Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

5.0 / 5

Reviews 1 Outstanding
Cropico Profile

Cropico is a leading manufacturer of electrical and test equipment, founded in 1982. The company has been a leading supplier of electrical safety analysers, testers, and kits to global customers for over 40 years, with its main offices in the UK and USA. Cropico’s electronic component testing and decade boxes are extensively used in various markets with high appreciation. The company also provides calibration, services, product training, and repairs for valued customers. Cropico’s OEM products, portable appliance testers, and safety testers & accessories are widely used in medical, industrial, and commercial markets for user-desired applications.

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(100%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Peter Sellers
18 Jan, 2023

Company in full transparency! Customer service is the best! The products are of the highest quality and the design is impeccable!

Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Cropico




New Items
New items
DO4002, Cropico

DO4002, Cropico

Handheld 4000 Series True 4 terminal measurement to eliminate lead resistance errors 4000 count 15mm LCD screen with LED indicators Auto/manual range selection Enhanced accuracy with auto-average for forward and reverse measurement currents to eliminate error due to thermal emf True Zero button Auto power-off saves battery life Protected to IP54 Supplied with: 5 x AA alkaline batteries, measuring leads with Kelvin clips and instructions. DO4002 specification Range Resolution Accuracy Typical Current 400Ω 100Ω ±(0.05% Rdg +0.02 % FS) 1mA 40Ω 10mΩ ±(0.05% Rdg +0.02 % FS) 10mA 4Ω 1mΩ ±(0.05% Rdg +0.02 % FS) 100mA 400mΩ 100μΩ ±(0.05% Rdg +0.03 % FS) 1A 40mΩ 10μΩ ±(0.05% Rdg +0.05 % FS) 1A 4mΩ 1μΩ ±(0.05% Rdg +0.1 % FS) 1A DO4000 specification Range Resolution Accuracy Typical Current 4kΩ 1Ω ±(0.05% Rdg +0.02 % FS) 100μA 400Ω 100mΩ ±(0.05% Rdg +0.02 % FS) 1mA 40Ω 10mΩ ±(0.05% Rdg +0.02 % FS) 10mA 4Ω 1mΩ ±(0.05% Rdg +0.03 % FS) 10mA 400mΩ 100μΩ ±(0.05% Rdg +0.05 % FS) 10 mA 40mΩ 10μΩ ±(0.05% Rdg +0.1 % FS) 100mA
New items
RM6-N, Cropico

RM6-N, Cropico

Calibration/ Substitution, 6 Decade Euro Style Resistance Box Compact, durable case manufactured from high impact polystyrene, with metal film resistors and silver plated brass contact switches. Particularly suitable for use in electrical and electronic industrial laboratories. Required resistance selected by the rotary switches.
New items
RBB6-B, Cropico

RBB6-B, Cropico

Calibration/Substitution, High Accuracy 6 Decade Resistance Box Compact, durable case of encapsulated moulded epoxy Constructed using low temperature coefficient resistor wire and gold plated contact switches Particularly suitable for use in electrical and electronic industrial laboratories Required resistance selected by the 6 rotary switches The -B and -C models are suitable for pt100 simulation
New items
RM6, Cropico

RM6, Cropico

Calibration/Substitution, 6 Decade Rotary Resistance Box A compact and ruggedly constructed 6 decade resistance box. Ideal for general-purpose resistance simulation or substitution in industrial or educational environments. The product has been designed for easy customer servicing, all of the resistors being replaceable by standard metal film resistors. Refer to the Resistors/Potentiometers section.
New items
RM6-N2, Cropico

RM6-N2, Cropico

Calibration/Substitution, Compact 6 Decade Resistance Box Compact, durable case manufactured from high impact polystyrene Metal film resistors and silver plated brass contact switches Particularly suitable for use in electrical and electronic industrial laboratories Required resistance selected by the 6 rotary switches An additional 1KΩ resistor is available at the terminals, enabling the user to make a simple divider
New items
RBB6-C, Cropico

RBB6-C, Cropico

Calibration/Substitution, High Accuracy 6 Decade Resistance Box Compact, durable case of encapsulated moulded epoxy Constructed using low temperature coefficient resistor wire and gold plated contact switches Particularly suitable for use in electrical and electronic industrial laboratories Required resistance selected by the 6 rotary switches The -B and -C models are suitable for pt100 simulation
New items
RBB5-B, Cropico

RBB5-B, Cropico

Calibration/Substitution, High Accuracy 5 Decade Resistance Box Compact, durable case of encapsulated moulded epoxy Constructed using low temperature coefficient resistor wire and gold plated contact switches Particularly suitable for use in electrical and electronic industrial laboratories Required resistance selected by the 5 rotary switches The -B model is suitable for pt100 simulation
New items
RM6-N3, Cropico

RM6-N3, Cropico

Calibration/Substitution, Compact 6 Decade Resistance Box Compact, durable case manufactured from high impact polystyrene Metal film resistors and silver plated brass contact switches Particularly suitable for use in electrical and electronic industrial laboratories Required resistance selected by the 6 rotary switches An additional 1KΩ resistor is available at the terminals, enabling the user to make a simple divider
New items
DO4000, Cropico

DO4000, Cropico

Handheld 4000 Series True 4 terminal measurement to eliminate lead resistance errors 4000 count 15mm LCD screen with LED indicators Auto/manual range selection Enhanced accuracy with auto-average for forward and reverse measurement currents to eliminate error due to thermal emf True Zero button Auto power-off saves battery life Protected to IP54 Supplied with: 5 x AA alkaline batteries, measuring leads with Kelvin clips and instructions. DO4002 specification Range Resolution Accuracy Typical Current 400Ω 100Ω ±(0.05% Rdg +0.02 % FS) 1mA 40Ω 10mΩ ±(0.05% Rdg +0.02 % FS) 10mA 4Ω 1mΩ ±(0.05% Rdg +0.02 % FS) 100mA 400mΩ 100μΩ ±(0.05% Rdg +0.03 % FS) 1A 40mΩ 10μΩ ±(0.05% Rdg +0.05 % FS) 1A 4mΩ 1μΩ ±(0.05% Rdg +0.1 % FS) 1A DO4000 specification Range Resolution Accuracy Typical Current 4kΩ 1Ω ±(0.05% Rdg +0.02 % FS) 100μA 400Ω 100mΩ ±(0.05% Rdg +0.02 % FS) 1mA 40Ω 10mΩ ±(0.05% Rdg +0.02 % FS) 10mA 4Ω 1mΩ ±(0.05% Rdg +0.03 % FS) 10mA 400mΩ 100μΩ ±(0.05% Rdg +0.05 % FS) 10 mA 40mΩ 10μΩ ±(0.05% Rdg +0.1 % FS) 100mA
New items
RBB6-F, Cropico

RBB6-F, Cropico

Calibration/Substitution, High Accuracy 6 Decade Resistance Box Compact, durable case of encapsulated moulded epoxy Constructed using low temperature coefficient resistor wire and gold plated contact switches Particularly suitable for use in electrical and electronic industrial laboratories Required resistance selected by the 6 rotary switches The -B and -C models are suitable for pt100 simulation
New items
DO7, Cropico

DO7, Cropico

Rugged Digital Micro ohmmeters Wide measurement range of 1mΩ to 20kΩ Four terminal measurement using Kelvin lead set Battery operation with built-in charger 1 to 20 hours use depending on current setting RS232 connection for printer or computer (also USB on Plus model) Rugged ABS case with carry handle Model DO7 343 x 327 x 152 mm Range Resolution Test Current 60 Ω 10 mΩ 1mA 6 Ω 1 mΩ 10mA 600 mΩ 100 μΩ 100mA 60 mΩ 10 μΩ 1A 6 mΩ 1 μΩ 10A 600 μΩ 0.1 μΩ 10A Accuracy ± 0.15% reading ± 0.05% range Temp coefficient ± 40ppm Power Internal Ni-MH batteries giving from 1 to 20 hours operation. Built-in mains charger 230V or 115V nominal Safety Complies with IEC 1010-1 Model DO7Plus 358 X 269 X 155 mm Range Resolution Test Current 6 kΩ 100 mΩ 100 μA 600 Ω 10 mΩ 100 μA 60 Ω 1 mΩ 1mA 6 Ω 100 μΩ 10mA 600 mΩ 10 μΩ 100mA 60 mΩ 1 μΩ 1A 6 mΩ 0.1 μΩ 10A Accuracy ± 0.05% reading ± 0.01% range Power Internal Ni-MH batteries giving from 1 to 20 hours operation. Built-in mains charger 90 to 253 Vac - 47 to 63 Hz Safety Conforms to EN61010-1 : 2001 600V Cat 3
New items
RBC5-A, Cropico

RBC5-A, Cropico

High Dissipation 5 Decade Resistance Box For applications requiring a dissipation of up to 5W per resistor coupled with a reasonable degree of accuracy. Housed in a light alloy case with ventilation slots. Particularly suitable for arduous use, especially in industrial applications. Resistance per step in ohms 1000 100 10 1 0.1 Maximum current in amps 0.07 0.22 0.7 2.2 7 Accuracy of adjustment ±5% ±5% ±5% ±10% ±10%