Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

We hope you are enjoying our new upgraded website. Bringing you faster search results and a greater variety of products. Please click here to share your comments/experience.

Showing Results For: Electrical test equipment

Electrical Test Equipment

Popular Items
Popular items
ISO-TECH IVP-1 Non Contact Voltage Detector With RS Calibration, 100V ac to 1000V ac

ISO-TECH IVP-1 Non Contact Voltage Detector With RS Calibration, 100V ac to 1000V ac

IVP-1 Volt Pen Non Contact Voltage Indicator The IVP-1 Volt Stick is a pen style non contact AC voltage indicator for safely checking the presence of an AC voltage in cables, wall sockets, fuses junction boxes etc. No current flow is needed for correct operation. Tip glows red and the audible sounder activates when a voltage is detected. Locates breaks in cables Detects blown fuses inside plugs or fuse holders Distinguish between live and neutral wires in both single and three-phase supplies Identifies voltage-carrying cables in junction boxes Identifies faulty in-line switches Locates faulty lamps in series connections Complies with IEC 61010-1 CAT IV 1000V Sensitivity (50Hz) 240 Vac Power supply 2 x AAA batteries Operating temp. 0 °C → +40 °C Dimensions & weight 152 x 22 x18 mm, 40 gram (incl. batteries) Humidity Note Periodically wipe the VOLT PEN with a dry cloth, do not use abrasive or solvents Caution Will NOT detect cables behind buried plaster, buried trunking etc. and will not detect output from safety isolation transformers with earthed secondary centre tap. The unit should be checked for correct operation using a known voltage before use. Supplied with 2x AAA batteries & instructions

Product Detail
Popular items
Chauvin Arnoux PAC10 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600 V, CAT IV 300 V With RS Calibration

Chauvin Arnoux PAC10 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600 V, CAT IV 300 V With RS Calibration

10 Series PAC Current Probes Hall effect current probes allowing measurement of direct or alternating currents, without disturbing or breaking the circuit. Multimeter output (PAC 10 and 11). Voltage output. Zero adjustment using a thumb wheel (PAC 10) or automatically by simply pressing a push button (PAC 11). "ON" indicator shows that battery is working satisfactorily and "OL" warns of low battery. Cancellable auto-power off. Standard: IEC 1010-1 Cat. III, deg. 2 Measuring range A AC: 0.5 → 400 A AC Measuring range (A dc): 0.5 → 600 A DC Sensitivity: 10 mV/A (PAC 11) and 1 mV/A (PAC 10) Bandwidth: 0 Hz → 5 kHz Max. diameter of conductor: Ø 30 mm, bar 50 x 10 mm Lead length: 1.5 m Supply: 1 9 V PP3-type battery supplied Dimensions (mm): 224 x 97 x 44 Weight: 440 g

Product Detail
Popular items
Amprobe AC68C Clamp Meter, Max Current 600A ac, 600A dc CAT II 600 V, CAT III 300 V With UKAS Calibration

Amprobe AC68C Clamp Meter, Max Current 600A ac, 600A dc CAT II 600 V, CAT III 300 V With UKAS Calibration

Amprobe AC68C Clamp Multimeter Automatic and manual measuring range selection Measurement of AC and DC voltages Frequency and top value readings Actual value measurement (TRMS) Hold function Acoustic continuity test Measuring resistance Measurement Range Accuracy Current AC 0.1 A → 600 A ±2% + 5 digit Current DC 0.1 A → 600 A ±2% + 5 digit Voltage AC 0.1 V → 600 V ±1.2% + 10 digit Voltage DC 0.1 V → 600 V ± 0.75% + 2 digits Resistance 1 Ω → 4 kΩ ± 1% + 5 digits Frequency 1 Hz → 20 kHz General data Display 3999 digits Clamp opening 40 mm Power supply 9 V block Dimensions 76 x 228 x 39 mm Weight approx. 465 g Standards CAT III 600 V Supplied with Current clamp, measuring leads, battery, carry case, instructions

Product Detail
Popular items
Kewtech Corporation Lightmate BC Mains Socket Tester Adapter, For Use With Light Fitting

Kewtech Corporation Lightmate BC Mains Socket Tester Adapter, For Use With Light Fitting

LightMate Lamp Holder Testing Adaptors An essential testing accessory to facilitate fast and safe testing for loop impedance, and R1 & R2 testing of lighting circuits Reduces the need to hold test probes in place Positive connection of test leads to lamp holders EN61010-1 CAT II 300V

Product Detail
Popular items
Chauvin Arnoux PAC22 Clamp Meter, Max Current 1kA ac, 1.4kA dc CAT III 600 V, CAT IV 300 V

Chauvin Arnoux PAC22 Clamp Meter, Max Current 1kA ac, 1.4kA dc CAT III 600 V, CAT IV 300 V

20 Series PAC Current Probes Hall effect current probes allowing measurement of direct or alternating currents, without disturbing or breaking the circuit. Multimeter (PAC 20 and 21) or oscilloscope (PAC 22) output. Voltage output. Zero adjustment by means of a thumb wheel (PAC 20) or automatically by simply pressing a pushbutton (PAC 21 and 22). "ON" indicator shows that battery is working satisfactorily and "OL" warns of low battery. Auto-power off, can be disabled, on PAC 21 and PAC 22. Standard: IEC 1010-1 Cat. III, deg. 2

Product Detail
Popular items
Metrix MX670 Clamp Meter, Max Current 1kA ac CAT III 1000 V, CAT IV 600 V

Metrix MX670 Clamp Meter, Max Current 1kA ac CAT III 1000 V, CAT IV 600 V

MX 670 and MX 675 Clip-On Multimeters TRMS AC or AC / DC clip-on multimeters, 10000-count dual display, 600 V CAT IV. The dual display of these clamps enables voltage and current measurements to be viewed simultaneously. Functions: HOLD, AUTO-HOLD, MIN, MAX, Peak, Ø Zero. For measuring current, voltage, frequency, resistance / continuity and temperature (via the K thermocouple sensor covering a range from -40 °C → +1200 °C). The MX 670, AC TRMS can be used to measure currents up to1000 A AC. The MX 675, AC / DC TRMS can be used to measure continuous currents up to 1400 A DC and 1000 A AC. MX 670 MX 675 Clamping Ø: 42 mm 40 mm DC Measurement - 0.05 A → 1400 A Dimensions / Weight 272 x 80 x 43 mm / 480 g 257 x 80 x 43 mm / 440 g Measurement type: RMS AC current measurement: 0.05 A → 1000 A DC current measurement: 0.2 V → 1400 V AC voltage measurement 0.5 V → 1000 V Resistance 0.3 Ω → 9999 Ω Audible continuity Yes Current / voltage frequency 0.2 Hz → 9999 Hz Temperature -40 °C → +999.5 °C +1000 °C → +1200 °C Display 10000-count dual display with blue backlighting Standards IEC 61010; CAT III 1000 V; CAT IV 600 V Supplied with 1 x 9 V alkaline battery, 1 operating manual in 5 languages, 1 soft carry bag, 1 set of leads with test probes (Ø 4 mm), 1 K thermocouple sensor

Product Detail
Popular items
Chauvin Arnoux CA773 Voltage Indicator with RCD Trip Test Continuity Check CAT IV 1000 V

Chauvin Arnoux CA773 Voltage Indicator with RCD Trip Test Continuity Check CAT IV 1000 V

C.A 773 IP2X Voltage Absence Tester (VAT) CAT IV 1000V The C.A 773 IP2X Voltage Tester is a VAT with digital display and LEDs for voltages up to 1000 VAC/1400 VDC with with audible extended continuity and phase rotation testing. The Voltage Tester also offers trip testing of RCDs rated 30 mA (or less), as well as lighting of the test probe/point of measurement and digital display of the resistance and voltage. 1000 VAC / 1400 VDC Single-pole phase test Continuity andresistance test with audible and visual indication Two-pole phase sequence test with 2-wire method RCD trip testing and Detection of stray voltages Lighting of point of measurement. CAT IV 1000V IP65 Standards IEC 61243-3:2009, EN 61243-3:2010, IEC 61010 1,000 V CAT IV Supplied with Voltage absence tester, User's guide in 5 languages, 2 x 1.5 V LR03/AAA batteries, 1 set of IP2X removable test probes Ø 4 mm and 1 Velcro strap.

Product Detail
Popular items
RS Pro Magnetic Field Detector 0.3mT 1000V ac

RS Pro Magnetic Field Detector 0.3mT 1000V ac

Intrinsically-Safe Magnetic Field Indicator Intrinsically-Safe Magnetic Field Indicator with high performance. Approved for use in hazardous areas The tip of the intrinsically safe magnet stick lights up in the presence of a magnetic field Responds to all kinds of magnetic field from alternating current and direct current and permanent strong magnets Supplied with 2 x AAA alkaline batteries (stock No. 591-657 ) and integral test magnet.

Product Detail
Popular items
RS PRO ICM133R Clamp Meter, Max Current 1kA ac CAT III 600 V With RS Calibration

RS PRO ICM133R Clamp Meter, Max Current 1kA ac CAT III 600 V With RS Calibration

ICM133R 1000A ac,True-rms reading 1000A ac current measurement 750Vac / 1000Vdc voltage measurement Large 51mm dia. conductor jaw capacity 4000 count backlit digital display with analogue bargraph True RMS reading on AC mode Resistance & continuity beeper Display Hold & Min Max Function 10ms Peak Hold on ac A & ac V Frequency Counter Auto Power Off (30 minutes) Separate battery compartment 600V circuit protection Complies with EN61010 CAT. III 600V Safety Standard for industrial applications Rugged construction with flame retardant, high impact plastic ac voltage Ranges 400V & 750V Resolution 0.1V & 1V Basic Accuracy ±(1.0% rdg+ 5d) 50 to 500Hz dc voltage Ranges 400V & 1000V Resolution 0.1V & 1V Basic Accuracy ±(0.7% rdg+ 2d) ac current Ranges 400A & 1000A Resolution 0.1A & 1A Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Resistance Range 400Ω Resolution 0.1Ω Basic Accuracy ±(1.0% rdg+ 3d) Frequency counter Ranges 4kHz & 10kHz Resolution 1Hz & 10Hz Basic Accuracy ±(0.1% + 2d) @5V rms max Size (WxHxD) and Weight 90 x 275 x 51mm, 420g Supplied with Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.

Product Detail
Popular items
Martindale MARVT25/PD Voltage Indicator & Proving Unit Kit

Martindale MARVT25/PD Voltage Indicator & Proving Unit Kit

Martindale Voltage Indicator and Proving Unit Kit MARVT25/PD Safe isolation procedures state that voltage indicators should be proved against a known source both before and after use. Martindale kit MARVT25/PD contains the VT25 voltage indicator and PD690 proving unit. These instruments are housed in a TC55 carry case with a neck strap, making it easy to carry and use the equipment on site. The VT25 is a two pole LED voltage indicator for use on AC or DC systems, displaying voltages from 12 V to 690 V. Additional functions of this model include audible and optical continuity, phase rotation and a single pole phase test. Safety features include a built-in torch and two layers of insulation on the cable. The inner layer insulation is a contrasting colour to the outer, making it easy to see if there has been any damage to the cable. The PD690 proving unit with this kit will light up all the LEDs on the indicator, enabling users to ensure the indicator is working correctly. The proving unit also features a low battery indicator. Standards BS EN61243-3:2010 CAT IV 600V, CAT III 1000V Supplied with Carry case, neck strap, AAA 1.5 V batteries (x2), instructions Martindale Lock-Off Kits, Voltage Indicators and Proving Units

Product Detail
Popular items
Weidmuller COMBI CHECK 1.3 Voltage Indicator Continuity Check

Weidmuller COMBI CHECK 1.3 Voltage Indicator Continuity Check

Combi Check Voltage Testers The main function of the voltage tester is to establish if voltage is present and display this value clearly. LEDs display the following voltages: 6,12, 24, 50, 120, 230, 400, 690 V High peak voltage strength 6 to 690 V measurement range Continuity testing Runs on 1 x AAA battery (supplied) Approvals VDE-Norm 0682, Section 401 Weidmuller Two Pole Voltage Testers

Product Detail
Popular items
Megger TDR900 TDR Cable Fault Locator, 3.7km

Megger TDR900 TDR Cable Fault Locator, 3.7km

Megger TDR 900 Handheld Time Domain Reflectometer/Cable LEngth Meter The Megger TDR900 is an advanced instrument capable of measuring cable lengths and finding distance to an open or a short using Time Domain Reflectometry. It offers exceptional features and a range capability normally associated with far more expensive instruments. The measurement range spans from 15 feet (5 m) to 10,000 feet (3 km) with a minimum resolution of 20 inches (50 cm). The TDR900 can be used for any cable consisting of at east two insulated metallic elements, one of which may be the sheath or shield of the cable. The Meter has automatic internal matching networks to allow testing of 25, 50, 75, 100, 125, or 150 cables. (These correspond to power, telephony, CATV, and LAN cables). Typical applications: Street lighting cable runs Outside broadcasting: check temporary cable installations Studio broadcasting: trailing camera cables, etc. Cable drops from aerials and antenna Stocktaking: measure cable lengths in stock, etc. CE-Certificated Accurate to 20 inches (50 cm) throughout the entire range Extra-large backlit (ICON type 7 segment) LCD Automatic output impedance control, auto-range, autozero, and auto-sensitivity allows for closely matching to a wide range of cables under test. Only V.O.P (velocity of propagation) settings required Displays cable length if the cable�s V.O.P (velocity of propagation) is known or displays V.O.P (velocity of propagation) if a cable�s length is known 20 internal memory locations store up to 20 custom cable V.O.P settings Internal library of 39 standard cables allow for quick and easy measurements for industry standard cable types Tone Generator (oscillating 910 to 1100 Hz; 5 V peak to peak) for cable identification and tracing Line Voltage Detection: Displays �OUCH� message and stops operation if line voltage exceeds 6.5 V Safety Protection (up to 250 V RMS) Supplied with ...

Product Detail
Next
New Added Items
New items
RS Pro Magnetic Field Detector 0.3mT 1000V ac

RS Pro Magnetic Field Detector 0.3mT 1000V ac

Intrinsically-Safe Magnetic Field Indicator Intrinsically-Safe Magnetic Field Indicator with high performance. Approved for use in hazardous areas The tip of the intrinsically safe magnet stick lights up in the presence of a magnetic field Responds to all kinds of magnetic field from alternating current and direct current and permanent strong magnets Supplied with 2 x AAA alkaline batteries (stock No. 591-657 ) and integral test magnet.

Product Detail
New items
Kewtech Corporation Lightmate BC Mains Socket Tester Adapter, For Use With Light Fitting

Kewtech Corporation Lightmate BC Mains Socket Tester Adapter, For Use With Light Fitting

LightMate Lamp Holder Testing Adaptors An essential testing accessory to facilitate fast and safe testing for loop impedance, and R1 & R2 testing of lighting circuits Reduces the need to hold test probes in place Positive connection of test leads to lamp holders EN61010-1 CAT II 300V

Product Detail
New items
Amprobe AC68C Clamp Meter, Max Current 600A ac, 600A dc CAT II 600 V, CAT III 300 V With UKAS Calibration

Amprobe AC68C Clamp Meter, Max Current 600A ac, 600A dc CAT II 600 V, CAT III 300 V With UKAS Calibration

Amprobe AC68C Clamp Multimeter Automatic and manual measuring range selection Measurement of AC and DC voltages Frequency and top value readings Actual value measurement (TRMS) Hold function Acoustic continuity test Measuring resistance Measurement Range Accuracy Current AC 0.1 A → 600 A ±2% + 5 digit Current DC 0.1 A → 600 A ±2% + 5 digit Voltage AC 0.1 V → 600 V ±1.2% + 10 digit Voltage DC 0.1 V → 600 V ± 0.75% + 2 digits Resistance 1 Ω → 4 kΩ ± 1% + 5 digits Frequency 1 Hz → 20 kHz General data Display 3999 digits Clamp opening 40 mm Power supply 9 V block Dimensions 76 x 228 x 39 mm Weight approx. 465 g Standards CAT III 600 V Supplied with Current clamp, measuring leads, battery, carry case, instructions

Product Detail
New items
Chauvin Arnoux PAC10 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600 V, CAT IV 300 V With RS Calibration

Chauvin Arnoux PAC10 Clamp Meter, Max Current 400A ac, 400A dc CAT III 600 V, CAT IV 300 V With RS Calibration

10 Series PAC Current Probes Hall effect current probes allowing measurement of direct or alternating currents, without disturbing or breaking the circuit. Multimeter output (PAC 10 and 11). Voltage output. Zero adjustment using a thumb wheel (PAC 10) or automatically by simply pressing a push button (PAC 11). "ON" indicator shows that battery is working satisfactorily and "OL" warns of low battery. Cancellable auto-power off. Standard: IEC 1010-1 Cat. III, deg. 2 Measuring range A AC: 0.5 → 400 A AC Measuring range (A dc): 0.5 → 600 A DC Sensitivity: 10 mV/A (PAC 11) and 1 mV/A (PAC 10) Bandwidth: 0 Hz → 5 kHz Max. diameter of conductor: Ø 30 mm, bar 50 x 10 mm Lead length: 1.5 m Supply: 1 9 V PP3-type battery supplied Dimensions (mm): 224 x 97 x 44 Weight: 440 g

Product Detail
New items
Metrix MX670 Clamp Meter, Max Current 1kA ac CAT III 1000 V, CAT IV 600 V

Metrix MX670 Clamp Meter, Max Current 1kA ac CAT III 1000 V, CAT IV 600 V

MX 670 and MX 675 Clip-On Multimeters TRMS AC or AC / DC clip-on multimeters, 10000-count dual display, 600 V CAT IV. The dual display of these clamps enables voltage and current measurements to be viewed simultaneously. Functions: HOLD, AUTO-HOLD, MIN, MAX, Peak, Ø Zero. For measuring current, voltage, frequency, resistance / continuity and temperature (via the K thermocouple sensor covering a range from -40 °C → +1200 °C). The MX 670, AC TRMS can be used to measure currents up to1000 A AC. The MX 675, AC / DC TRMS can be used to measure continuous currents up to 1400 A DC and 1000 A AC. MX 670 MX 675 Clamping Ø: 42 mm 40 mm DC Measurement - 0.05 A → 1400 A Dimensions / Weight 272 x 80 x 43 mm / 480 g 257 x 80 x 43 mm / 440 g Measurement type: RMS AC current measurement: 0.05 A → 1000 A DC current measurement: 0.2 V → 1400 V AC voltage measurement 0.5 V → 1000 V Resistance 0.3 Ω → 9999 Ω Audible continuity Yes Current / voltage frequency 0.2 Hz → 9999 Hz Temperature -40 °C → +999.5 °C +1000 °C → +1200 °C Display 10000-count dual display with blue backlighting Standards IEC 61010; CAT III 1000 V; CAT IV 600 V Supplied with 1 x 9 V alkaline battery, 1 operating manual in 5 languages, 1 soft carry bag, 1 set of leads with test probes (Ø 4 mm), 1 K thermocouple sensor

Product Detail
New items
ISO-TECH IVP-1 Non Contact Voltage Detector With RS Calibration, 100V ac to 1000V ac

ISO-TECH IVP-1 Non Contact Voltage Detector With RS Calibration, 100V ac to 1000V ac

IVP-1 Volt Pen Non Contact Voltage Indicator The IVP-1 Volt Stick is a pen style non contact AC voltage indicator for safely checking the presence of an AC voltage in cables, wall sockets, fuses junction boxes etc. No current flow is needed for correct operation. Tip glows red and the audible sounder activates when a voltage is detected. Locates breaks in cables Detects blown fuses inside plugs or fuse holders Distinguish between live and neutral wires in both single and three-phase supplies Identifies voltage-carrying cables in junction boxes Identifies faulty in-line switches Locates faulty lamps in series connections Complies with IEC 61010-1 CAT IV 1000V Sensitivity (50Hz) 240 Vac Power supply 2 x AAA batteries Operating temp. 0 °C → +40 °C Dimensions & weight 152 x 22 x18 mm, 40 gram (incl. batteries) Humidity Note Periodically wipe the VOLT PEN with a dry cloth, do not use abrasive or solvents Caution Will NOT detect cables behind buried plaster, buried trunking etc. and will not detect output from safety isolation transformers with earthed secondary centre tap. The unit should be checked for correct operation using a known voltage before use. Supplied with 2x AAA batteries & instructions

Product Detail
New items
Chauvin Arnoux PAC22 Clamp Meter, Max Current 1kA ac, 1.4kA dc CAT III 600 V, CAT IV 300 V

Chauvin Arnoux PAC22 Clamp Meter, Max Current 1kA ac, 1.4kA dc CAT III 600 V, CAT IV 300 V

20 Series PAC Current Probes Hall effect current probes allowing measurement of direct or alternating currents, without disturbing or breaking the circuit. Multimeter (PAC 20 and 21) or oscilloscope (PAC 22) output. Voltage output. Zero adjustment by means of a thumb wheel (PAC 20) or automatically by simply pressing a pushbutton (PAC 21 and 22). "ON" indicator shows that battery is working satisfactorily and "OL" warns of low battery. Auto-power off, can be disabled, on PAC 21 and PAC 22. Standard: IEC 1010-1 Cat. III, deg. 2

Product Detail
New items
Chauvin Arnoux CA773 Voltage Indicator with RCD Trip Test Continuity Check CAT IV 1000 V

Chauvin Arnoux CA773 Voltage Indicator with RCD Trip Test Continuity Check CAT IV 1000 V

C.A 773 IP2X Voltage Absence Tester (VAT) CAT IV 1000V The C.A 773 IP2X Voltage Tester is a VAT with digital display and LEDs for voltages up to 1000 VAC/1400 VDC with with audible extended continuity and phase rotation testing. The Voltage Tester also offers trip testing of RCDs rated 30 mA (or less), as well as lighting of the test probe/point of measurement and digital display of the resistance and voltage. 1000 VAC / 1400 VDC Single-pole phase test Continuity andresistance test with audible and visual indication Two-pole phase sequence test with 2-wire method RCD trip testing and Detection of stray voltages Lighting of point of measurement. CAT IV 1000V IP65 Standards IEC 61243-3:2009, EN 61243-3:2010, IEC 61010 1,000 V CAT IV Supplied with Voltage absence tester, User's guide in 5 languages, 2 x 1.5 V LR03/AAA batteries, 1 set of IP2X removable test probes Ø 4 mm and 1 Velcro strap.

Product Detail
New items
RS PRO ICM133R Clamp Meter, Max Current 1kA ac CAT III 600 V With RS Calibration

RS PRO ICM133R Clamp Meter, Max Current 1kA ac CAT III 600 V With RS Calibration

ICM133R 1000A ac,True-rms reading 1000A ac current measurement 750Vac / 1000Vdc voltage measurement Large 51mm dia. conductor jaw capacity 4000 count backlit digital display with analogue bargraph True RMS reading on AC mode Resistance & continuity beeper Display Hold & Min Max Function 10ms Peak Hold on ac A & ac V Frequency Counter Auto Power Off (30 minutes) Separate battery compartment 600V circuit protection Complies with EN61010 CAT. III 600V Safety Standard for industrial applications Rugged construction with flame retardant, high impact plastic ac voltage Ranges 400V & 750V Resolution 0.1V & 1V Basic Accuracy ±(1.0% rdg+ 5d) 50 to 500Hz dc voltage Ranges 400V & 1000V Resolution 0.1V & 1V Basic Accuracy ±(0.7% rdg+ 2d) ac current Ranges 400A & 1000A Resolution 0.1A & 1A Basic Accuracy ±(1.9% rdg + 5d) 50-60Hz Resistance Range 400Ω Resolution 0.1Ω Basic Accuracy ±(1.0% rdg+ 3d) Frequency counter Ranges 4kHz & 10kHz Resolution 1Hz & 10Hz Basic Accuracy ±(0.1% + 2d) @5V rms max Size (WxHxD) and Weight 90 x 275 x 51mm, 420g Supplied with Test leads, carry case, instruction leaflet and 9V PP3 alkaline battery.

Product Detail
New items
Martindale MARVT25/PD Voltage Indicator & Proving Unit Kit

Martindale MARVT25/PD Voltage Indicator & Proving Unit Kit

Martindale Voltage Indicator and Proving Unit Kit MARVT25/PD Safe isolation procedures state that voltage indicators should be proved against a known source both before and after use. Martindale kit MARVT25/PD contains the VT25 voltage indicator and PD690 proving unit. These instruments are housed in a TC55 carry case with a neck strap, making it easy to carry and use the equipment on site. The VT25 is a two pole LED voltage indicator for use on AC or DC systems, displaying voltages from 12 V to 690 V. Additional functions of this model include audible and optical continuity, phase rotation and a single pole phase test. Safety features include a built-in torch and two layers of insulation on the cable. The inner layer insulation is a contrasting colour to the outer, making it easy to see if there has been any damage to the cable. The PD690 proving unit with this kit will light up all the LEDs on the indicator, enabling users to ensure the indicator is working correctly. The proving unit also features a low battery indicator. Standards BS EN61243-3:2010 CAT IV 600V, CAT III 1000V Supplied with Carry case, neck strap, AAA 1.5 V batteries (x2), instructions Martindale Lock-Off Kits, Voltage Indicators and Proving Units

Product Detail
New items
Weidmuller COMBI CHECK 1.3 Voltage Indicator Continuity Check

Weidmuller COMBI CHECK 1.3 Voltage Indicator Continuity Check

Combi Check Voltage Testers The main function of the voltage tester is to establish if voltage is present and display this value clearly. LEDs display the following voltages: 6,12, 24, 50, 120, 230, 400, 690 V High peak voltage strength 6 to 690 V measurement range Continuity testing Runs on 1 x AAA battery (supplied) Approvals VDE-Norm 0682, Section 401 Weidmuller Two Pole Voltage Testers

Product Detail
New items
Megger TDR900 TDR Cable Fault Locator, 3.7km

Megger TDR900 TDR Cable Fault Locator, 3.7km

Megger TDR 900 Handheld Time Domain Reflectometer/Cable LEngth Meter The Megger TDR900 is an advanced instrument capable of measuring cable lengths and finding distance to an open or a short using Time Domain Reflectometry. It offers exceptional features and a range capability normally associated with far more expensive instruments. The measurement range spans from 15 feet (5 m) to 10,000 feet (3 km) with a minimum resolution of 20 inches (50 cm). The TDR900 can be used for any cable consisting of at east two insulated metallic elements, one of which may be the sheath or shield of the cable. The Meter has automatic internal matching networks to allow testing of 25, 50, 75, 100, 125, or 150 cables. (These correspond to power, telephony, CATV, and LAN cables). Typical applications: Street lighting cable runs Outside broadcasting: check temporary cable installations Studio broadcasting: trailing camera cables, etc. Cable drops from aerials and antenna Stocktaking: measure cable lengths in stock, etc. CE-Certificated Accurate to 20 inches (50 cm) throughout the entire range Extra-large backlit (ICON type 7 segment) LCD Automatic output impedance control, auto-range, autozero, and auto-sensitivity allows for closely matching to a wide range of cables under test. Only V.O.P (velocity of propagation) settings required Displays cable length if the cable�s V.O.P (velocity of propagation) is known or displays V.O.P (velocity of propagation) if a cable�s length is known 20 internal memory locations store up to 20 custom cable V.O.P settings Internal library of 39 standard cables allow for quick and easy measurements for industry standard cable types Tone Generator (oscillating 910 to 1100 Hz; 5 V peak to peak) for cable identification and tracing Line Voltage Detection: Displays �OUCH� message and stops operation if line voltage exceeds 6.5 V Safety Protection (up to 250 V RMS) Supplied with ...

Product Detail
Next
FAQs

We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Electrical Test Equipment and all others.

You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Electrical Test Equipment or any other product.

This depends on the Electrical Test Equipment individual product and information that can be found on our website.

Yes, we offer special discounts on orders above £200 for Electrical Test Equipment and all other products.

UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Electrical Test Equipment.

Yes. We keep updating our stock frequently and if a product like Electrical Test Equipment is not in stock then we will let you know.