Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Peppers Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Peppers




New Items
New items
AR0BF/050NPT/M20, Peppers

AR0BF/050NPT/M20, Peppers

The Peppers AR Series Certified Adaptors & Reducers provide a method of matching electrical thread forms on Ex equipment whilst maintaining Ex db, Ex eb, Ex ta and Ex nR methods of explosion protection. Approved for use in mining (except Aluminium) and surface installations, they maintain IP66 & IP68 for IEC type applications and Class I Division 1 and NEMA 4X for CEC / NEC type applications. All external metric threads are fitted with a nitrile O-ring as standard. -100°C to +400°C operating temperature Brass materials Electroless Nickel plating
New items
SPMH3BF/M40, Peppers

SPMH3BF/M40, Peppers

The Peppers SPMH & SPHH Series Certified Metallic Stopping (Blanking) Plugs provide a method of sealing unused entries in Ex equipment. They maintain Ex db, Ex eb, Ex tb and Ex nR methods of protection and IP66, IP68 for IEC type applications. They are Class I Division 1, Class II Division 1, Class II and Class 1 Zone 1 approved for NEC and CEC type applications whilst also maintain Type 4X rating. -60°C to +200°C operating temperature Brass materials Electroless Nickel plating
New items
A2LSFK1/25/M25, Peppers

A2LSFK1/25/M25, Peppers

IP68 Metric Stainless Steel A2LF Gland The IP68 metric stainless steel gland provides a controlled pull resistant environmental displacement seal on cables outer sheaths. This minimises damage to cold flow characteristic cables. The glands maintain IP66 and IP68 up to 25 m. They are also deluge proof without using any additional seals or deluge boots. Features and Benefits • For use with PVC/PVC PILC/PVC XPLE/PVC Cables • Stainless steel flameproof gland reference A2LF • Intended for use with non-armoured cables • Approval certificate available on request Supplied with Locknut, earth tag, integral O ring seal and black PCP shroud.
New items
E1WFK2/20/M20, Peppers

E1WFK2/20/M20, Peppers

Peppers IP66 Metric Flameproof Cable Glands The Peppers brass flame proof cable glands, type EIW are intended for use with SWA cables and suitable for indoor, outdoor and hazardous environments. The glands are suitable for use in Zone1, Zone2, Zone 21, zone 22 and in Gas Group IIA, IIB and IIC. Supplied with Two brass glands , copper earth tags, brass lock nuts, IP66 entry thread seals and PCP shrouds. Approvals SIRA 01 ATEX 1271X
New items
AR3BF/M20/075NPT, Peppers

AR3BF/M20/075NPT, Peppers

The Peppers AR Series Certified Adaptors & Reducers provide a method of matching electrical thread forms on Ex equipment whilst maintaining Ex db, Ex eb, Ex ta and Ex nR methods of explosion protection. Approved for use in mining (except Aluminium) and surface installations, they maintain IP66 & IP68 for IEC type applications and Class I Division 1 and NEMA 4X for CEC / NEC type applications. All external metric threads are fitted with a nitrile O-ring as standard. -60°C to +200°C operating temperature Brass materials Electroless Nickel plating
New items
ACDP1SE/M20/10, Peppers

ACDP1SE/M20/10, Peppers

The Peppers ACDP Series Breather Drains allow the inside of the equipment to breathe with the outside atmosphere and provide a method of effectively draining any moisture from within the equipment. ACDP series Breather Drains maintain Ex e method of protection and IP66 for IEC type applications. A Castellated Locknut and O-ring is supplied with every Breather Drain. -30°C to +100°C operating temperature Stainless Steel materials Electroless Nickel plating
New items
SPMH3BF/075NPT, Peppers

SPMH3BF/075NPT, Peppers

The Peppers SPMH & SPHH Series Certified Metallic Stopping (Blanking) Plugs provide a method of sealing unused entries in Ex equipment. They maintain Ex db, Ex eb, Ex tb and Ex nR methods of protection and IP66, IP68 for IEC type applications. They are Class I Division 1, Class II Division 1, Class II and Class 1 Zone 1 approved for NEC and CEC type applications whilst also maintain Type 4X rating. -60°C to +200°C operating temperature Brass materials Electroless Nickel plating
New items
AR3BF/M20/M25, Peppers

AR3BF/M20/M25, Peppers

The Peppers AR Series Certified Adaptors & Reducers provide a method of matching electrical thread forms on Ex equipment whilst maintaining Ex db, Ex eb, Ex ta and Ex nR methods of explosion protection. Approved for use in mining (except Aluminium) and surface installations, they maintain IP66 & IP68 for IEC type applications and Class I Division 1 and NEMA 4X for CEC / NEC type applications. All external metric threads are fitted with a nitrile O-ring as standard. -60°C to +200°C operating temperature Brass materials Electroless Nickel plating
New items
AR3BF/M25/100NPT, Peppers

AR3BF/M25/100NPT, Peppers

The Peppers AR Series Certified Adaptors & Reducers provide a method of matching electrical thread forms on Ex equipment whilst maintaining Ex db, Ex eb, Ex ta and Ex nR methods of explosion protection. Approved for use in mining (except Aluminium) and surface installations, they maintain IP66 & IP68 for IEC type applications and Class I Division 1 and NEMA 4X for CEC / NEC type applications. All external metric threads are fitted with a nitrile O-ring as standard. -60°C to +200°C operating temperature Brass materials Electroless Nickel plating
New items
AR3BF/M25/M20, Peppers

AR3BF/M25/M20, Peppers

The Peppers AR Series Certified Adaptors & Reducers provide a method of matching electrical thread forms on Ex equipment whilst maintaining Ex db, Ex eb, Ex ta and Ex nR methods of explosion protection. Approved for use in mining (except Aluminium) and surface installations, they maintain IP66 & IP68 for IEC type applications and Class I Division 1 and NEMA 4X for CEC / NEC type applications. All external metric threads are fitted with a nitrile O-ring as standard. -60°C to +200°C operating temperature Brass materials Electroless Nickel plating
New items
E1WFK2/25/M25, Peppers

E1WFK2/25/M25, Peppers

Peppers IP66 Metric Flameproof Cable Glands The Peppers brass flame proof cable glands, type EIW are intended for use with SWA cables and suitable for indoor, outdoor and hazardous environments. The glands are suitable for use in Zone1, Zone2, Zone 21, zone 22 and in Gas Group IIA, IIB and IIC. Supplied with Two brass glands , copper earth tags, brass lock nuts, IP66 entry thread seals and PCP shrouds. Approvals SIRA 01 ATEX 1271X
New items
E1WFK2/20S/M20, Peppers

E1WFK2/20S/M20, Peppers

Peppers IP66 Metric Flameproof Cable Glands The Peppers brass flame proof cable glands, type EIW are intended for use with SWA cables and suitable for indoor, outdoor and hazardous environments. The glands are suitable for use in Zone1, Zone2, Zone 21, zone 22 and in Gas Group IIA, IIB and IIC. Supplied with Two brass glands , copper earth tags, brass lock nuts, IP66 entry thread seals and PCP shrouds. Approvals SIRA 01 ATEX 1271X