Fire Alarm Control Panels


FILTERS
Filters
Enrgtech #
Manufacturer Part No
Description
Availability
Rating
Eaton Fulleon
Rohs Verified
The Fulleon Bi-Wire Flexi 8 zone panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. It provides with the flexibility to utilize all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices. It provides a proven solution for simple programming and maintenance. Configure zone wiring to work as either a conventional or two-wire system Allows the connection of an existing conventional system to a BiWire system 8 zone panel Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A
Check Stock & Lead Times Packaging Options
Eaton Fulleon
Rohs Verified
The Fulleon Bi-Wire Flexi 2 zone panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. It provides with the flexibility to utilize all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices. It provides a proven solution for simple programming and maintenance. Configure zone wiring to work as either a conventional or two-wire system Allows the connection of an existing conventional system to a BiWire system 2 zone panel Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A
Check Stock & Lead Times Packaging Options
Rittal
Rohs Verified
The Rittal DK EFD III early fire detection system includes the smoke extraction system in a 482.6mm (19") sub rack with just 1 U. An integral fan continuously extracts air from the area being protected via a system of pipes. Tested by VdS Schadenverhütung GmbH CAN bus interface to the CMC III monitoring system
Check Stock & Lead Times Packaging Options
Rittal
Rohs Verified
The Rittal DK DET-AC III master system includes the smoke extraction system and the extinguisher unit. The smoke extraction system is identical to the smoke extraction system in the EFD III. Early fire detection Automatic extinguishing
Check Stock & Lead Times Packaging Options
Eaton Fulleon
Rohs Verified
The Fulleon Bi-Wire Flexi 4 zone panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. It provides with the flexibility to utilize all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices. It provides a proven solution for simple programming and maintenance. Configure zone wiring to work as either a conventional or two-wire system Allows the connection of an existing conventional system to a BiWire system 4 zone panel Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A
Check Stock & Lead Times Packaging Options
Eaton Fulleon
Rohs Verified
The Fulleon Conventional repeater panel is compatible with our 2 zone, 4 zone and 8 zone BiWire-Ultra (EFBWxZONE), BiWire-Flexi (EFBWxZFLEXI) and the latest release of conventional panels (EFCVxZ). It has Up to 3 EFBWCV repeater panels can be daisy-chained to a single control panel, allowing all repeater panels to replicate the visual and audible fire and fault information of the control panel. With an integral power supply the only wiring required for the repeater panel is the mains input to the power supply unit and the data cable between the fire control panel and each repeater panel. Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A Operating temperature ranges from -5°C to +40°C Up to 3 repeaters per control panel
Check Stock & Lead Times Packaging Options
Rittal
Rohs Verified
The Rittal DK DET-AC III slave add-on unit to the DET AC III Master includes an additional extinguisher unit. In addition to the DET-AC III unit, a DET-AC III slave unit is used for each additional bayed enclosure and supplies the extinguishing agent for CAN bus interface to the CMC III monitoring system In conjunction with the DET-AC III Master, extinguishes up to five racks in an enclosure suite May be used in combination with EFD III
Check Stock & Lead Times Packaging Options
Alarm System Control Panel Fire alarm control panels designed to comply with EN54 Parts 2 & 4 and suitable for installations meeting BS5839 Part 1. Easy to install, with clear fire/fault indication Programmable with option for zone and sounder configurations Integral PSU and battery support for up to 8 alarms sounder circuits, 2 auxiliary relay contacts and zone disable facility Suitable for automatic detectors, manual call points, or a combination of both Includes an external evacuation facility Detectors and manual call points can be wired in any order Detector removal monitoring via diode base Auto reset function and silent maintenance tests configured by each individual zone Any zone can be selected for special fire activities, zones may be disabled at any time Keypad access with password protection Batteries provide 72 hour standby Detection circuits 24 (max) per zone @ 16V (min quiescent) 20mA @ 7V across trigger devices 27mA @ 0V fire voltage Alarm circuits 2 per panel (min), 8 on 8 Zone panel 1A (max) load on 1&2 Zone panels 1·5A (max) load on 4&8 Zone panels Auxilary relay contacts 1 set N/O and 1 set N/C, rated 1A @ 24Vdc Class Change 1 pair N/O un-monitored terminals operated via external remote Fault Monitoring Zones; Open/Short circuit via end-of-line capacitor and polarising diode Alarm Circuits: Open/Short circuit with 22kΩ end-of-line resistor Other; Earth/Fault, battery charger, mains power and fuse state Controls Sound Alarms, Silence Alarms, Reset, Cancel Fault Buzzer, Lamp Test, Disable Zone Batteries (not supplied) 1&2 Zone (2x12V 2Ah 597-813 ) 4&8 Zone (2x12V 2.8Ah 597-829 ) Gent Smoke and Heat Detectors Providing a comprehensive range of sensing devices for use on DC monitored, automatic fire detection systems, this series of smoke and sensing devices has been designed to provide easy installation and...
Check Stock & Lead Times Packaging Options
Alarm System Control Panel Fire alarm control panels designed to comply with EN54 Parts 2 & 4 and suitable for installations meeting BS5839 Part 1. Easy to install, with clear fire/fault indication Programmable with option for zone and sounder configurations Integral PSU and battery support for up to 8 alarms sounder circuits, 2 auxiliary relay contacts and zone disable facility Suitable for automatic detectors, manual call points, or a combination of both Includes an external evacuation facility Detectors and manual call points can be wired in any order Detector removal monitoring via diode base Auto reset function and silent maintenance tests configured by each individual zone Any zone can be selected for special fire activities, zones may be disabled at any time Keypad access with password protection Batteries provide 72 hour standby Detection circuits 24 (max) per zone @ 16V (min quiescent) 20mA @ 7V across trigger devices 27mA @ 0V fire voltage Alarm circuits 2 per panel (min), 8 on 8 Zone panel 1A (max) load on 1&2 Zone panels 1·5A (max) load on 4&8 Zone panels Auxilary relay contacts 1 set N/O and 1 set N/C, rated 1A @ 24Vdc Class Change 1 pair N/O un-monitored terminals operated via external remote Fault Monitoring Zones; Open/Short circuit via end-of-line capacitor and polarising diode Alarm Circuits: Open/Short circuit with 22kΩ end-of-line resistor Other; Earth/Fault, battery charger, mains power and fuse state Controls Sound Alarms, Silence Alarms, Reset, Cancel Fault Buzzer, Lamp Test, Disable Zone Batteries (not supplied) 1&2 Zone (2x12V 2Ah 597-813 ) 4&8 Zone (2x12V 2.8Ah 597-829 ) Gent Smoke and Heat Detectors Providing a comprehensive range of sensing devices for use on DC monitored, automatic fire detection systems, this series of smoke and sensing devices has been designed to provide easy installation and maintenance with full detector interchangeability. Particular emphasis has been given to the overall series des...
Check Stock & Lead Times Packaging Options

8 Zone Auto Reset Fire Alarm Control Panel

2 Zone Auto Reset Fire Alarm Control Panel

Fire Alarm Control Panel

Fire Alarm Control Panel

4 Zone Auto Reset Fire Alarm Control Panel

Fire Alarm Control Panel

8 Zone Auto Reset Fire Alarm Control Panel

2 Zone Auto Reset Fire Alarm Control Panel


New Items
New items
8 Zone Auto Reset Fire Alarm Control Panel

8 Zone Auto Reset Fire Alarm Control Panel

The Fulleon Bi-Wire Flexi 8 zone panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. It provides with the flexibility to utilize all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices. It provides a proven solution for simple programming and maintenance. Configure zone wiring to work as either a conventional or two-wire system Allows the connection of an existing conventional system to a BiWire system 8 zone panel Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A
New items
2 Zone Auto Reset Fire Alarm Control Panel

2 Zone Auto Reset Fire Alarm Control Panel

The Fulleon Bi-Wire Flexi 2 zone panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. It provides with the flexibility to utilize all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices. It provides a proven solution for simple programming and maintenance. Configure zone wiring to work as either a conventional or two-wire system Allows the connection of an existing conventional system to a BiWire system 2 zone panel Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A
New items
Fire Alarm Control Panel

Fire Alarm Control Panel

The Rittal DK EFD III early fire detection system includes the smoke extraction system in a 482.6mm (19") sub rack with just 1 U. An integral fan continuously extracts air from the area being protected via a system of pipes. Tested by VdS Schadenverhütung GmbH CAN bus interface to the CMC III monitoring system
New items
Fire Alarm Control Panel

Fire Alarm Control Panel

The Rittal DK DET-AC III master system includes the smoke extraction system and the extinguisher unit. The smoke extraction system is identical to the smoke extraction system in the EFD III. Early fire detection Automatic extinguishing
New items
4 Zone Auto Reset Fire Alarm Control Panel

4 Zone Auto Reset Fire Alarm Control Panel

The Fulleon Bi-Wire Flexi 4 zone panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. It provides with the flexibility to utilize all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices. It provides a proven solution for simple programming and maintenance. Configure zone wiring to work as either a conventional or two-wire system Allows the connection of an existing conventional system to a BiWire system 4 zone panel Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A
New items
2, 4, 8 Zone Auto Reset Fire Alarm Control Panel

2, 4, 8 Zone Auto Reset Fire Alarm Control Panel

The Fulleon Conventional repeater panel is compatible with our 2 zone, 4 zone and 8 zone BiWire-Ultra (EFBWxZONE), BiWire-Flexi (EFBWxZFLEXI) and the latest release of conventional panels (EFCVxZ). It has Up to 3 EFBWCV repeater panels can be daisy-chained to a single control panel, allowing all repeater panels to replicate the visual and audible fire and fault information of the control panel. With an integral power supply the only wiring required for the repeater panel is the mains input to the power supply unit and the data cable between the fire control panel and each repeater panel. Input voltage range 18.75 to 30.7V Maximum current drawn from battery 2.7A Operating temperature ranges from -5°C to +40°C Up to 3 repeaters per control panel
New items
Fire Alarm Control Panel

Fire Alarm Control Panel

The Rittal DK DET-AC III slave add-on unit to the DET AC III Master includes an additional extinguisher unit. In addition to the DET-AC III unit, a DET-AC III slave unit is used for each additional bayed enclosure and supplies the extinguishing agent for CAN bus interface to the CMC III monitoring system In conjunction with the DET-AC III Master, extinguishes up to five racks in an enclosure suite May be used in combination with EFD III
New items
8 Zone Auto Reset Fire Alarm Control Panel

8 Zone Auto Reset Fire Alarm Control Panel

Alarm System Control Panel Fire alarm control panels designed to comply with EN54 Parts 2 & 4 and suitable for installations meeting BS5839 Part 1. Easy to install, with clear fire/fault indication Programmable with option for zone and sounder configurations Integral PSU and battery support for up to 8 alarms sounder circuits, 2 auxiliary relay contacts and zone disable facility Suitable for automatic detectors, manual call points, or a combination of both Includes an external evacuation facility Detectors and manual call points can be wired in any order Detector removal monitoring via diode base Auto reset function and silent maintenance tests configured by each individual zone Any zone can be selected for special fire activities, zones may be disabled at any time Keypad access with password protection Batteries provide 72 hour standby Detection circuits 24 (max) per zone @ 16V (min quiescent) 20mA @ 7V across trigger devices 27mA @ 0V fire voltage Alarm circuits 2 per panel (min), 8 on 8 Zone panel 1A (max) load on 1&2 Zone panels 1·5A (max) load on 4&8 Zone panels Auxilary relay contacts 1 set N/O and 1 set N/C, rated 1A @ 24Vdc Class Change 1 pair N/O un-monitored terminals operated via external remote Fault Monitoring Zones; Open/Short circuit via end-of-line capacitor and polarising diode Alarm Circuits: Open/Short circuit with 22kΩ end-of-line resistor Other; Earth/Fault, battery charger, mains power and fuse state Controls Sound Alarms, Silence Alarms, Reset, Cancel Fault Buzzer, Lamp Test, Disable Zone Batteries (not supplied) 1&2 Zone (2x12V 2Ah 597-813 ) 4&8 Zone (2x12V 2.8Ah 597-829 ) Gent Smoke and Heat Detectors Providing a comprehensive range of sensing devices for use on DC monitored, automatic fire detection systems, this series of smoke and sensing devices has been designed to provide easy installation and...
New items
2 Zone Auto Reset Fire Alarm Control Panel

2 Zone Auto Reset Fire Alarm Control Panel

Alarm System Control Panel Fire alarm control panels designed to comply with EN54 Parts 2 & 4 and suitable for installations meeting BS5839 Part 1. Easy to install, with clear fire/fault indication Programmable with option for zone and sounder configurations Integral PSU and battery support for up to 8 alarms sounder circuits, 2 auxiliary relay contacts and zone disable facility Suitable for automatic detectors, manual call points, or a combination of both Includes an external evacuation facility Detectors and manual call points can be wired in any order Detector removal monitoring via diode base Auto reset function and silent maintenance tests configured by each individual zone Any zone can be selected for special fire activities, zones may be disabled at any time Keypad access with password protection Batteries provide 72 hour standby Detection circuits 24 (max) per zone @ 16V (min quiescent) 20mA @ 7V across trigger devices 27mA @ 0V fire voltage Alarm circuits 2 per panel (min), 8 on 8 Zone panel 1A (max) load on 1&2 Zone panels 1·5A (max) load on 4&8 Zone panels Auxilary relay contacts 1 set N/O and 1 set N/C, rated 1A @ 24Vdc Class Change 1 pair N/O un-monitored terminals operated via external remote Fault Monitoring Zones; Open/Short circuit via end-of-line capacitor and polarising diode Alarm Circuits: Open/Short circuit with 22kΩ end-of-line resistor Other; Earth/Fault, battery charger, mains power and fuse state Controls Sound Alarms, Silence Alarms, Reset, Cancel Fault Buzzer, Lamp Test, Disable Zone Batteries (not supplied) 1&2 Zone (2x12V 2Ah 597-813 ) 4&8 Zone (2x12V 2.8Ah 597-829 ) Gent Smoke and Heat Detectors Providing a comprehensive range of sensing devices for use on DC monitored, automatic fire detection systems, this series of smoke and sensing devices has been designed to provide easy installation and maintenance with full detector interchangeability. Particular emphasis has been given to the overall series des...
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Fire Alarm Control Panels and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Fire Alarm Control Panels or any other product.
This depends on the Fire Alarm Control Panels individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Fire Alarm Control Panels and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Fire Alarm Control Panels.
Yes. We keep updating our stock frequently and if a product like Fire Alarm Control Panels is not in stock then we will let you know.