. IR tests Fully isolated HT outputs for safe, high current flash testing complying with electrical safety testing standard, EN 50191 Internal storage of up to 6000 test results and test sequences Graphical representation of test voltage and pass fail limits on a 320 x 240 VGA graphical LCD Single button operation with simple PASS/FAIL indication Provides bar-code read facility for control of inventory Prints product ID and test reports, when connected to a printer Connects to external, high visibility status beacons Compatible with the BrainCell equipment tagging system (stock No. 409-9341 ) AC flash test Voltage range 0.10 to 5.00kV (programmable) Resolution 10V/Step (Settable) Voltage accuracy ±1% of reading AC leakage Max output current 20mA @ 5kV Display current range 0.01 to 20.00mA Display current resolution 0.01mA Pass levels 0.01 to 20.00mA Selectable Accuracy ±1% of reading DC flash test Test voltage range 0.10 to 6.00kV (Programmable) Frequency 50 or 60Hz (Independent of supply) Output voltage ripple Voltage selection resolution 10V/Step Voltage accuracy ±1% ±3 digits of reading DC leakage Max output current 10mA @ 6kV Display current range 0.01 to 10.00mA Display current resolution 0.01mA Pass levels 0.01 to 10.00mA Selectable Accuracy ±1% of reading Insulation resistance Test voltage 250V, 500V or 1000Vdc Trip current 10mA d.c. max Range 25kΩ to 1GΩ Resolution 0.01MΩ ( Accuracy ±5% of reading (25kΩ to 700MΩ) ±10% of reading (700MΩ to 1GΩ) Pass levels 25kΩ to 1GΩ Selectable Arc detection ...
New items
450A920, Seaward Clare

450A920, Seaward Clare

HAL 101 The HAL 101 offers simple straightforward operation in a factory test or lab/compliance environment. Providing simple manual testing or complete automated operation, equipment can be tested quickly and safely. Fast automatic production testing using sequence capability Performs a.c./d.c. Flash and d.c. IR tests Fully isolated HT outputs for safe, high current flash testing complying with electrical safety testing standard, EN 50191 Internal storage of up to 6000 test results and test sequences Graphical representation of test voltage and pass fail limits on a 320 x 240 VGA graphical LCD Single button operation with simple PASS/FAIL indication Provides bar-code read facility for control of inventory Prints product ID and test reports, when connected to a printer Connects to external, high visibility status beacons Compatible with the BrainCell equipment tagging system (stock No. 409-9341 ) AC flash test Voltage range 0.10 to 5.00kV (programmable) Resolution 10V/Step (Settable) Voltage accuracy ±1% of reading AC leakage Max output current 20mA @ 5kV Display current range 0.01 to 20.00mA Display current resolution 0.01mA Pass levels 0.01 to 20.00mA Selectable Accuracy ±1% of reading DC flash test Test voltage range 0.10 to 6.00kV (Programmable) Frequency 50 or 60Hz (Independent of supply) Output voltage ripple Voltage selection resolution 10V/Step Voltage accuracy ±1% ±3 digits of reading DC leakage Max output current 10mA @ 6kV Display current range 0.01 to 10.00mA Display current resolution 0.01mA Pass levels 0.01 to 10.00mA Selectable Accuracy ±1% of reading Insulation resistance Test voltage 250V, 500V or 1000Vdc Trip current 10mA d.c. max Range 25kΩ to 1GΩ Resolution 0.01MΩ ( Accuracy ±5% of reading (25kΩ to 700MΩ) ±10% of reading (700MΩ to 1GΩ) Pass levels 25kΩ to 1GΩ Selectable Arc detection ...