Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
PMA Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For PMA




New Items
New items
BVBD-P167GT, PMA

BVBD-P167GT, PMA

90° Curved Elbow Black high shock resistant, push-in fittings designed for use with PMAFLEX conduits, manufactured from modified Polyamides. They have a locking feature which prevents unauthorised removal by the need to use a screwdriver to reopen, these fittings can be used in a wide range of applications where it is important that the cable protection system offers a high grade of sealing and safety. One-piece, vibration free connection, featuring a smooth bore allowing easy threading of wires and cables, supplied with locknut. PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL
New items
PECO-23B, PMA

PECO-23B, PMA

Contractor Packs IP66, halogen-free flexible conduit Contractor packs, each comprising 10 metres of Ecoflex conduit, 10 straight fittings, 10 locknuts Self extinguishing Resistant to: fuels, mineral oils, lubricants, alkalis, and most common solvents Operating temp. -30°C to +105°C for polypropylene, -40°C to +105°C for polyamide
New items
SLND-M329, PMA

SLND-M329, PMA

Fittings IP66 (with Fittings) -20°C to +100°C operating temperature Halogen & Phosphor free UL94 Flame Class Push-in fittings are one piece with integral cone seal and have a screwdriver release mechanism for security reasons Resistant to: fuels, mineral oils, fats, alkalis & common solvents
New items
BVND-EVM207GT, PMA

BVND-EVM207GT, PMA

Panel Mount Black high shock resistant, push-in fitting designed for use with PMAFLEX conduits, manufactured from modified Polyamides. They have a locking feature which prevents unauthorised removal by the need to use a screwdriver to reopen, these fittings can be used in a wide range of applications where it is important that the cable protection system offers a high grade of sealing and safety. Panel Mount fittings are a one piece quick and easy connection (no locking nut required to secure in place) that simply push fit into a panel or enclosure with a wall thickness of between 1.7-2.3mm. Cut-out diameter for 16mm = 16.5mm, 20mm = 20.5mm, 25mm = 25.5mm. PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL
New items
F.66.12.SW, PMA

F.66.12.SW, PMA

F.66 Braided Hose This braided sleeving is manufactured from resilient polyamide and provides excellent protection against abrasion. It is ideal for use with hoses, chains, cables and fittings in a range of applications. The sleeving can be secured in place using cable ties. It is highly flexible and easy to apply, even over irregular shapes. Features and Benefits Flexible and lightweight Abrasion resistant Stable in high temperatures Halogen free Self-extinguishing to UL94 V2 rating Applications Industrial, aviation, vehicle construction and rail.
New items
PIST-23B, PMA

PIST-23B, PMA

Medium Duty Flexible Conduit Excellent flexibility High-grade, specially formulated polyamide 12 Good mechanical strength at low temperatures and dry conditions Excellent resistance to ultra violet rays and atmospheric corrosion Self-extinguishing NMPT-C For dynamic applications in robotics and automation Compatible with PMAFIX, PMAFIX Pro, PMA Smart Line, PMAGRIP PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL
New items
VOHG-29B, PMA

VOHG-29B, PMA

UL Extra Heavy Duty Conduit - VOH UL Extra Heavy Duty VOH (Black) conduits offer high mechanical strength, along with high stiffness and pull-out resistance, these conduits can be used in machines and installations internally and externally. Due to the heavy construction and the very good flame properties the grey heavy duty conduit can also be used within the traction industry, vehicle and building construction. They are heavy walled and manufactured from modified Polyamide. Approvals UL recognised PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL
New items
PIST-29B, PMA

PIST-29B, PMA

Medium Duty Flexible Conduit Excellent flexibility High-grade, specially formulated polyamide 12 Good mechanical strength at low temperatures and dry conditions Excellent resistance to ultra violet rays and atmospheric corrosion Self-extinguishing NMPT-C For dynamic applications in robotics and automation Compatible with PMAFIX, PMAFIX Pro, PMA Smart Line, PMAGRIP PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL
New items
SVND-M508GT, PMA

SVND-M508GT, PMA

Straight Fittings A selection of high shock resistant, push-in fittings designed for use with PMAFLEX conduits, manufactured from modified Polyamides. They have a locking feature which prevents unauthorised removal by the need to use a screwdriver to reopen, these fittings can be used in a wide range of applications where it is important that the cable protection system offers a high grade of sealing and safety. Note Supplied with locknuts and gripping clip. PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL
New items
BFH-17-0, PMA

BFH-17-0, PMA

Conduit Clip One-piece Conduit Clips feature an integrated safety clip (reopened with a screwdriver), single hole fixing and offer optimal strain relief due to integrated rib, they can be used to support all PMA conduits in machine and overhead installations. PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL
New items
LL-17S, PMA

LL-17S, PMA

Flexible Polypropylene Economical very flexible, medium duty polypropylene (inherently flame retardant) conduit generally used for the protection of electrical wiring in the vehicle and machine building industries and for installation applications. IP66 (with Fittings) -20°C to +90°C operating temperature (+130°C short term) Halogen & Cadmium free UL94-HB flame class Self extinguishing Pull off Strength >100N Impact Strength 4J Resistant to: strong acids
New items
CF-23B, PMA

CF-23B, PMA

Extra Flexible Nylon - CF The CF conduits are extra flexible medium wall black conduits, produced from specially modified polyamide (PA6). The material of the CF conduits is self-extinguishing and free of halogen and cadmium. These Medium-wall conduits are very economical and offer good impact resistance and flexibility. Ideal applications of the medium-wall conduits are in machine building and installation industries. -40°C to +105°C operating temperature Halogen and Cadmium free Self-Extinguishing Pull off Strength >150N Impact Strength >5J Approvals CF, UL Standards UL50086, EN 50086 PMAFLEX Polyamide & Polyurethane (IP68/66) Features for all conduit types: IP68/66 (dependent upon Fittings) Halogen & Cadmium free None flame propagating Resistant to: fuels, mineral oils, lubricants, alkalies and most common solvents PCL: -40°C to +105°C operating temperature (+150°C short term), Impact strength >6J, flame class UL94 V2, CSA approved PUE: -60°C to +50°C operating temperature, excellent reversed bending properties VOH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >20J, UL rec PAH: -40°C to 105°C operating temperature (+150°C short term), Impact strength >18J VAML/VAM: -40°C to 105°C operating temperature (+150°C short term) PCS: -40°C to +105°C operating temperature (+150°C short term), Impact strength >7.5J, CSA approval , UL