Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Kewtech Corporation Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Kewtech Corporation


Categories For Kewtech Corporation




New Items
New items
TC5, Kewtech Corporation

TC5, Kewtech Corporation

TC5 Electrical Installation Test and Inspection Certificates The Kewtech range of 17th Edition certification books are fully up to date and comply to BS7671 amendment 3. The family tree is split into two streams, new installations and existing installations. The testing results schedules are common to both streams. TC5 is the Schedule of Test Results for up to 12 ways. It is used with the Electrical Installation Certificate (New Installations) TC1 & TC8. And with the Electrical Installation Condition Reports (existing installations) TC3 & TC4. All pages are duplicated. New Installations For incoming supplies up to 100 A use TC1 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC8 plus the results pages either TC5 or TC6 Existing Installations (Electrical Installation Condition Report) For incoming supplies up to 100 A use TC3 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC4 plus the results pages either TC5 or TC6 For extra observations use TC7 (optional) Testing Schedule (results sheets) For up to 12 ways use TC5 For greater than 12 ways use TC6 For Minor Works Use TC2 - This is a standalone certificate No of Cert: 40 Pages / Cert: 1 No of sheets Inc. copies: 80 Standards Complies to BS 7617 Amendment 3 Electrical Installation Testers and Accessories
New items
TC8, Kewtech Corporation

TC8, Kewtech Corporation

TC8 Electrical Installation Test and Inspection Certificates The Kewtech range of 17th Edition certification books are fully up to date and comply to BS7671 amendment 3. The family tree is split into two streams, new installations and existing installations. The testing results schedules are common to both streams. TC8 is an Electrical Installation Certificate for premises with over 100 A incoming supply. Use with TC5 Schedule of Testing Results for up to 12 ways or TC6 for greater than 12 ways. All pages are duplicated. New Installations For incoming supplies up to 100 A use TC1 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC8 plus the results pages either TC5 or TC6 Existing Installations (Electrical Installation Condition Report) For incoming supplies up to 100 A use TC3 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC4 plus the results pages either TC5 or TC6 For extra observations use TC7 (optional) Testing Schedule (results sheets) For up to 12 ways use TC5 For greater than 12 ways use TC6 For Minor Works Use TC2 - this is a standalone certificate No of Cert: 7 Pages / Cert: 6 No of sheets Inc. copies: 84 Standards Complies to BS 7617 Amendment 3 Electrical Installation Testers and Accessories
New items
TC4, Kewtech Corporation

TC4, Kewtech Corporation

TC4 Electrical Installation Test and Inspection Certificates The Kewtech range of 17th Edition certification books are fully up to date and comply with BS7671 amendment 3. The family tree is split into two streams, new installations and existing installations. The testing results schedules are common to both streams. TC4 is an Electrical Installation Condition Report for premises with over 100 A supply. Use with TC5 Schedule of Test Results for up to 12 ways or TC6 for greater than 12 ways. Also for extra observations use the optional TC7. All pages are duplicated. New Installations For incoming supplies up to 100 A use TC1 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC8 plus the results pages either TC5 or TC6 Existing Installations (Electrical Installation Condition Report) For incoming supplies up to 100 A, use TC3 plus the results pages either TC5 or TC6 For incoming supplies over 100 A, use TC4 plus the results pages either TC5 or TC6 For extra observations use TC7 (optional) Testing Schedule (results sheets) For up to 12 ways use TC5 For greater than 12 ways use TC6 For Minor Works Use TC2 - This is a standalone certificate No of Cert: 7 Pages / Cert: 6 No of sheets Inc. copies: 84 Standards Complies to BS 7617 Amendment 3 Electrical Installation Testers and Accessories
New items
TC3, Kewtech Corporation

TC3, Kewtech Corporation

TC3 Electrical Installation Test and Inspection Certificates The Kewtech range of 17th Edition certification books are fully up to date and comply with BS7671 amendment 3. All pages are duplicated (carbonless paper). The family tree is split into two streams, new installations and existing installations. The testing results schedules are common to both streams. TC3 is an Electrical Installation Condition Report for domestic or similar premises up to 100 A supply. Use with TC5 Schedule of Test Results for up to 12 ways or TC6 for greater than 12 ways. Also for extra observations use the optional TC7. New Installations For incoming supplies up to 100 A use TC1 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC8 plus the results pages either TC5 or TC6 Existing Installations (Electrical Installation Condition Report) For incoming supplies up to 100 A use TC3 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC4 plus the results pages either TC5 or TC6 For extra observations use TC7 (optional) Testing Schedule (results sheets) For up to 12 ways use TC5 For greater than 12 ways use TC6 For Minor Works Use TC2 - This is a standalone certificate No of Cert: 8 Pages / Cert: 5 No of sheets Inc. copies: 80 Standards Complies to BS 7617 Amendment 3 Electrical Installation Testers and Accessories
New items
EL KIT, Kewtech Corporation

EL KIT, Kewtech Corporation

PAT Tester 110V, 240V, 400V Adaptor UK Version PAT Tester 110V, 240V, 400V Adaptor UK Version. Kit contents: EL230 For use with all Kewtech Pat Testers For testing industrial 16A 230V appliances and extension leads Used for earth bond testing and insulation testing EL415 For use with all Kewtech Pat Testers For earth bond and insulation testing of 3 phase 400V appliances EL110PATKIT For testing 110V extension leads For earth bond and insulation testing of 110V appliances Electrical Installation Testers and Accessories
New items
FC2000, Kewtech Corporation

FC2000, Kewtech Corporation

Kewtech FC2000 Calibration Check Box The FC2000 Calibration Checkbox allows electricians to check their own 17th Edition test equipment and ensure that all meters are operating correctly and accurately. The Kewtech FC2000 Check Box doesn't replace the calibration requirements of testers but provides a quick and simple way to check instrument accuracy, reducing the risk of incorrect certification. Checks that 17th edition testers are maintaining their calibration Test lead nulling point Three continuity test points Three Insulation test points Two loop impedance test points plus the local loop 1/2, x 1, x 5 30mA current and time test settings Supplied with Mains lead, instruction manual.
New items
TC1, Kewtech Corporation

TC1, Kewtech Corporation

TC1 Electrical Installation Test and Inspection Certificates The Kewtech range of 17th Edition certification books are fully up to date and comply to BS7671 amendment 3. All pages are duplicated (carbonless paper). The family tree is split into two streams, new installations and existing installations. The testing results schedules are common to both streams. TC1 is an Electrical Installation Certificate for domestic or similar premises up to 100 A incoming supply. Use with TC5 Schedule of Testing Results for up to 12 ways or TC6 for greater than 12 ways. All pages are duplicated. New Installations For incoming supplies up to 100 A use TC1 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC8 plus the results pages either TC5 or TC6 Existing Installations (Electrical Installation Condition Report) For incoming supplies up to 10 0A use TC3 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC4 plus the results pages either TC5 or TC6 For extra observations, use TC7 (optional) Testing Schedule (results sheets) For up to 12 ways, use TC5 For greater than 12 ways,, use TC6 For Minor Works Use TC2 - This is a standalone certificate No of Cert: 10 Pages / Cert: 4 No of sheets Inc. copies: 80 Standards Complies to BS 7617 Amendment 3 Electrical Installation Testers and Accessories
New items
TC6, Kewtech Corporation

TC6, Kewtech Corporation

TC6 Electrical Installation Test and Inspection Certificates The Kewtech range of 17th Edition certification books are fully up to date and comply to BS7671 amendment 3. The family tree is split into two streams, new installations and existing installations. The testing results schedules are common to both streams. TC6 is the Schedule of Test Results for over 12 ways. It is used with the Electrical Installation Certificate (New Installations) TC1 & TC8. And with the Electrical Installation Condition Reports (existing installations) TC3 & TC4. All pages are duplicated. New Installations For incoming supplies up to 100 A use TC1 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC8 plus the results pages either TC5 or TC6 Existing Installations (Electrical Installation Condition Report) For incoming supplies up to 100 A use TC3 plus the results pages either TC5 or TC6 For incoming supplies over 100 A use TC4 plus the results pages either TC5 or TC6 For extra observations use TC7 (optional) Testing Schedule (results sheets) For up to 12 ways use TC5 For greater than 12 ways use TC6 For Minor Works Use TC2 - This is a standalone certificate No of Cert: 20 Pages / Cert: 2 No of sheets Inc. copies: 80 Standards Complies to BS 7617 Amendment 3 Electrical Installation Testers and Accessories
New items
KEWSTICK DUO, Kewtech Corporation

KEWSTICK DUO, Kewtech Corporation

Kewstick Duo Voltage Detector Pen The Kewstick Duo is a non-contact voltage detector that provides rapid indication of voltage from 90V to 600V AC, complete with dual sensitivity. The Kewstick Duo Voltage Detector is also useful for tracing and identifying live conductors in bunched or crowded cables. Simply hold down sensitivity attenuation button to reduce the sensitivity of the voltage detector. This feature enables to differentiate between live and earthed cables. Clearly detects 90 - 600 volts AC without metal contact Two colour LEDs - Green for correct working and Red for Voltage detection Two tone buzzer, one for correct working and one for voltage detection Pocket-size for handy use anywhere Low power consumption circuits means long life batteries Standards BSEN 61010 CAT IV 600V Supplied with 2 x AAA batteries.
New items
R2Check FL, Kewtech Corporation

R2Check FL, Kewtech Corporation

Kewcheck R2FL The Kewcheck R2FL testing adaptor comes with a flying lead to make fast connections to any connector of your choice. Specialist lighting connectors and 5 amp plugs. Just wire on your own choice of plug and the Kewchech R2FL will enable fast and secure connections of your 4mm test leads for loop and R1 & R2 measurements With flying lead allows r1 and r2 testing of Plug in ceiling roses, 2amp, 5amp and 15amp sockets as well as non standard power sockets
New items
R2CHECK, Kewtech Corporation

R2CHECK, Kewtech Corporation

Mains Socket Access Plug Plug allows ready access to UK 13A mains socket pins Shrouded 4mm sockets to BS1363 UK mains socket test adaptor Provides safe test connection to mains circuit for Live (phase), Neutral and Earth (ground) Enables fast electrical testing at mains sockets without removing the socket from the wall Note Compatible for use with test equipment and connection leads rated EN61010 CAT III 300V or greater only Note This socket is an adaptor for testing, it is not a tester
New items
PAT Adaptor 1, Kewtech Corporation

PAT Adaptor 1, Kewtech Corporation

Pat Adapter 1 Enables easy Pat Testing with an Insulation / Continuity Tester or a Multifunction Tester. Covers all the mandatory tests demanded by the Code of Practice Tests extension leads (in conjunction with the Kewtech R2) The new Code of Practice allows for 250V insulation tests (a replacement for leakage tests) Works with all testers that use 4mm test leads including Megger and Fluke Class 1: Earth Bond: Using a continuity tester for all appliances (including IT) Insulation: at 500V or 250V using an Insulation Tester Class 2: Insulation at 500V or 250V using an Insulation Tester