Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Products Found: 439

Showing Results For: PCB Transformers

PCB Transformers


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Rohs Verified
PCS040-EF1305KS, Bourns
298 In Stock
Check Stock & Lead Times Packaging Options
300 +
£ 2.30
Rohs Verified
PCS040-EF1303KS, Bourns
298 In Stock
Check Stock & Lead Times Packaging Options
300 +
£ 2.30
Rohs Verified
PCS040-EF1334KS, Bourns
298 In Stock
Check Stock & Lead Times Packaging Options
300 +
£ 2.30
Rohs Verified
PCS020-EE0503KS, Bourns
998 In Stock
Check Stock & Lead Times Packaging Options
1000 +
£ 2.13
Rohs Verified
PCS020-EE05730S, Bourns
998 In Stock
Check Stock & Lead Times Packaging Options
1000 +
£ 2.13
Rohs Verified
PCS020-EE0502KS, Bourns
998 In Stock
Check Stock & Lead Times Packaging Options
1000 +
£ 2.13
Rohs Verified
PCS040-EF1301KS, Bourns
298 In Stock
Check Stock & Lead Times Packaging Options
300 +
£ 2.30
Rohs Verified
PCS020-EE05320S, Bourns
2044 In Stock
Check Stock & Lead Times Packaging Options
1000 +
£ 2.32
Rohs Verified
PCS040-EF1319KS, Bourns
298 In Stock
Check Stock & Lead Times Packaging Options
300 +
£ 2.30
Rohs Verified
PCS020-EE05081S, Bourns
2043 In Stock
Check Stock & Lead Times Packaging Options
1000 +
£ 2.50
Rohs Verified
PFBR45-SP13150S, Bourns
450 In Stock
Check Stock & Lead Times Packaging Options
200 +
£ 2.53
Rohs Verified
PFBR45-ST13150S, Bourns
411 In Stock
Check Stock & Lead Times Packaging Options
180 +
£ 2.66
Rohs Verified
B78416A2232A003, EPCOS
898 In Stock
Check Stock & Lead Times Packaging Options
900 +
£ 2.24
Rohs Verified
SM91502ALA-E, Bourns
1677 In Stock
Check Stock & Lead Times Packaging Options
800 +
£ 1.20
Rohs Verified
SM91501ALO-E, Bourns
1598 In Stock
Check Stock & Lead Times Packaging Options
400 +
£ 2.04
Rohs Verified
SM91514AL-E, Bourns
792 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 2.05
10 +
£ 1.62
50 +
£ 1.57
Wurth Elektronik
Rohs Verified
749252060, Wurth Elektronik
4076 In Stock
Check Stock & Lead Times Packaging Options
2000 +
£ 3.36
Wurth Elektronik
Rohs Verified
749252030, Wurth Elektronik
4074 In Stock
Check Stock & Lead Times Packaging Options
2000 +
£ 3.36
Wurth Elektronik
Rohs Verified
749252070, Wurth Elektronik
4077 In Stock
Check Stock & Lead Times Packaging Options
2000 +
£ 3.36
Wurth Elektronik
Rohs Verified
749252040, Wurth Elektronik
4075 In Stock
Check Stock & Lead Times Packaging Options
2000 +
£ 3.36
Wurth Elektronik
Rohs Verified
749252125, Wurth Elektronik
4078 In Stock
Check Stock & Lead Times Packaging Options
2000 +
£ 3.36
Rohs Verified
MTPL-2516-S12V, Vishay
80 In Stock
Check Stock & Lead Times Packaging Options
25 +
£ 12.84
Rohs Verified
MTPL-2516-S24V, Vishay
82 In Stock
Check Stock & Lead Times Packaging Options
25 +
£ 12.84
50 +
£ 12.48
Myrra
Rohs Verified
47215, Myrra
20 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 18.41
5 +
£ 17.10
10 +
£ 15.68
Myrra
Rohs Verified
47210, Myrra
51 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 16.72
5 +
£ 15.53
10 +
£ 14.25
Showing
1 -

New Items
New items
VCM 50/1/6, Block

VCM 50/1/6, Block

PCB Mount 230Vac Primary VC/VCM Series Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise 100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA) Selection Guide VA Rating Pin configuration (mm) P1 S1 S2 A 3.2VA 20 10 5 25 5VA 25 15 5 25 10VA 25 15 5 27.5 16VA 30 20 5 30 Selection Guide VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A 25VA 72.5 43.5 30 20 5 32.5 36VA 77.5 47.5 35 20 5 35 50VA 82 37.5 35 15 - 35 Isolation Primary to Secondary 5kVac Secondary to Secondary 250Vac Protection Class 2 Insulation Class B (130°C) Pin Length x Diameter 5mm x 0.8mm Max. Ambient Temperature 3.2VA +60°C,5VA +50°C, 10 to 36VA +40°C Note To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series. Standards EN 61 558 IEC 61558 Approvals ENEC, UL recognised Approvals VDE; UL Standards EN 61 558; IEC 61558
New items
PT 13/2/9, Block

PT 13/2/9, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø 1.5 20 10 20 0.8 Ø 2.0 20 10 ...
New items
FL 14/6, Block

FL 14/6, Block

PCB Mounting Low Profile 115 / 230Vac Primary Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing holes for secure board mounting Standard: EN60742, VDE 0551, IEC 61558 Selection Guide VA Rating Fixing Centres Pin Configuration C1 C2 P1 P2 S1 S2 A 4 VA 37.5 47.5 15 10 25 5 35 6 VA 37.5 47.5 15 10 25 5 35 10 VA 50 62.5 16 15 26 10 45 14 VA 50 62.5 16 15 26 10 45 18 VA 50 62.5 16 15 26 10 45 24 VA 50 62.5 16 15 26 10 45 30 VA 50 62.5 16 15 26 10 45 42 VA 60 75 27 15 37 10 53.5 52 VA 60 75 27 15 37 10 53.5 Isolation Primary to secondary 5kV Primary to primary 1kV Secondary to secondary 250V Protection Class 2 Insulation Class E (120°C) Class A (105°C) Max. Ambient Temperature +40°C Pin Diameter (mm) 0.8 mm Fixing: mechanical fixings can be supplemented by 4 self tapping screws (no. 4 x 9.5mm max. on the 2VA to 30VA transformers and M3 on the 42 and 52VA transformers) using holes mounted in the corners of the case Note: For conformance reasons, transformer with 2 x 24V outputs should not have their secondaries connected in series Note Transformer with 2 x 24V outputs are not VDE, SEV approved. Standards VD 61 558
New items
44441, Myrra

44441, Myrra

Type EI 60 / 21.2 → 22 VA transformers Secondary voltages are nominal load voltages on resistive loads. Primary voltage: 230 V Current consumption: 125 mA Height (mm) - transformer:  47.75 - soldering pins:  4.5 Total P / S insulation: > 4000 V Pins: - primary: 1 → 7 - 2 secondaries: 8 → 9  13 → 14 Approvals UL, VDE Encapsulated – Toroidal Maximum Operating Temperature +60°C Primary – Secondary Test Voltage 4 kV UL Recognised for Insulation Class A +105°C Meets All Requirements of Class E +120°C Pin Length x Diameter 1 x 0.5 mm Note Fixing screws not provided
New items
PCS020-EE0503KS, Bourns

PCS020-EE0503KS, Bourns

The Bourns PCS series current sense transformer is suitable for frequency up to 1 MHz. It has 500 Vrms isolation between windings. It is suitable for switched-mode power supplies, motor control, overload sensing, and AC current applications. Rated current on primary up to 20 A Operating temperature range from 40 °C to 125 °C
New items
PT 22/2/15, Block

PT 22/2/15, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø 1.5 20 ...
New items
VB 1.5/2/9, Block

VB 1.5/2/9, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø ...
New items
FL 24/9, Block

FL 24/9, Block

PCB Mounting Low Profile 115 / 230Vac Primary Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing holes for secure board mounting Standard: EN60742, VDE 0551, IEC 61558 Selection Guide VA Rating Fixing Centres Pin Configuration C1 C2 P1 P2 S1 S2 A 4 VA 37.5 47.5 15 10 25 5 35 6 VA 37.5 47.5 15 10 25 5 35 10 VA 50 62.5 16 15 26 10 45 14 VA 50 62.5 16 15 26 10 45 18 VA 50 62.5 16 15 26 10 45 24 VA 50 62.5 16 15 26 10 45 30 VA 50 62.5 16 15 26 10 45 42 VA 60 75 27 15 37 10 53.5 52 VA 60 75 27 15 37 10 53.5 Isolation Primary to secondary 5kV Primary to primary 1kV Secondary to secondary 250V Protection Class 2 Insulation Class E (120°C) Class A (105°C) Max. Ambient Temperature +40°C Pin Diameter (mm) 0.8 mm Fixing: mechanical fixings can be supplemented by 4 self tapping screws (no. 4 x 9.5mm max. on the 2VA to 30VA transformers and M3 on the 42 and 52VA transformers) using holes mounted in the corners of the case Note: For conformance reasons, transformer with 2 x 24V outputs should not have their secondaries connected in series Note Transformer with 2 x 24V outputs are not VDE, SEV approved. Standards VD 61 558
New items
FL 42/12, Block

FL 42/12, Block

PCB Mounting Low Profile 115 / 230Vac Primary Twin 115Va.c. 50 to 60Hz primary windings for series or parallel connection Twin secondary windings for series or parallel connection Low profile compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested Low inter-winding capacitance Low radiated noise Extra fixing holes for secure board mounting Standard: EN60742, VDE 0551, IEC 61558 Selection Guide VA Rating Fixing Centres Pin Configuration C1 C2 P1 P2 S1 S2 A 4 VA 37.5 47.5 15 10 25 5 35 6 VA 37.5 47.5 15 10 25 5 35 10 VA 50 62.5 16 15 26 10 45 14 VA 50 62.5 16 15 26 10 45 18 VA 50 62.5 16 15 26 10 45 24 VA 50 62.5 16 15 26 10 45 30 VA 50 62.5 16 15 26 10 45 42 VA 60 75 27 15 37 10 53.5 52 VA 60 75 27 15 37 10 53.5 Isolation Primary to secondary 5kV Primary to primary 1kV Secondary to secondary 250V Protection Class 2 Insulation Class E (120°C) Class A (105°C) Max. Ambient Temperature +40°C Pin Diameter (mm) 0.8 mm Fixing: mechanical fixings can be supplemented by 4 self tapping screws (no. 4 x 9.5mm max. on the 2VA to 30VA transformers and M3 on the 42 and 52VA transformers) using holes mounted in the corners of the case Note: For conformance reasons, transformer with 2 x 24V outputs should not have their secondaries connected in series Note Transformer with 2 x 24V outputs are not VDE, SEV approved. Standards VD 61 558
New items
VB 3.2/2/12, Block

VB 3.2/2/12, Block

Transformers PCB Mount, Short Circuit Proof, VB & PT Series 230Va.c. 50 to 60Hz primary Single or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their secondaries connected in series as this means they will not meet the VDE 0550 approval) VB series (0.35 - 3.2VA) are inherently short circuit proof PT series (4.5 - 22VA) are protected by internal PTC device Compact design Vacuum epoxy resin moulded to UL94-V0 rating Double section glass fibre reinforced polyamide bobbins 100% electrical and flash tested High efficiency and low temperature rise Low inter-winding capacitance Low radiated noise Extra fixing holes for secure boarding mounting on 4.5VA and above Selection Guide (Dual secondary) VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A Pin Size 0.35 - - 15 5 5 15 0.6 Ø 0.5 - - 15 5 5 15 0.6 Ø 1.0 - - 20 10 5 20 0.8 Ø 1.5 - - 20 10 5 20 0.8 Ø 2.3 - - 20 10 5 20 0.8 Ø 3.2 - - 20 10 5 25 0.8 Ø 4.5 35 28 25 15 5 25 0.8 Ø 7.5 40 32 25 15 5 27.5 0.8 Ø 13 47.5 37.5 30 20 5 30 0.8 Ø 22 52.5 40 30 10 10 32.5 0.8 Ø Isolation Primary to Secondary 5kV Secondary to Secondary 250V Protection Class 2 Insulation: VB Series PT Series Class B (130°C) Class A (105°C) Class E (120°C) Class A (105°C) Fixing: mechanical fixings can be supplemented on the 4.5 to 22VA transformers by 4 self tapping crews (No-4 x 9.5mm max) using holes mounted in the corners of the case. Max Ambient Temperature 0.35 to 2.3VA +70°C, 3.2VA +50°C, 4.5 to 22VA +40°C Selection Guide (Single secondary) VA Rating Pin configuration (mm) P1 S1 A Pin Size 0.35 15 5 15 0.6 Ø 0.5 15 5 15 0.6 Ø 1.0 20 10 20 0.6 Ø 1.2 20 10 20 0.8 Ø 1.5 20 ...
New items
VCM 25/2/12, Block

VCM 25/2/12, Block

PCB Mount 230Vac Primary VC/VCM Series Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise 100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA) Selection Guide VA Rating Pin configuration (mm) P1 S1 S2 A 3.2VA 20 10 5 25 5VA 25 15 5 25 10VA 25 15 5 27.5 16VA 30 20 5 30 Selection Guide VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A 25VA 72.5 43.5 30 20 5 32.5 36VA 77.5 47.5 35 20 5 35 50VA 82 37.5 35 15 - 35 Isolation Primary to Secondary 5kVac Secondary to Secondary 250Vac Protection Class 2 Insulation Class B (130°C) Pin Length x Diameter 5mm x 0.8mm Max. Ambient Temperature 3.2VA +60°C,5VA +50°C, 10 to 36VA +40°C Note To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series. Standards EN 61 558 IEC 61558 Approvals ENEC, UL recognised
New items
VC 10/2/15, Block

VC 10/2/15, Block

PCB Mount 230Vac Primary VC/VCM Series Single and twin secondary windings for series or parallel connection Vacuum resin moulded to UL94-V0 rating Low inter-winding capacitance Low radiated noise 100% electrical and flash tested Extra fixing points for secure board mounting (25 VA and 36 VA) Selection Guide VA Rating Pin configuration (mm) P1 S1 S2 A 3.2VA 20 10 5 25 5VA 25 15 5 25 10VA 25 15 5 27.5 16VA 30 20 5 30 Selection Guide VA Rating Fixing centres (mm) Pin configuration (mm) C1 C2 P1 S1 S2 A 25VA 72.5 43.5 30 20 5 32.5 36VA 77.5 47.5 35 20 5 35 50VA 82 37.5 35 15 - 35 Isolation Primary to Secondary 5kVac Secondary to Secondary 250Vac Protection Class 2 Insulation Class B (130°C) Pin Length x Diameter 5mm x 0.8mm Max. Ambient Temperature 3.2VA +60°C,5VA +50°C, 10 to 36VA +40°C Note To conform to VDE 0550,UL506 all transformers with 2 x 24V outputs should not have their secondaries connected in series. Standards EN 61 558 IEC 61558 Approvals ENEC, UL recognised
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like PCB Transformers and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding PCB Transformers or any other product.
This depends on the PCB Transformers individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for PCB Transformers and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including PCB Transformers.
Yes. We keep updating our stock frequently and if a product like PCB Transformers is not in stock then we will let you know.