Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

Products Found: 21

Showing Results For: Loop & RCD Testers

Loop & RCD Testers


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Gossen Metrawatt
Rohs Verified
M507A, Gossen Metrawatt
99 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 519.92
Gossen Metrawatt
Rohs Verified
M507B, Gossen Metrawatt
100 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 519.92
Chauvin Arnoux
Rohs Verified
P06230304, Chauvin Arnoux
9 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 21.64
Chauvin Arnoux
Rohs Verified
P06230301, Chauvin Arnoux
34 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 23.25
Kewtech Corporation
Rohs Verified
FC2000, Kewtech Corporation
58 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 214.40
RCDT310-EN-BS, Megger
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 616.59
LRCD220-EN-BS, Megger
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 990.45
RCDT320-EN-BS, Megger
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 700.29
LTW315-EU-BS, Megger
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 611.01
LTW325-EU-BS, Megger
86 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 725.81
LT300-EN-BS, Megger
49 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 567.30
LTW425-EU-BS, Megger
4 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 739.35
LTW315-RS-BS, Megger
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 660.30
Megger
RCDT310, Megger
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 616.59
Megger
LTW325, Megger
7 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 715.17
Megger
RCDT320, Megger
6 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 700.29
RCDT320-FR, Megger
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 544.98
Megger
LT300, Megger
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 511.04
Megger
LRCD220, Megger
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 990.45
Megger
LTW425, Megger
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 829.75
LRCD220-FR, Megger
27 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 859.62
Showing
1 -

New Items
New items
RCDT310-EN-BS, Megger

RCDT310-EN-BS, Megger

RCDT310 & RCDT320 RCD Testers Two RCD testers that comply with EN61557 for testing, measuring or monitoring of protective measures. Tests 30mA, 100mA, 300mA and 500mA rated RCDs 1/2x I, I, 5x I tests standard, DC and selective RCDs 0° or 180° polarity tests on all RCDs Selective breakers have a time delay in tripping. When selected, trip test times are extended and a 30s delay is allowed between the measurement of the fault voltage and the application of the test current Selectable touch voltage inhibit and touch voltage display on the analogue bargraph 300Vac (25 to 45Hz) voltage measurement range Clear 20mm high digit LCD display with analogue arc bargraph Tough rubber armoured case with self-contained display cover that locks away underneath the instrument during use Safety input terminal interlock - prevents unsafe connection of test leads Safety lock-out prevents the test from operating when the circuit voltage is >300V RCDT320 model additional features 10mA/1A RCD extended test capability Backlit display and range selection ideal for low light environments Ramp Test measures & displays the actual trip current of an RCD. Ideal for diagnosing nuisance tripping of RCDs Auto testing allows remote testing from the RCD under test. The RCDT320 will automatically perform a 1//2 I, I and 5I test at both 0°and 180°. When the RCD trips the user resets it and the tester proceeds to the next test automatically. All results are displayed at the end of the test 25 to 450Hz Frequency measurement range Optional 2-wire test leads supplied 3-phase safe - Meets the requirements of BSEN 61010-1 for safe connection to a 440V Installation Category III supply (300V phase to Earth) Weatherproof to IP54 Dimensions (WxHxD): 190 x 75 x 140mm; Weight 980g Note RS is an authorised Megger distributor. Purchased though RS this product is eli...
New items
M507A, Gossen Metrawatt

M507A, Gossen Metrawatt

The Gossen Metrawat M50 loop resistance measuring instrument it is test instrument is used to measure earth-fault loop impedances and line impedances. Table of common protective devices can be displayed LED for measurement point illumination Patented test probe retainer Compact and rugged for service calls under harsh conditions and laboratory use
New items
FC2000, Kewtech Corporation

FC2000, Kewtech Corporation

Kewtech FC2000 Calibration Check Box The FC2000 Calibration Checkbox allows electricians to check their own 17th Edition test equipment and ensure that all meters are operating correctly and accurately. The Kewtech FC2000 Check Box doesn't replace the calibration requirements of testers but provides a quick and simple way to check instrument accuracy, reducing the risk of incorrect certification. Checks that 17th edition testers are maintaining their calibration Test lead nulling point Three continuity test points Three Insulation test points Two loop impedance test points plus the local loop 1/2, x 1, x 5 30mA current and time test settings Supplied with Mains lead, instruction manual.
New items
LRCD220-EN-BS, Megger

LRCD220-EN-BS, Megger

LRCD220 Loop & RCD Tester The LRCD200 series tester combines an Earth loop impedance tester with an RCD tester. The loop tester is a non-tripping test suitable for systems protected with 30mA or larger RCDs. The RCD testing supports 10mA to 1000mA RCDs with the full range of tests. Ramp testing provides a trip current test for the testing of nuisance tripping RCDs. Suitable for use on 110V or 3 phase supplies.,Designed to meet the tough environment of site work, the instruments are rubber armoured, have a built-in protective front cover, and meet the requirements of BS7671, IEC1010 and BSEN61557. All instruments are IP54 weatherproof. The combined instrument offers all the test functions necessary for live electrical testing requirements, in a simple and cost effective instrument. Built-in protective front cover Tough rubber armoured case Weatherproof to IP54 High current loop testing Phase to phase loop testing Auto RCD testing 1000mA RCD test Phase rotation 110V, 230V and 415V operation Backlit display Note RS is an authorised Megger distributor. Purchased though RS this product is eligible for the Megger extended 3 Year warranty Supplied with Durable hard carry case, instructions, 3 wire test lead with crocodile clips, BS1363 mains socket test lead, 8 off AA alkaline batteries.
New items
LTW325, Megger

LTW325, Megger

LTW 300 Series Earth loop impedance testers to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy 2 wire loop testing solution that does not trip 30mA RCDs and can be used on a wide range of voltages. Backlit display 0.01Ω resolution No-trip loop test on circuits with RCDs of ≥30 mA 3 phase circuits with RCD protection can be tested Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available. 10 second non trip loop test time with Auto test extension up to a further 10 seconds if noise is detected, to improve the accuracy of the test High current loop testing for supplies that do not have an RCD fitted AUTO START will start the loop test running as soon as the test leads are connected; no need to press the test button means much safer testing PFC Display up to 20kA Voltage and frequency measurement 110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the secondary winding. IP54 Weatherproof case Optional 10A fused 2 wired test leads and crocodile clip set Complies with IEC61010-1 300V CATIV safety standard and meets EN61557 Voltage measurement (ac only) 50V to 440V Accuracy ±2% ±1V Range 25Hz to 99.99Hz Accuracy ±0.1Hz A warning will be shown if applied voltage exceeds 440V Damage will occur if applied voltage exceeds 600Vrms Loop testing No-trip loop and high current loop test Source voltage LTW315: 100V to 280V (50Hz) LTW325: 50V to 440V (50Hz) Display range 0.01Ω to 2000Ω Accuracy ±5% ±0.03Ω Nominal test current No-Trip loop test 15 mA (at nominal 230Vac supply) High current loop test 4 A (at nominal 230 Vac supply) Operational range 0.30Ω to 1000Ω Prospective Fault Current (PFC) Prospective fault current Measured Source Voltage / Loop resistance ...
New items
M507B, Gossen Metrawatt

M507B, Gossen Metrawatt

The Gossen Metrawat M50 measuring instrument used for testing the characteristics of RCCBs. In particular, this involves the measurement of touch voltage, breaking time and breaking current for type A, AC, and S RCCBs, as well as type F mixed frequency RCDs as of recently. Table of common protective devices can be displayed Digital display, backlit color OLED display, switching between brief and detailed representation LED for measurement point illumination Patented test probe retainer Compact and rugged for service calls under harsh conditions and laboratory use
New items
LTW315-RS-BS, Megger

LTW315-RS-BS, Megger

LTW 300 Series Earth loop impedance testers to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy 2 wire loop testing solution that does not trip 30mA RCDs and can be used on a wide range of voltages. Backlit display 0.01Ω resolution No-trip loop test on circuits with RCDs of ≥30 mA 3 phase circuits with RCD protection can be tested Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available. 10 second non trip loop test time with Auto test extension up to a further 10 seconds if noise is detected, to improve the accuracy of the test High current loop testing for supplies that do not have an RCD fitted AUTO START will start the loop test running as soon as the test leads are connected; no need to press the test button means much safer testing PFC Display up to 20kA Voltage and frequency measurement 110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the secondary winding. IP54 Weatherproof case Optional 10A fused 2 wired test leads and crocodile clip set Complies with IEC61010-1 300V CATIV safety standard and meets EN61557 Voltage measurement (ac only) 50V to 440V Accuracy ±2% ±1V Range 25Hz to 99.99Hz Accuracy ±0.1Hz A warning will be shown if applied voltage exceeds 440V Damage will occur if applied voltage exceeds 600Vrms Loop testing No-trip loop and high current loop test Source voltage LTW315: 100V to 280V (50Hz) LTW325: 50V to 440V (50Hz) Display range 0.01Ω to 2000Ω Accuracy ±5% ±0.03Ω Nominal test current No-Trip loop test 15 mA (at nominal 230Vac supply) High current loop test 4 A (at nominal 230 Vac supply) Operational range 0.30Ω to 1000Ω Prospective Fault Current (PFC) Prospective fault current Measured Source Voltage / Loop resistance ...
New items
P06230304, Chauvin Arnoux

P06230304, Chauvin Arnoux

The Multimetrix VT11 is the wall plug tester and the rated voltage required for the device is the 230V. It have differential sensitivity up to 30 mA. Temperature range is 0 to 40 °C Relative humidity is < 80 % RH
New items
RCDT320-FR, Megger

RCDT320-FR, Megger

RCDT320 differential circuit breaker tester Differential circuit breaker tester that meets the requirements of NFC 15-100, EN6557-3 and IEC 61010 for testing low-voltage electrical wiring. 0 ° or 180 ° polarity selection. Selectable touch voltage and display on the analogue arc. 300 Vac voltage measurement range. 3-phase safe (the device will remain safe, even if it is connected across phases). Mains voltage measurement. Large digital display with a true analogue response. The rigid display cover folds out of the way during testing and locks down to protect the display when finished. Test locking - prevents testing when mains voltage exceeds 300 V. Supplied with a 3-wire test lead set fitted with crocodile clips, a mains plug test lead, 8 x AA rechargeable alkaline batteries and a hard carry case. Sealing: IP54. IEC 61010-1 compliant for safe use at 440 V on installations classified as Cat. III 600 V or Cat. IV 300 V. Single-phase test Single-phase test also on 110 V circuits Differential circuit breaker testing: 10, 30, 100, 300, 500 and 1000 mA (instantaneous and selective) 1/2I, I and 5I trip time test Selective breakers DC test Auto test sequence 0 ° / 180 ° polarity selection Touch voltage display Max. touch voltage (adjustable) (25 V / 50 V) Operating range 100 → 280 V Frequency measurement
New items
RCDT320, Megger

RCDT320, Megger

RCDT310 & RCDT320 RCD Testers Two RCD testers that comply with EN61557 for testing, measuring or monitoring of protective measures. Tests 30mA, 100mA, 300mA and 500mA rated RCDs 1/2x I, I, 5x I tests standard, DC and selective RCDs 0° or 180° polarity tests on all RCDs Selective breakers have a time delay in tripping. When selected, trip test times are extended and a 30s delay is allowed between the measurement of the fault voltage and the application of the test current Selectable touch voltage inhibit and touch voltage display on the analogue bargraph 300Vac (25 to 45Hz) voltage measurement range Clear 20mm high digit LCD display with analogue arc bargraph Tough rubber armoured case with self-contained display cover that locks away underneath the instrument during use Safety input terminal interlock - prevents unsafe connection of test leads Safety lock-out prevents the test from operating when the circuit voltage is >300V RCDT320 model additional features 10mA/1A RCD extended test capability Backlit display and range selection ideal for low light environments Ramp Test measures & displays the actual trip current of an RCD. Ideal for diagnosing nuisance tripping of RCDs Auto testing allows remote testing from the RCD under test. The RCDT320 will automatically perform a 1//2 I, I and 5I test at both 0°and 180°. When the RCD trips the user resets it and the tester proceeds to the next test automatically. All results are displayed at the end of the test 25 to 450Hz Frequency measurement range Optional 2-wire test leads supplied 3-phase safe - Meets the requirements of BSEN 61010-1 for safe connection to a 440V Installation Category III supply (300V phase to Earth) Weatherproof to IP54 Dimensions (WxHxD): 190 x 75 x 140mm; Weight 980g Note RS is an authorised Megger distributor....
New items
LTW425, Megger

LTW425, Megger

LTW425 The Megger LTW425 two wire earth loop tester verifies the loop impedance of a live electrical circuit, ie without the need to disconnect the electrical supply. Offers a high resolution 2-wire loop testing solution that does not trip 30 mA RCDs and can be used on a wide range of voltages. High resolution (0.001Ω) 2 wire testing + maxZ + (R1+R2) Backlit display 2 wire loop tests: Phase to Earth, Phase to Neutral or Phase to Phase 3 phase circuits with RCD protection can be tested Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available. 10 second non trip loop test time with Auto test extension up to a further 10 seconds if noise is detected, to improve the accuracy of the test High current loop testing for supplies that do not have an RCD fitted AUTO START will start the loop test running as soon as the test leads are connected; No need to press the test button means much safer testing PFC Display up to 40kA Voltage and frequency measurement 110 Vac systems including 110V centre tap to earth (55 V phase to earth) can be tested on the secondary winding. IP54 Weatherproof case Optional 10A fused 2 wired test leads and crocodile clip set Complies with IEC61010-1 300V CATIV safety standard and meets EN61557 Voltage measurement (ac only) 50V to 440V Accuracy ±2% ±1V Range 25Hz to 99.99Hz Accuracy ±0.1Hz A warning will be shown if applied voltage exceeds 440V Damage will occur if applied voltage exceeds 600Vrms Loop testing No-trip loop and high current loop test Source voltage 50V to 440V (50Hz) Display range 0.01Ω to 2000Ω Accuracy ±5% ±0.03Ω Nominal test current No-Trip loop test 15 mA (at nominal 230Vac supply) High current loop test 4 A (at nominal 230 Vac supply) Operational range 0.30Ω to 1000Ω High resolution loop test Source voltage 50 V to 440 V (50Hz) Display ...
New items
LTW315-EU-BS, Megger

LTW315-EU-BS, Megger

LTW 300 Series Earth loop impedance testers to verify the loop impedance of a live electrical circuit without the need to disconnect the electrical supply. The LTW300 series instruments offer a safe and easy 2 wire loop testing solution that does not trip 30mA RCDs and can be used on a wide range of voltages. Backlit display 0.01Ω resolution No-trip loop test on circuits with RCDs of ≥30 mA 3 phase circuits with RCD protection can be tested Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available. 10 second non trip loop test time with Auto test extension up to a further 10 seconds if noise is detected, to improve the accuracy of the test High current loop testing for supplies that do not have an RCD fitted AUTO START will start the loop test running as soon as the test leads are connected; no need to press the test button means much safer testing PFC Display up to 20kA Voltage and frequency measurement 110Vac systems including 110V centre tap to earth (55V phase to earth) can be tested on the secondary winding. IP54 Weatherproof case Optional 10A fused 2 wired test leads and crocodile clip set Complies with IEC61010-1 300V CATIV safety standard and meets EN61557 Voltage measurement (ac only) 50V to 440V Accuracy ±2% ±1V Range 25Hz to 99.99Hz Accuracy ±0.1Hz A warning will be shown if applied voltage exceeds 440V Damage will occur if applied voltage exceeds 600Vrms Loop testing No-trip loop and high current loop test Source voltage LTW315: 100V to 280V (50Hz) LTW325: 50V to 440V (50Hz) Display range 0.01Ω to 2000Ω Accuracy ±5% ±0.03Ω Nominal test current No-Trip loop test 15 mA (at nominal 230Vac supply) High current loop test 4 A (at nominal 230 Vac supply) Operational range 0.30Ω to 1000Ω Prospective Fault Current (PFC) Prospective fault current Measured Source Voltage / Loop resistance ...
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Loop & RCD Testers and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Loop & RCD Testers or any other product.
This depends on the Loop & RCD Testers individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Loop & RCD Testers and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Loop & RCD Testers.
Yes. We keep updating our stock frequently and if a product like Loop & RCD Testers is not in stock then we will let you know.