C.A 895 carbon monoxide detector
The C.A 895 detector measures carbon monoxide levels from 0 to 1000 ppm in ambient air.
2 measurement modes: "normal" for detecting CO source and "average" for precise measurement.
Continuous tone indicates exposure risk (Geiger counter principle).
Maximum value storage and hold function.
2000-point display.
Shockproof protective sheath.
A gas extraction kit with pump and extension piece is available separately.
Accuracy:
±5% or reading ±5 ppm (from 0 → 1000 ppm).
Response time:
70 seconds at 90% of measurement.
Dimensions:
237 x 60.5 x 38 mm
Weight:
190 g
Gas Detection: Carbon Monoxide Detection
Carbon Monoxide is a deadly toxic gas that has no smell and cannot be seen or tasted. Its presence is lethal causing death and injury, it can be caused by poorly installed or maintained heating appliances, chimneys, flues and gas fired cooking appliances.,Even low levels of CO can impair judgement and greatly increase risk of accidents and injury in motorists and machine operators. See "key characteristics" table for details of carbon monoxide level and their effects.
Key characteristics
Carbon Monoxide Level PPM
Effect
0
Desirable level
9
Maximum indoor air quality level
50
Max. concentration for continuous exposure in any 8hr period
200
Slight headache, tiredness, nausea after 2-3hrs.
300
Max. short term exposure limit (15 mins.)
400
Frontal headaches 1 to 2hrs, life threatening after 3hrs.
1600
Headache, dizziness, nausea within 20 minutes. Can prove fatal within 1hr
3200
Headache, dizziness, nausea within 10 minutes. Can prove fatal within 30 minutes