Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Pilz Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Pilz




New Items
New items
PNOZ X2 24VAC/DC 2n/o, Pilz

PNOZ X2 24VAC/DC 2n/o, Pilz

PNOZ X2 and X2.1, Dual Channel Supply: 24Vdc at E-Stop pushbuttons 1 or 2 channel input Feedback control loop for monitoring external relays/contactors LED indication: power, Channel 1 and 2 Relay output: 2 N/O Monitored manual reset DIN rail mounting Standards BS EN 60204-1
New items
PNOZ s10 24VDC 4 n/o 1 n/c, Pilz

PNOZ s10 24VDC 4 n/o 1 n/c, Pilz

PNOZsigma series contact extension blocks Extension modules for PNOZ sigma series safety blocks. The extension blocks provide reinforcement and increase the number of safety contacts on a base device. The contact extension block expands an existing electrical circuit. Safety is still guaranteed, even if a component fails. Removable terminals with connection via spring terminals. DIN rail mounting. Standards EN 60947-5-1, EN 60204-1 VDE 0113-1
New items
PNOZ s5 24VDC 2 n/o 2 n/o t, Pilz

PNOZ s5 24VDC 2 n/o 2 n/o t, Pilz

PNOZsigma s5 Safety relay adapted for emergency stop pushbuttons, safety gates and light curtains Redundant internal design with self-monitoring Safety device remains active even if the component fails Removable terminals with connection via spring terminals Display LEDs for relay status DIN rail mounting 1 solid state output Standards EN 60947-5-1, EN 60204-1 VDE 0113-1
New items
PNOZ s8 24VDC 2 n/o, Pilz

PNOZ s8 24VDC 2 n/o, Pilz

PNOZsigma series contact extension blocks Extension modules for PNOZ sigma series safety blocks. The extension blocks provide reinforcement and increase the number of safety contacts on a base device. The contact extension block expands an existing electrical circuit. Safety is still guaranteed, even if a component fails. Removable terminals with connection via spring terminals. DIN rail mounting. Standards EN 60947-5-1, EN 60204-1 VDE 0113-1
New items
772171, Pilz

772171, Pilz

PNOZmulti 2 Motion Monitoring Modules The PNOZ m EF *MM expansion module connects to a base unit from the PNOZmulti 2 configurable control system. Two models are available: PNOZ m EF 1MM provides safe monitoring of one axis and PNOZ m EF 2MM provides safe monitoring of two independent axes. Features and Benefits Can be configured in the PNOZmulti Configurator Monitoring of 1 axis, stock no. 918-6617 Monitoring of two independent axes, stock no. 918-6611 Measured value recorded by proximity switch and encoder LED display for supply voltage, diagnostics, axis status and errors Support the safe drive function in accordance with EN 61800-5-2 Applications Safe speed monitoring (SSM) Safe speed range monitoring (SSRM) Safe direction of movement monitoring (SDIM) Safe operating stop monitoring (SOSM) Analogue voltage (track S) Standards EN ISO 13849-1 PLe; EN ISO 13849-1 Cat. 4; EN IEC 62061 SIL CL 3; IEC 61511 SIL 3. Approvals CE, cULus Listed, TÜV, BG, CCC. Supplied with Screw terminals. Safety Controller
New items
540080, Pilz

540080, Pilz

PSENcode Large Actuator The PSEN cs1.1 1 actuator is designed for use with the PSENcode large design non-contact safety switches. Features and Benefits Transponder technology Large design IP6K9K protection Approvals CE, cULus Listed, TÜV.
New items
542000, Pilz

542000, Pilz

PSENcode Slim Non-Contact Safety Switch, Coded The PSEN cs5.11 and PSEN cs5.1p safety switches are coded and only switch when used with an actuator from the PSEN cs1.1 series. There is no restriction on the number of times the actuator can be used and reset. Features and Benefits Transponder technology for presence detection Coded switch Dual-channel operation 2 safety inputs for series connection of multiple safety switches 2 safety outputs Safety Device Diagnostics (SDD) Safety Device Diagnostics can be used to poll sensor information, to perform actions and to read configuration parameters Diagnostic input for Y1 for Safety Device Diagnostics (SDD) Signal output/diagnostic output Y32 for Safety Device Diagnostics LED display for state of actuator detection, state of the inputs and supply voltage/fault IP66 / IP67 protection PSEN cs5.11 (stock no. 918-6667 ) 1 actuation direction with 3 approach directions: square marking for normal operating distance M12 8 pole male connector 30 N holding force PSEN cs5.1p (stock no. 918-6661 ) 4 actuation directions, each with 3 approach directions: square marking for normal operating distance and triangle marking for short operating distance M8 8 pole male connector Caution The safety level PLe (Cat. 4)/SIL CL 3 is only achieved if the safety outputs use 2-channel processing. Standards EN 60947-5-3; EN 62061 SIL CL 3; EN ISO 13849-1 PLe Cat. 4; EN ISO 14119 Coding level Low, Type4. Approvals CE, TÜV, UL/cUL, FCC, IC, ECOLAB. Supplied with Actuator.
New items
570230, Pilz

570230, Pilz

PSENmech Safety Switch The PSENmech from Pilz is a mechanical safety switch with separate actuator, suitable for mounting on safety guards. The interlock switch is triggered if the guards are opened, stopping any hazardous machine movement via a Pilz evaluation device. Flexibility and speed during installation plus high plant availability Compact design Can be connected to all Pilz evaluation devices Up to four horizontal and four vertical approach directions Operating temperature -30 to +80°C Screw terminals M20 Plastic bodied design IP65 protection Standards VDE 0660 T100, EN 60947-1, VDE 0660 T200, EN 60947-5-1, IEC 60947-5-1 GS-ET-19 Approvals EC, BG, CCC, cCSAus Interlock Switch
New items
774709, Pilz

774709, Pilz

PNOZ X10, Dual Channel Introducing the PNOZ X10 range of safety relay from the well-known brand PILZ, manufacturer of many safety related monitoring products. The PNOZ X10 range is the top of its class offering you different modes of operation including, single, automatic and dual channel functions. You will find that the PNOZ X10 has many different applications that you can use that offer you versatility in the face of machine safety. Features and benefits • LED indicator statuses to support switching channel status between 1 or 2 signals & also for monitoring the supply voltage currently in the relay • Featuring 6 safety contacts (instantaneous) and 4 auxiliary contacts furthering the reliability of the machines safety output. • DIN rail mounting as standard • Single/Dual channel operation • Detection of short circuits across the contacts which can specifically detect earth faults and short circuiting. Safety features • The circuit is redundant with built in self-monitoring • Safety functions remain effective in the case of a component failure • Correct opening and closing of the safety functions is tested automatically at the end of each of the relays on/off safety cycles. • Your X10 is short circuit proof, using an electronic fuse on a DC supply provides this reliability. Applications • Emergency stop buttons • Safety gate limit switches • Reset buttons • Light barriers Technical safety parameters • EN 60947-5-1 • EN 60204-1 • VDE 0113-1
New items
774500, Pilz

774500, Pilz

PNOZ XV2 Safety Relay, Adjustable Time Delayed The PNOZ XV2 range of safety relays from PILZ offers you safety and performance of a top branded safety relay all in one. The PNOZ XV2 offers you different modes of operation such as single or dual channel switches. Suitable for several different applications which are listed below. Features and benefits: • DIN rail mounted with screw terminals • 2 instantaneous delay-on re-energised safety contacts • LED operating voltage displayed alongside switching psitions and also the reset circuit • Connections built in for safety limit switches, e-stops and more • Single or dual channel operation • Simple and fast wiring saving you time, effort and money long term • Save costs when exchanging units (there’s no need to rewire therefore you should eliminate potential wiring errors). • Electromechanical, potential-free Safety features • The circuit is redundant with built-in self-monitoring. • The safety function remains effective in the case of a component failure. • The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. • International certification • Faster commissioning and simple wiring through units with plug-in terminals • High plant availability and short downtimes thanks to a convenient diagnostic options on the device Applications • E-STOP pushbuttons • Safety gate limit switches • Reset buttons Technical safety parameters • EN 60947-5-1 • EN 60204-1 • VDE 0113-1 Standards EN 60204-1, EN 62061, EN ISO 13849-1, VDE 0113-1, EN 60947-5-1. Approvals CE, cULus Listed, TÜV, KOSHA, CCC.