Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Elditest Profile

ELDITEST is a world-renowned manufacturing brand that develops and provides a complete variety of measurement and test accessories created to meet the requirements of designers, technicians, and engineers. Widely used products manufactured and supplied by the company include current clamp meters, patch cords, connectors, plugs, & sockets, coaxial cables and adapters, grabbers & alligator clips, oscilloscope probes, test tips & test leads, 2mm and SMD accessories are some of the most prominent high-quality accessories used by millions of customers globally.
Today, the company operates under the banner of Sefram, a multinational firm established in 1947 and is a subsidiary of BK Precision, striving to bring high-quality test and measurement products for electrical and electronic applications with innovation to the global market.

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Elditest




New Items
New items
915003150, Elditest

915003150, Elditest

1500 series mini data loggers Complete range of mini data loggers for all temperature, humidity, and industrial parameter monitoring applications. Logs saved for more than 2 years (memory capacity: 21,600 measurements or 43,300 for LOG 1550 K1 model). Possibility of recovering data without interrupting recording. Programming of recording start and end date. Remote controlled start/stop. Monitoring of industrial process parameters. 4-20 mA and 0-10 V loop monitoring. PC-based real time acquisition. Infrared interface. Windows-based software. Common characteristics: SEFRAM LOG 1501P Number of channels: 1 Measurement type: Internal temperature Range of measurement: -40°C → +85°C Accuracy: ±1 °C PDA compatibility: yes SEFRAM LOG 1510-K Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -50 °C to +150 °C (Te) Accuracy: ±1 °C (Ti) - ±0.5 °C + 1 °C (Te) SEFRAM LOG 1510-K1 Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -100 °C to +1200 °C (Te) Accuracy: ±1 °C (Ti) - ±2 °C + 1 °C (Te) SEFRAM LOG 1520P Number of channels: 2 Measurement type: Internal temperature, humidity Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 5% to 95% (HR) Accuracy: ±3% PDA compatibility: yes SEFRAM LOG 1520-K Number of channels: 3 Measurement type: -40 °C to 85 °C (Ti) -50 °C to 150 °C (Te) Accuracy: ±1 °C (Ti) ±0.5 °C (Te) Range of measurement: 5% to 95% (HR) Accuracy: ±3% Common characteristics: SEFRAM LOG 1525 Number of channels: 2 Measurement type: Internal temperature, DC voltage Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 2.5 V / 10 V / 25 V (DC.) Accuracy: ±0.1% SEFRAM LOG 1550-K1 Number of channels: 5 Memory holds 43,300 measur...
New items
SI 659, Elditest

SI 659, Elditest

1500 series mini data loggers Complete range of mini data loggers for all temperature, humidity, and industrial parameter monitoring applications. Logs saved for more than 2 years (memory capacity: 21,600 measurements or 43,300 for LOG 1550 K1 model). Possibility of recovering data without interrupting recording. Programming of recording start and end date. Remote controlled start/stop. Monitoring of industrial process parameters. 4-20 mA and 0-10 V loop monitoring. PC-based real time acquisition. Infrared interface. Windows-based software. Common characteristics: SEFRAM LOG 1501P Number of channels: 1 Measurement type: Internal temperature Range of measurement: -40°C → +85°C Accuracy: ±1 °C PDA compatibility: yes SEFRAM LOG 1510-K Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -50 °C to +150 °C (Te) Accuracy: ±1 °C (Ti) - ±0.5 °C + 1 °C (Te) SEFRAM LOG 1510-K1 Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -100 °C to +1200 °C (Te) Accuracy: ±1 °C (Ti) - ±2 °C + 1 °C (Te) SEFRAM LOG 1520P Number of channels: 2 Measurement type: Internal temperature, humidity Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 5% to 95% (HR) Accuracy: ±3% PDA compatibility: yes SEFRAM LOG 1520-K Number of channels: 3 Measurement type: -40 °C to 85 °C (Ti) -50 °C to 150 °C (Te) Accuracy: ±1 °C (Ti) ±0.5 °C (Te) Range of measurement: 5% to 95% (HR) Accuracy: ±3% Common characteristics: SEFRAM LOG 1525 Number of channels: 2 Measurement type: Internal temperature, DC voltage Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 2.5 V / 10 V / 25 V (DC.) Accuracy: ±0.1% SEFRAM LOG 1550-K1 Number of channels: 5 Memory holds 43,300 measur...
New items
1525-1, Elditest

1525-1, Elditest

1500 series mini data loggers Complete range of mini data loggers for all temperature, humidity, and industrial parameter monitoring applications. Logs saved for more than 2 years (memory capacity: 21,600 measurements or 43,300 for LOG 1550 K1 model). Possibility of recovering data without interrupting recording. Programming of recording start and end date. Remote controlled start/stop. Monitoring of industrial process parameters. 4-20 mA and 0-10 V loop monitoring. PC-based real time acquisition. Infrared interface. Windows-based software. Common characteristics: SEFRAM LOG 1501P Number of channels: 1 Measurement type: Internal temperature Range of measurement: -40°C → +85°C Accuracy: ±1 °C PDA compatibility: yes SEFRAM LOG 1510-K Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -50 °C to +150 °C (Te) Accuracy: ±1 °C (Ti) - ±0.5 °C + 1 °C (Te) SEFRAM LOG 1510-K1 Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -100 °C to +1200 °C (Te) Accuracy: ±1 °C (Ti) - ±2 °C + 1 °C (Te) SEFRAM LOG 1520P Number of channels: 2 Measurement type: Internal temperature, humidity Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 5% to 95% (HR) Accuracy: ±3% PDA compatibility: yes SEFRAM LOG 1520-K Number of channels: 3 Measurement type: -40 °C to 85 °C (Ti) -50 °C to 150 °C (Te) Accuracy: ±1 °C (Ti) ±0.5 °C (Te) Range of measurement: 5% to 95% (HR) Accuracy: ±3% Common characteristics: SEFRAM LOG 1525 Number of channels: 2 Measurement type: Internal temperature, DC voltage Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 2.5 V / 10 V / 25 V (DC.) Accuracy: ±0.1% SEFRAM LOG 1550-K1 Number of channels: 5 Memory holds 43,300 measur...
New items
GE 3830, Elditest

GE 3830, Elditest

High voltage probe - GE 3830 High voltage probes for oscilloscopes, for voltage measurement of up to 30kV. BNC connection and crocodile clip for earth conductor. This probe must be used by those qualified to work with earthed appliances. Max. input voltage: 30 kV AC and Vdc Bandwidth: 3 MHz Attenuation: x 1000 Input impedance: 500 MΩ / 3 pF Cable length: 2 m Standards IEC 1010, 30 kV Cat. II
New items
GE 7011, Elditest

GE 7011, Elditest

Demodulator probe Compact probe for oscilloscopes. On radiofrequency circuits, this probe allows the carrier to be removed and allows for measurements within the modulated signal. This probe must be used with an earthed measuring device. Min. input voltage: 0.2 V Max. input voltage: 600 Vac and Vdc Bandwidth: 0.1 → 800 MHz Input impedance: 5 pF Max. voltage of the frequency: 50 V peak Compensation range: 10 → 30 pF Wire length: 1.2 m Standards IEC 1010, 300 V Cat. I Passive Oscilloscope Probes Note All the products in this range are supplied for use with instruments with a permanent earth connection.
New items
SI 683, Elditest

SI 683, Elditest

1500 series mini data loggers Complete range of mini data loggers for all temperature, humidity, and industrial parameter monitoring applications. Logs saved for more than 2 years (memory capacity: 21,600 measurements or 43,300 for LOG 1550 K1 model). Possibility of recovering data without interrupting recording. Programming of recording start and end date. Remote controlled start/stop. Monitoring of industrial process parameters. 4-20 mA and 0-10 V loop monitoring. PC-based real time acquisition. Infrared interface. Windows-based software. Common characteristics: SEFRAM LOG 1501P Number of channels: 1 Measurement type: Internal temperature Range of measurement: -40°C → +85°C Accuracy: ±1 °C PDA compatibility: yes SEFRAM LOG 1510-K Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -50 °C to +150 °C (Te) Accuracy: ±1 °C (Ti) - ±0.5 °C + 1 °C (Te) SEFRAM LOG 1510-K1 Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -100 °C to +1200 °C (Te) Accuracy: ±1 °C (Ti) - ±2 °C + 1 °C (Te) SEFRAM LOG 1520P Number of channels: 2 Measurement type: Internal temperature, humidity Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 5% to 95% (HR) Accuracy: ±3% PDA compatibility: yes SEFRAM LOG 1520-K Number of channels: 3 Measurement type: -40 °C to 85 °C (Ti) -50 °C to 150 °C (Te) Accuracy: ±1 °C (Ti) ±0.5 °C (Te) Range of measurement: 5% to 95% (HR) Accuracy: ±3% Common characteristics: SEFRAM LOG 1525 Number of channels: 2 Measurement type: Internal temperature, DC voltage Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 2.5 V / 10 V / 25 V (DC.) Accuracy: ±0.1% SEFRAM LOG 1550-K1 Number of channels: 5 Memory holds 43,300 measur...
New items
SEFRAM LOG 1550-K1, Elditest

SEFRAM LOG 1550-K1, Elditest

1500 series mini data loggers Complete range of mini data loggers for all temperature, humidity, and industrial parameter monitoring applications. Logs saved for more than 2 years (memory capacity: 21,600 measurements or 43,300 for LOG 1550 K1 model). Possibility of recovering data without interrupting recording. Programming of recording start and end date. Remote controlled start/stop. Monitoring of industrial process parameters. 4-20 mA and 0-10 V loop monitoring. PC-based real time acquisition. Infrared interface. Windows-based software. Common characteristics: SEFRAM LOG 1501P Number of channels: 1 Measurement type: Internal temperature Range of measurement: -40°C → +85°C Accuracy: ±1 °C PDA compatibility: yes SEFRAM LOG 1510-K Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -50 °C to +150 °C (Te) Accuracy: ±1 °C (Ti) - ±0.5 °C + 1 °C (Te) SEFRAM LOG 1510-K1 Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -100 °C to +1200 °C (Te) Accuracy: ±1 °C (Ti) - ±2 °C + 1 °C (Te) SEFRAM LOG 1520P Number of channels: 2 Measurement type: Internal temperature, humidity Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 5% to 95% (HR) Accuracy: ±3% PDA compatibility: yes SEFRAM LOG 1520-K Number of channels: 3 Measurement type: -40 °C to 85 °C (Ti) -50 °C to 150 °C (Te) Accuracy: ±1 °C (Ti) ±0.5 °C (Te) Range of measurement: 5% to 95% (HR) Accuracy: ±3% Common characteristics: SEFRAM LOG 1525 Number of channels: 2 Measurement type: Internal temperature, DC voltage Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 2.5 V / 10 V / 25 V (DC.) Accuracy: ±0.1% SEFRAM LOG 1550-K1 Number of channels: 5 Memory holds 43,300 measur...
New items
1520P1, Elditest

1520P1, Elditest

1500 series mini data loggers Complete range of mini data loggers for all temperature, humidity, and industrial parameter monitoring applications. Logs saved for more than 2 years (memory capacity: 21,600 measurements or 43,300 for LOG 1550 K1 model). Possibility of recovering data without interrupting recording. Programming of recording start and end date. Remote controlled start/stop. Monitoring of industrial process parameters. 4-20 mA and 0-10 V loop monitoring. PC-based real time acquisition. Infrared interface. Windows-based software. Common characteristics: SEFRAM LOG 1501P Number of channels: 1 Measurement type: Internal temperature Range of measurement: -40°C → +85°C Accuracy: ±1 °C PDA compatibility: yes SEFRAM LOG 1510-K Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -50 °C to +150 °C (Te) Accuracy: ±1 °C (Ti) - ±0.5 °C + 1 °C (Te) SEFRAM LOG 1510-K1 Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -100 °C to +1200 °C (Te) Accuracy: ±1 °C (Ti) - ±2 °C + 1 °C (Te) SEFRAM LOG 1520P Number of channels: 2 Measurement type: Internal temperature, humidity Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 5% to 95% (HR) Accuracy: ±3% PDA compatibility: yes SEFRAM LOG 1520-K Number of channels: 3 Measurement type: -40 °C to 85 °C (Ti) -50 °C to 150 °C (Te) Accuracy: ±1 °C (Ti) ±0.5 °C (Te) Range of measurement: 5% to 95% (HR) Accuracy: ±3% Common characteristics: SEFRAM LOG 1525 Number of channels: 2 Measurement type: Internal temperature, DC voltage Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 2.5 V / 10 V / 25 V (DC.) Accuracy: ±0.1% SEFRAM LOG 1550-K1 Number of channels: 5 Memory holds 43,300 measur...
New items
GE 3421, Elditest

GE 3421, Elditest

Elditest GE 3421 High Voltage 4kV x100, Oscilloscope Probes Compact probe for oscilloscopes Input Voltage Max. 4kV ac or dc Attenuation x 100 Cable Length 1.2m Voltage Category IEC1010-2-031 4kV Cat I or 2kV Cat II Bandwidth d.c. - 100MHz Rise/Fall Time 3.5ns Compensation Range 10-30pF Input Capacitance 20pF Input Impedance 50MΩ Note This product is for use with instruments with a permanent earth connection Supplied with 1 compensation trimming tool and sprung hook grabber. Note Probe (4pf) adjusted at factory to match an oscilloscope with an input capacitance of 20pf at 100MHz
New items
SI 693, Elditest

SI 693, Elditest

1500 series mini data loggers Complete range of mini data loggers for all temperature, humidity, and industrial parameter monitoring applications. Logs saved for more than 2 years (memory capacity: 21,600 measurements or 43,300 for LOG 1550 K1 model). Possibility of recovering data without interrupting recording. Programming of recording start and end date. Remote controlled start/stop. Monitoring of industrial process parameters. 4-20 mA and 0-10 V loop monitoring. PC-based real time acquisition. Infrared interface. Windows-based software. Common characteristics: SEFRAM LOG 1501P Number of channels: 1 Measurement type: Internal temperature Range of measurement: -40°C → +85°C Accuracy: ±1 °C PDA compatibility: yes SEFRAM LOG 1510-K Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -50 °C to +150 °C (Te) Accuracy: ±1 °C (Ti) - ±0.5 °C + 1 °C (Te) SEFRAM LOG 1510-K1 Number of channels: 2 Measurement type: Internal and external temperature Range of measurement: -40 °C to +85 °C (Ti), -100 °C to +1200 °C (Te) Accuracy: ±1 °C (Ti) - ±2 °C + 1 °C (Te) SEFRAM LOG 1520P Number of channels: 2 Measurement type: Internal temperature, humidity Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 5% to 95% (HR) Accuracy: ±3% PDA compatibility: yes SEFRAM LOG 1520-K Number of channels: 3 Measurement type: -40 °C to 85 °C (Ti) -50 °C to 150 °C (Te) Accuracy: ±1 °C (Ti) ±0.5 °C (Te) Range of measurement: 5% to 95% (HR) Accuracy: ±3% Common characteristics: SEFRAM LOG 1525 Number of channels: 2 Measurement type: Internal temperature, DC voltage Range of measurement: -40 °C to +85 °C (Ti) Accuracy: ±1 °C Range of measurement: 2.5 V / 10 V / 25 V (DC.) Accuracy: ±0.1% SEFRAM LOG 1550-K1 Number of channels: 5 Memory holds 43,300 measur...
New items
EMK400, Elditest

EMK400, Elditest

Kelvin test cables The Kelvin test cable permits measurement of 4 lines per milliohmmeter or RLC bridge. The connecting clips ensure excellent contact with the component to be measured. Contacts: gold plated Outputs: 4 x 4 mm jacks code 163-9003 4 x BNC input plugs code 366-5981 Cables: RG 174/U, length 650 mm Insulation: 250 V RMS / 5 A
New items
GE-2521, Elditest

GE-2521, Elditest

Elditest Compact Ergonomic Oscilloscope Probes Compact, ergonomically designed probes (non-modular) for oscilloscopes Integral compensation trimmer Cable length 1.2m Termination 50Ω BNC Voltage category IEC1010-2-031 300V Cat 1 Test voltage 1150V For accessories kit ( 1 screw driver, 1 BNC adaptor, 1 ground lead, 1 test clip, 1 needle ) see 207-4429 Model GE1501 GE2501 GE1511 GE1521 GE2511 GE2521 Attenuation x1 x1 x10 x1/x10 x10 x1/x10 Bandwidth 30MHz 55MHz 150MHz 150MHz 250MHz 250MHz Rise/Fall Time 11ns 6.4ns 2.3ns 2.3; 20ns 1.4ns 7.7; 1.4ns Compensation Range 7777pF 7777pF 10-30pF 10-30pF 10-30pF 10-30pF Input Capacitance 45pF 45pF 12pF 45; 12pF 12pF 45; 1245pF Input Impedance 1MΩ 1MΩ 10MΩ 1(x1); 10(x10)MΩ 10MΩ 1(x1); 10(x10)MΩ Note This product is for use with instruments with a permanent earth connection Supplied with 1 replacement tip 1 coaxial adaptor 1 spring hook grabber 1 compensation trimming tool 1 earth lead with crocodile clip Passive Oscilloscope Probes Note All the products in this range are supplied for use with instruments with a permanent earth connection.