Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
PR Electronics Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For PR Electronics


Categories For PR Electronics




New Items
New items
9113BA, PR Electronics

9113BA, PR Electronics

9113B Type - Ex Temperature / mA Converter The 9113B is a temperature- and mA converter with 1- or 2-channels. The converter has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508. Ex temperature / mA converter for input for RTD, TC and mA 1-channel version, stock-no. 796-7045 2-channel version, stock-no. 796-7048 Conversion and scaling of temperature (Pt, Ni and TC) and active current signals TC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 / PR 5913Ex, channel 2) for higher accuracy Active / passive mA output SIL 2-certified via Full Assessment, the functionality is optional and must be activated in a menu point Configuration and monitoring by way of detachable display front (PR 4501); process calibration and signal simulation Copying of the configuration from one device to others of the same type via the display front Please order the Display Front PR4501 separately (stock-no. 796-6890 ) The device can be mounted in the safe area and in zone 2 / cl. 1 div. 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including M1 / Class I/II/III, Div. 1, Gr. A-G Front LEDs indicate operation status and malfunction 2.6 kVAC galvanic isolation between input, output and supply Can be supplied separately or installed on power rail, PR type 9400 PR Electronics - Ex Interfaces
New items
3225A, PR Electronics

3225A, PR Electronics

The PR Electronics Universal Frequency Converter units can be mounted side by side, horizontally and vertically, without air gap on a standard DIN rail, even at 70°C ambient temperature. All programming can be password protected. All terminals are over-voltage protected, polarity protected and short-circuit protected. The device is provided with field wiring terminals and shall be supplied from a power supply having double / reinforced. Insulation. a power switch should be easily accessible and close to the device. the power switch shall be marked as the disconnecting unit for the device. 2.5 kvac isolation Power supply 16.8 vdc,31.2 vdc Buffered voltage output 10 vdc Measures frequencies up to 100 kHz
New items
4510, PR Electronics

4510, PR Electronics

The PR Electronics Programming display has monitor process value and status from the built-in display. The easily readable 4510 display can be used to monitor the process signal, simulate the output signal, indicate sensor errors and internal module errors. It can be moved from one device to another. The individual system 3000/4000/9000 device configuration of a transmitter can be saved and downloaded to subsequent transmitters. Easy to read dot matrix LCD display Backup memory for load and save of module configuration Scrolling help text in 7 languages High 2.5 kV isolation to host unit
New items
5714A, PR Electronics

5714A, PR Electronics

5700 Series - Programmable LED Indicators Range of 5700 series Multi-functional Panel Meters are characterized by their flexibility and stability. The panel meters meet nearly every demand for display readout of process signals, and have universal input and supply capabilities. They provide a real-time measurement of your process value no matter the industry, and are engineered to provide a user-friendly, reliable relay of information, even in demanding environment The 5700 series are easily configured via PC, DIP switches or using built in push buttons on the front of the unit making deployment fast and simple. 4-digit 14-segment LED display Front key programmable, all standard operational parameters can be adjusted of the front function keys Help texts in eight languages available Display is easily scaled to the correct process value (from -9999 to 9999) Input for mA, V, Ohm, RTD, TC and potentiometer Relay output 5715 series: 4 x SPDT Relay output 5714A series: Standard Output Relay output 5714B series: 2 relays Relay output 5714C series: Analogue Output Relay output 5714D series: Analogue Output and 2 relays Analog output 0-20mA IP65 protection on the front For extra protection in extreme environments a splash-proof cover is available (stock-no.: 796-7010 ) PR Electronics Series
New items
5131AA, PR Electronics

5131AA, PR Electronics

5131A - 2-wire Programmable Transmitter The 5131A is a 2-wire programmable transmitter. The transmitter is for conversion of linear resistance variation to a standard analog current / voltage signal, for example from solenoids and butterfly valves or linear movements with attached potentiometer. This transmitter can be configured with the software program PReset using a standard PC and the Loop Link communications unit (stock-no. 796-7020 ). 2-wire programmable transmitter 1-channel, stock-no. 827-5491 2-channel, stock-no. 796-6893 Input for RTD, TC, mV, linear resistance, mA, and V sample Linearized, electronic temperature measurement with RTD or TC sensor 4- or 3-wire connection automatic cable compensation or 2-wire connection with programmable cable compensation Current input programmable in range 0-100 mA and voltage inputs in range 0-250 Vdc 4-20 mA loop output, can be configured to any current within 0-20 mA range Voltage output range is selectable between 0-10 Vdc Independent channel jumper selectable inputs for current/voltage or temperature Programming can be performed with or without a power supply 3.75 kVac galvanic isolation between the channels Configurable sensor error detection including NAMUR NE43 DIN rail mounting Temperature Transmitters 4 to 20mA loop powered output and reverse polarity protection, configurable without the need for a PC or software
New items
3114, PR Electronics

3114, PR Electronics

3100 Type - Isolated Converter 3104, 3109 and 3114 type are for isolation and conversion of standard DC signals. Suitable for galvanic separation of analog DC signals and elimination of ground loops and measurement of floating signals. Conversion of standard DC signals Slimline housing of 6 mm Power supply and signal isolator for 2-wire transmitter Loop supply >17 V DIP-switch configured Inputs and outputs are floating and galvanically separated Isolation 2.5 mm Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2 PR Electronics DIN Rail Mounting
New items
6331A2A, PR Electronics

6331A2A, PR Electronics

6331A - 2-wire Programmable Transmitter The 6331A is a 2-wire programmable transmitter. The transmitter is for conversion of linear resistance variation to a standard analog current signal, for instance from valves or ohmic level sensors. 2-wire Programmable Transmitter 1-channel version, stock-no. 827-5508 2-channel version, stock-no. 796-6922 Amplification of a bipolar mV signal to a standard 4-20 mA current signal RTD, TC, Ohm or mV input Linearized temperature measurement with Pt, Ni or TC sensor RTD and resistance inputs have cable compensation for 2-, 3- and 4-wire connection Programmable sensor error value A limit can be programmed on the output signal Extremely high measurement accuracy Galvanic isolation DIN rail mounting Temperature Transmitters 4 to 20mA loop powered output and reverse polarity protection, configurable without the need for a PC or software
New items
3225B, PR Electronics

3225B, PR Electronics

The PR Electronics Universal Frequency Converter units can be mounted side by side, horizontally and vertically, without air gap on a standard DIN rail, even at 70°C ambient temperature. All programming can be password protected. All terminals are over-voltage protected, polarity protected and short-circuit protected. The device is provided with field wiring terminals and shall be supplied from a power supply having double / reinforced. Insulation. a power switch should be easily accessible and close to the device. the power switch shall be marked as the disconnecting unit for the device. 2.5 kvac isolation Power supply 16.8 vdc,31.2 vdc Buffered voltage output 10 vdc Measures frequencies up to 100 kHz
New items
6337A2A, PR Electronics

6337A2A, PR Electronics

6337A 2-Wire HART Transmitter 2-wire HART transmitter is designed according to strict safety requirements and is suitable for applications in SIL installations. Features and Benefits 2 Analogue inputs and 5 device selectable variables with status available HART protocol revision selectable from HART 5 or HART 7 1 ( 136-8682 ) or 2 ( 136-8683 ) channel converter for RTD, TC, Ohm and bipolar mV signals Continuous check of vital stored data Linearised temperature measurement with TC and RTD sensors HART communication and 4…20 mA analogue PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors Conversation of linear resistance to a standard analogue current signal Amplification of bipolar mV signals to standard 4…20 mA current signals Up to 63 transmitters (HART 7) can be connected in a multi-drop communication setup DIN Rail mounting in Safe Area or Zone 2/22 Meets NAMUR NE 21, NE43 and NE89 recommendations and ensures top measurements performance in harsh EMC environments Temperature Transmitters 4 to 20mA loop powered output and reverse polarity protection, configurable without the need for a PC or software
New items
5531B1, PR Electronics

5531B1, PR Electronics

5500 Series - Loop-powered LCD Indicator 5531 series loop powered indicators with a 4-digit LCD display. It can be mounted in the safe area. 4 digit loop-powered LCD display Indicator is powered by the 4 to 20 mA current loop LCD backlight can be set to half or full intensity for easy viewing in low light conditions Display is easily scaled to the correct process value (from -9999 to 9999) Easy push-button configuration Front push-buttons can be disabled to prevent unauthorized adjustment 5531A can be panel mounted in the safe area or I.S. / Ex Zone 2 (gas) (stock-no.: 796-6938 ) 5531B can be mounted in Ex Zone 0 (stock-no.: 796-7073 ) 5531B1 can be mounted in Ex Zone 2 and 22 (stock-no.: 827-5410 ) 5531B2 can be mounted in Ex Zone 1, 2, 21 and 22 (stock-no.: 827-5413 ) PR Electronics Series
New items
2261, PR Electronics

2261, PR Electronics

2261 Type - mV Transmitter The 2261 mV Transmitter converts bipolar mV signals from transducers supplied directly by the device to standard current / voltage signals.The device is also suitable for load cell application as well as other applications such as tank filling and draining, weighing with a taring function, measurement of cable tensile force, level control, signal conversion / amplification etc. Load cell amplifiermV to current / voltage conversionFront-programmableLED displayFront error LEDRelative calibration of input spanNPN / PNP input for external taringSupply for standard transducersPR Electronics DIN Rail Mounting