Spirax Sarco
Automatic Air Vent AE30B and AE30C The AE30 range of automatic air eliminators have been specifically designed for the removal of air from industrial and commercial hot and chilled water systems. Versions AE30B and AE30C have a 3 way locking system which enables the valve to be either locked open, locked close or used as a ball valve. Materials of construction comply with the requirements of the Water Research Centre (WRc) and M&E3 Reliable, leak free operation Compact body design AE30B and AE30C have a lockshield fitted as standard One valve covers all operating conditions making selection and replacement simple Simple lever and float operation Note A standard socket set will be required to operate the valve Standards 97/23/EC Approvals WRc; M&E3 Valve Data Approvals WRc M&E3 Body Design Conditions PN10 Body and Cap Material BS 2872 CZ 132 DZR Copper Alloy Cap O Ring Material WRc 9305512 Green Viton 75 Cold Hydraulic Test Pressure 15 bar g Connections (in. BSP M) Outlet 1//4 in. Connections (in. BSPP F) Inlet 1//2 in. Float Material Acetal Co Hostaform Stainless Steel Lockshield Valve Body, AE30B/AE30C BS 2872 CZ 132 DZR Copper Alloy Maximum Differential Pressure 8 bar Maximum Operating Pressure 10 bar g Maximum Operating Temperature 110°C Minimum Specific Gravity Of Water 0.926 Maximum Allowable Temperature 150 C Maximum Allowable Pressure 10 bar g Overall Body Diameter 56 mm Outlet Centre Offset 10 mm
Check Stock & Lead Times Packaging Options
Spirax Sarco
Automatic Air Vent AE30B and AE30C The AE30 range of automatic air eliminators have been specifically designed for the removal of air from industrial and commercial hot and chilled water systems. Versions AE30B and AE30C have a 3 way locking system which enables the valve to be either locked open, locked close or used as a ball valve. Materials of construction comply with the requirements of the Water Research Centre (WRc) and M&E3 Reliable, leak free operation Compact body design AE30B and AE30C have a lockshield fitted as standard One valve covers all operating conditions making selection and replacement simple Simple lever and float operation Note A standard socket set will be required to operate the valve Standards 97/23/EC Approvals WRc; M&E3 Valve Data Approvals WRc M&E3 Body Design Conditions PN10 Body and Cap Material BS 2872 CZ 132 DZR Copper Alloy Cap O Ring Material WRc 9305512 Green Viton 75 Cold Hydraulic Test Pressure 15 bar g Connections (in. BSP M) Outlet 1//4 in. Connections (in. BSPP F) Inlet 1//2 in. Float Material Acetal Co Hostaform Stainless Steel Lockshield Valve Body, AE30B/AE30C BS 2872 CZ 132 DZR Copper Alloy Maximum Differential Pressure 8 bar Maximum Operating Pressure 10 bar g Maximum Operating Temperature 110°C Minimum Specific Gravity Of Water 0.926 Maximum Allowable Temperature 150 C Maximum Allowable Pressure 10 bar g Overall Body Diameter 56 mm Outlet Centre Offset 10 mm
Check Stock & Lead Times Packaging Options
Spirax Sarco
Automatic Air Vent AE30A Air eliminators AE30 and AE30A have been specifically designed for the removal of air and other non-condensible gases from industrial and commercial hot and chilled water systems. This then improves the circulation of the pressurized liquids. Typical areas where this can be applied are, suction lines to pumps, water storage tanks, mixing tanks and cold water lines. Materials of construction comply with the requirements of the Water Research Centre (WRc) and M&E3 Reliable, leak free operation AE30A has inbuilt check valve Compact body design One valve covers all operating conditions making selection and replacement simple Simple lever and float operation Valve Data Approvals WRc M&E3 Body Design Conditions PN10 Body and Cap Material BS 2872 CZ 132 DZR Copper Alloy Cap O Ring Material WRc 9305512 Green Viton 75 Cold Hydraulic Test Pressure 15 bar g Connections (in. BSP M) Outlet 1//4 in. Connections (in. BSPP F) Inlet 1//2 in. Float Material Acetal Co Hostaform Stainless Steel Lockshield Valve Body, AE30B/AE30C BS 2872 CZ 132 DZR Copper Alloy Maximum Differential Pressure 8 bar Maximum Operating Pressure 10 bar g Maximum Operating Temperature 110°C Minimum Specific Gravity Of Water 0.926 Maximum Allowable Temperature 150 C Maximum Allowable Pressure 10 bar g Overall Body Diameter 56 mm Outlet Centre Offset 10 mm
Check Stock & Lead Times Packaging Options
Valsteam ADCA
Air Eliminator for Water Systems The AE16SS stainless steel air eliminator removes air from HVAC systems and is also suitable for non corrosive and/or dangerous liquids providing that their specific weight is not less than 0,75Kg/dm3. This ball float type automatic air eliminator can be used in combination with other air elimination and separation systems or directly applied at high points in the piping Connections are female screwed Vertical installation Corrosion-resistant Replaceable internal parts Cold and hot water systems Note It must be installed absolutely vertically at the points in the plant where the air tends to collect. The drain should be piped to a safe position Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
Check Stock & Lead Times Packaging Options
Valsteam ADCA
Vacuum Breaker The VB21 vacuum breakers are simple and reliable devices that automatically relieve or "break" an unwanted vacuum condition, restoring the atmospheric pressure. This device is particularly suitable for steam heated units of small and medium volume as heat exchangers, heating coils, calorifiers, jacketed kettles, steam boilers, etc. Connections are female screwed Note Vertical installation angled connection Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
Check Stock & Lead Times Packaging Options
Reliance Water Controls
Automatic Air Vent High quality automatic air vents for use in heating systems to vent air when commissioning a system. The device consists of a polypropylene float connected to a simple valve. When the build-up of air within the float chamber exceeds a certain level the float drops, opening the valve and releasing the air trapped within the chamber. As the air is released, water replaces it, and moves the float back into the up position, which closes the valve Max. working pressure: 10 bar Max. working temperature: 110゚C Body: Standard brass Cap: Standard brass Float: Heat resistant polypropylene Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
Check Stock & Lead Times Packaging Options
Check Stock & Lead Times Packaging Options
Spirax Sarco
Thermostatic Air Vent AV13 Body design conditions PN16 Valve body and cap in brass to BS2872 CZ122 Stainless steel capsule Strainer in stainless steel to ASTM A240 TP 304 Synthetic rubber high fluorine fluorocarbon O-rings Cold hydraulic test pressure 24 bar g Maximum operating pressure (saturated steam) 13 bar g Maximum operating temperature 260°C Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
Check Stock & Lead Times Packaging Options
Reliance Water Controls
Automatic Air Vent High quality automatic air vents for use in heating systems to vent air when commissioning a system. The device consists of a polypropylene float connected to a simple valve. When the build-up of air within the float chamber exceeds a certain level the float drops, opening the valve and releasing the air trapped within the chamber. As the air is released, water replaces it, and moves the float back into the up position, which closes the valve Max. working pressure: 10 bar Max. working temperature: 110゚C Body: Standard brass Cap: Standard brass Float: Heat resistant polypropylene Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
Check Stock & Lead Times Packaging Options

Spirax Sarco Air Vent, AE30C 1/2 in BSP, 1/4 in BSP

Spirax Sarco Air Vent, AE30B 1/2 in BSP, 1/4 in BSP

Spirax Sarco Air Vent, AE30A 1/2 in BSPP 1/4 in BSP

Valsteam ADCA Air Vent AE16SS12 1/2 in

Valsteam ADCA Air Vent 345063 1/2 in, 1/8 in

Automatic air vent valve MV 10-R

Spirax Sarco Air Vent, AV13 1/2 in BSPP


New Items
New items
Spirax Sarco Air Vent, AE30B 1/2 in BSP, 1/4 in BSP

Spirax Sarco Air Vent, AE30B 1/2 in BSP, 1/4 in BSP

Automatic Air Vent AE30B and AE30C The AE30 range of automatic air eliminators have been specifically designed for the removal of air from industrial and commercial hot and chilled water systems. Versions AE30B and AE30C have a 3 way locking system which enables the valve to be either locked open, locked close or used as a ball valve. Materials of construction comply with the requirements of the Water Research Centre (WRc) and M&E3 Reliable, leak free operation Compact body design AE30B and AE30C have a lockshield fitted as standard One valve covers all operating conditions making selection and replacement simple Simple lever and float operation Note A standard socket set will be required to operate the valve Standards 97/23/EC Approvals WRc; M&E3 Valve Data Approvals WRc M&E3 Body Design Conditions PN10 Body and Cap Material BS 2872 CZ 132 DZR Copper Alloy Cap O Ring Material WRc 9305512 Green Viton 75 Cold Hydraulic Test Pressure 15 bar g Connections (in. BSP M) Outlet 1//4 in. Connections (in. BSPP F) Inlet 1//2 in. Float Material Acetal Co Hostaform Stainless Steel Lockshield Valve Body, AE30B/AE30C BS 2872 CZ 132 DZR Copper Alloy Maximum Differential Pressure 8 bar Maximum Operating Pressure 10 bar g Maximum Operating Temperature 110°C Minimum Specific Gravity Of Water 0.926 Maximum Allowable Temperature 150 C Maximum Allowable Pressure 10 bar g Overall Body Diameter 56 mm Outlet Centre Offset 10 mm
New items
Spirax Sarco Air Vent, AE30C 1/2 in BSP, 1/4 in BSP

Spirax Sarco Air Vent, AE30C 1/2 in BSP, 1/4 in BSP

Automatic Air Vent AE30B and AE30C The AE30 range of automatic air eliminators have been specifically designed for the removal of air from industrial and commercial hot and chilled water systems. Versions AE30B and AE30C have a 3 way locking system which enables the valve to be either locked open, locked close or used as a ball valve. Materials of construction comply with the requirements of the Water Research Centre (WRc) and M&E3 Reliable, leak free operation Compact body design AE30B and AE30C have a lockshield fitted as standard One valve covers all operating conditions making selection and replacement simple Simple lever and float operation Note A standard socket set will be required to operate the valve Standards 97/23/EC Approvals WRc; M&E3 Valve Data Approvals WRc M&E3 Body Design Conditions PN10 Body and Cap Material BS 2872 CZ 132 DZR Copper Alloy Cap O Ring Material WRc 9305512 Green Viton 75 Cold Hydraulic Test Pressure 15 bar g Connections (in. BSP M) Outlet 1//4 in. Connections (in. BSPP F) Inlet 1//2 in. Float Material Acetal Co Hostaform Stainless Steel Lockshield Valve Body, AE30B/AE30C BS 2872 CZ 132 DZR Copper Alloy Maximum Differential Pressure 8 bar Maximum Operating Pressure 10 bar g Maximum Operating Temperature 110°C Minimum Specific Gravity Of Water 0.926 Maximum Allowable Temperature 150 C Maximum Allowable Pressure 10 bar g Overall Body Diameter 56 mm Outlet Centre Offset 10 mm
New items
Valsteam ADCA Air Vent 345063 1/2 in, 1/8 in

Valsteam ADCA Air Vent 345063 1/2 in, 1/8 in

Vacuum Breaker The VB21 vacuum breakers are simple and reliable devices that automatically relieve or "break" an unwanted vacuum condition, restoring the atmospheric pressure. This device is particularly suitable for steam heated units of small and medium volume as heat exchangers, heating coils, calorifiers, jacketed kettles, steam boilers, etc. Connections are female screwed Note Vertical installation angled connection Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
New items
Reliance Automatic Air Vent AVEN100001 3/8 in BSP

Reliance Automatic Air Vent AVEN100001 3/8 in BSP

Automatic Air Vent High quality automatic air vents for use in heating systems to vent air when commissioning a system. The device consists of a polypropylene float connected to a simple valve. When the build-up of air within the float chamber exceeds a certain level the float drops, opening the valve and releasing the air trapped within the chamber. As the air is released, water replaces it, and moves the float back into the up position, which closes the valve Max. working pressure: 10 bar Max. working temperature: 110゚C Body: Standard brass Cap: Standard brass Float: Heat resistant polypropylene Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
New items
Spirax Sarco Air Vent, AE30A 1/2 in BSPP 1/4 in BSP

Spirax Sarco Air Vent, AE30A 1/2 in BSPP 1/4 in BSP

Automatic Air Vent AE30A Air eliminators AE30 and AE30A have been specifically designed for the removal of air and other non-condensible gases from industrial and commercial hot and chilled water systems. This then improves the circulation of the pressurized liquids. Typical areas where this can be applied are, suction lines to pumps, water storage tanks, mixing tanks and cold water lines. Materials of construction comply with the requirements of the Water Research Centre (WRc) and M&E3 Reliable, leak free operation AE30A has inbuilt check valve Compact body design One valve covers all operating conditions making selection and replacement simple Simple lever and float operation Valve Data Approvals WRc M&E3 Body Design Conditions PN10 Body and Cap Material BS 2872 CZ 132 DZR Copper Alloy Cap O Ring Material WRc 9305512 Green Viton 75 Cold Hydraulic Test Pressure 15 bar g Connections (in. BSP M) Outlet 1//4 in. Connections (in. BSPP F) Inlet 1//2 in. Float Material Acetal Co Hostaform Stainless Steel Lockshield Valve Body, AE30B/AE30C BS 2872 CZ 132 DZR Copper Alloy Maximum Differential Pressure 8 bar Maximum Operating Pressure 10 bar g Maximum Operating Temperature 110°C Minimum Specific Gravity Of Water 0.926 Maximum Allowable Temperature 150 C Maximum Allowable Pressure 10 bar g Overall Body Diameter 56 mm Outlet Centre Offset 10 mm
New items
Valsteam ADCA Air Vent AE16SS12 1/2 in

Valsteam ADCA Air Vent AE16SS12 1/2 in

Air Eliminator for Water Systems The AE16SS stainless steel air eliminator removes air from HVAC systems and is also suitable for non corrosive and/or dangerous liquids providing that their specific weight is not less than 0,75Kg/dm3. This ball float type automatic air eliminator can be used in combination with other air elimination and separation systems or directly applied at high points in the piping Connections are female screwed Vertical installation Corrosion-resistant Replaceable internal parts Cold and hot water systems Note It must be installed absolutely vertically at the points in the plant where the air tends to collect. The drain should be piped to a safe position Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
New items
Spirax Sarco Air Vent, AV13 1/2 in BSPP

Spirax Sarco Air Vent, AV13 1/2 in BSPP

Thermostatic Air Vent AV13 Body design conditions PN16 Valve body and cap in brass to BS2872 CZ122 Stainless steel capsule Strainer in stainless steel to ASTM A240 TP 304 Synthetic rubber high fluorine fluorocarbon O-rings Cold hydraulic test pressure 24 bar g Maximum operating pressure (saturated steam) 13 bar g Maximum operating temperature 260°C Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
New items
Reliance Automatic Air Vent AVEN100005 1/2 in BSP

Reliance Automatic Air Vent AVEN100005 1/2 in BSP

Automatic Air Vent High quality automatic air vents for use in heating systems to vent air when commissioning a system. The device consists of a polypropylene float connected to a simple valve. When the build-up of air within the float chamber exceeds a certain level the float drops, opening the valve and releasing the air trapped within the chamber. As the air is released, water replaces it, and moves the float back into the up position, which closes the valve Max. working pressure: 10 bar Max. working temperature: 110゚C Body: Standard brass Cap: Standard brass Float: Heat resistant polypropylene Air Vents Air vents automatically remove air and other incondensable gases from steam systems, reducing heat transfer and affecting steam temperature. They improve heat transfer, while saving energy, and maintain process performance where temperature is critical. Their use reduces corrosion and maintenance costs, promotes even heating and improves product quality.
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Air Eliminators and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Air Eliminators or any other product.
This depends on the Air Eliminators individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Air Eliminators and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Air Eliminators.
Yes. We keep updating our stock frequently and if a product like Air Eliminators is not in stock then we will let you know.