Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Red Lion Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Red Lion




New Items
New items
P1611100, Red Lion

P1611100, Red Lion

T16 / P16 — Temperature and Process Controller, 48 x 48 mm 48 x 48 mm basic PID controller 2 types available: - Temperature controller (T16) - Process controller (P16) Simple operation using 4 buttons 2-row, 4-digit LCD display Self-optimisation of process parameters Relay or analogue output With or without alarm output Signal input - Type T16: Thermocouple type J, K, N, S, T, E, R, B PT100, -5 → 56 mV or 0 → 320 Ω - Type P16: 0 / 4 → 20 mA and 0 → 10 V Sampling time: Resolution: 1 or 0.1 °C Accuracy: 0.3% of range ±1 °C Control output - Relay output: N/O, 250 VAC / 3 A - Analogue output: 0 → 20 mA or 0 → 10 V, freely scalable Alarm output: 2 N/O (common earth) 250 VAC / 3 A Can also be programmed as 2nd control output (cooling) Data security: EEPROM, min. 10 years Power supply - DC version: 18 → 36 VDC (4 W) / 24 VAC (7 VA) - AC version: 85 → 250 VAC (8 VA) Electrical connection: Screw terminals Mounting: Panel mounting Housing material: Plastic case Protection class: IP65 (front) Dimensions (H x W x D): 50 x 50 x 115 mm Panel cut-out: 45 x 45 mm Weight: approx. 179 g Ambient temperature: 0 °C → +50 °C Stock no.: Controller type: Voltage power supply: Control out put: Alarm out- put: 614-3917 Temperature 18 → 36 VDC / 24 VAC Relay - 614-4033 Temperature 85 → 250 VAC Relay - 614-3939 Temperature 18 → 36 VDC / 24 VAC Relay Yes 614-3923 Temperature 85 → 250 VAC Relay Yes 614-3951 Temperature 18 → 36 VDC / 24 VAC Analogue Yes 614-3945 Temperature 85 → 250 VAC Analogue Yes 614-3989 Process controller 18 → 36 VDC / 24 VAC Relay - 614-3973 Process controller 85 → 250 VAC Relay - 614-4005 Process controller 18 → 36 VDC / 24 VAC Relay Yes 614-3995 Process controller 85 → 250 VAC Relay Yes 614-4027 Process controller 18 → 36 VDC / 24 VAC Analogue Yes 614-4011 Process controller 85 → 250 VAC Analogue Yes Approvals  ...
New items
PAXDP010, Red Lion

PAXDP010, Red Lion

PAX Industrial Indicator, Current, Voltage, Temperature, Resistance Can be used as a highly flexible and precise laboratory instrument The sturdy plastic housing is also designed for tough industrial use Can be quickly and securely projected via PC or directly using 5 buttons Can be retrofitted with plug-in options PAX D for standard / analogue signals PAX T for thermocouples and PT100 Inputs: PAX D: Standard / analogue signals: ±200 mV, ±2 V, ±20 V, ±300 V, ±200 μA, ±2 mA, ±20 mA, ±200 mA, ±2 A and 100 Ω, 1000 Ω, 10 kΩ PAX T: Thermocouples: types T, E, J, K, R, S, B, N, C. Resistance thermometer: PT100 Display capacity: 5-digit, 14 mm high red LED. Device freely definable. Digital display freely scalable. Linearisation with 16 dots for PAX D. Indicators: MAX, MIN, TOT (total) SP1 → SP4 (output status) Backlit device: Physical device very easily attached behind the display. Procedure: Programmed using front buttons, or using Windows software on the PC. During programming, it is decided which displays and inputs are possible after activation of the programming lockout and which remain locked. User inputs: 3 programmable inputs available. Functions: reset total / display / min. value / max. value, Tara, pressure build-up, programming lockout etc. Adjustable by switching using jumper PNP or NPN. Total counter: 10-digit total counter can create a product from the signal and the time. Either totalled automatically or with user input. Time base and factor make the device flexible. Voltage supply: 230 VAC: 85 → 250 VAC 50 / 60 Hz or 24 VDC: 11 → 36 VDC / 24 VAC Sensor power supply: PAX D: 24 VDC ±5%, regulated, max. 50 mA, reference voltage and current. Measuring rate: 20 measurements/s, A/D transducer 16-bit resolution Output option cards: User can easily retrofit various output cards. At the most, every device can hold an interface card, a relay output card and an analogue output card. Plug-in Interface card: 1. RS 232, Half-duplex ...
New items
DP5P0000, Red Lion

DP5P0000, Red Lion

DP5 Analogue Input Multifunction Meter The DP5 panel meter offers many features and performance capabilites to suit a wide range of industrial applications. These meters are available in three different models to handle various analogue inputs, including DC Voltage/Current, Process and Temperature inputs. DC Voltage/current input ( 905-5526 & 905-5529 ) Process input ( 905-5523 ) 5-digit (14.2 mm) LED display Programmable function keys/user input 9-digit (integrator) with batching Optional custom units overlay with backlight NEMA 4X/IP65 sealed front bezel Red Lion
New items
IFMA0065, Red Lion

IFMA0065, Red Lion

IFMA - frequency to analogue converter Converts a frequency into a standard signal Galvanic 3-way isolation All sensors are adjustable via DIP switch Easy to mount onto DIN rail Inputs: PNP, NPN, permanent magnet, relay, CMOS or TTL Frequency range: Continuous period measurement: adjustable from 0 → 1 Hz to 0 → 25 kHz Response time: 5 ms + 1 period → 10 s + 1 period Output: Voltage: 0 → 10 VDC or 0 → 5 VDC / 10 mA Current: 0 → 20 mA or 4 → 20 mA INFO LEDs Red LED lights up when output is active Green LED lights up when signals are being received Power supply: 9 → 32 VDC or 85 → 250 VAC Sensor power supply: AC version only: + 12 VDC ±25% max. Accuracy: 0.1% from working area Operating temperature: 0 °C → +50 °C Storage temperature: -40 °C → +80 °C Housing: stable plastic housing Insulation: 2.2 kV between power supply, input and output Dimensions (WxHxD): 28 x 107 x 79 mm
New items
T1610010, Red Lion

T1610010, Red Lion

T16/P16 PID Temperature Controller The T16 model Temperature Controller accepts signals from various temperature sensors while the P16 model accepts either a 0-10VDC or 0/4-20 mA DC input signal. Both controllers provide an accurate output control signal to maintain a process at a set point value. The comprehensive programming allows these controllers to meet a wide variety of application requirements. • 2 line by 4-digit (7.6 mm, top line & 5.1 mm, bottom line) LCD display • PID control for both heating & cooling, with reduced overshoot • T16 model accepts TC & RTD • P16 accepts 0-10VDC & 0/4-20 mA signals • On-demand auto-tuning of PID settings • DC analogue output (optional) • User-programmable function button • PC or front panel programming Red Lion Temperature Controllers
New items
MPAXT000, Red Lion

MPAXT000, Red Lion

Designed for use with LPAX5 or EPAX5 (LPAX0500 or EPAX0500)Temperature Inputs ModuleSupports Thermocouples -T, E, J, K, R, S, B, N, C or Custom Scaling OperationEasy module installationRequires 85 to 250 VAC Input PowerProgrammed using Crimson® 2.0 software
New items
MPAXI030, Red Lion

MPAXI030, Red Lion

Designed for use with LPAX6 (LPAX0600)Count/ Rate/ Serial Slave ModuleSupports Setpoint, Comms, and AnalogEasy module installationRequires 11 to 36 VDC (24 VDC nominal) Input PowerProgrammed using Crimson® 2.0 software
New items
PAXLSG00, Red Lion

PAXLSG00, Red Lion

Strain Gage Meter / Millivolt Meter 1/8 DIN (50 mm x 97 mm) 3.5 Digit, 0.56" (14.2 mm) LED High Sensitivity, 10mV full scale Built-in Excitation 5 or 10 VDC Selectable Decimal Points Over-Range Indication
New items
LD4T06P0, Red Lion

LD4T06P0, Red Lion

4" High Red LED Digits (adjustable intensity)6 Digit Display for Bi-directional Timing5 Digit Display for Cycle CountingProgrammable Scaling and Decimal PointsCount Speeds up to 500HzUser Defined Setpoint OutputSingle 5 Amp Form C RelayAluminium Case ConstructionCommunications (RS-232/485)50 to 250VAC / 21.6 to 250VDC Universal Input Power660 x 200 x 58mm Dimensions
New items
MP62TA00, Red Lion

MP62TA00, Red Lion

Magnetic Pickups A Magnetic Pickup consists of a permanent magnet, a pole-piece, and a sensing coil all encapsulated in a cylindrical case. An object of iron, steel, or other magnetic material, passing closely by its pole-piece causes distortion of the magnetic flux field passing through the sensing coil and pole-piece, which in turn generates a signal voltage. The magnitude of the signal voltage depends on the relative size of the magnetic target, its speed of approach, and how close it approaches. The polarity of the signal depends on whether the target is moving toward or away from the pole-piece. Magnetic Pickups are most frequently used to sense passing teeth on a gear, sprocket, or timing belt wheel, to bolt-heads, key-ways, or other moving machine mounted targets. Typical targets and resulting signal wave forms are shown within the datasheet. Selecting a magnetic pickup is a matter of matching a pickup to a gear (or other target), to provide enough input signal to a tachometer, speed-switch, or other device for operation at the required minimum speed. The open-circuit output from a magnetic pickup is directly proportional to speed, and once the minimum operating speed conditions have been met, excess signal will always be available at higher speeds. Self generating No external power needed Wide operating temperature range Epoxy encapsulated Mechanically rugged Impervious to dirt, oil and water No maintenance required M12 connector (Model specific) For use with speed switches, digital tachometers, frequency to D.C. converters Magnetic Pickups Simple & Reliable Pulse Generators Note Magnetic Pickups are used primarily for tachometer and other speed related functions. They are not normally used for counting since loss of counts will occur at low speeds. Therefore, counters are not designed to accept outputs directly from conventional magnetic pick...
New items
PAXLBK30, Red Lion

PAXLBK30, Red Lion

Accessories for PAX Series Meters Accessories for use with PAX Series Meters. Label kits Provides a unique way to identify the display with one of 189 different engineering units. The label lights up from the inside the meter where it is protected from washdown and dirty environments. Simply select the appropriate label from the kit and apply to the plastic frame. - RS stock no: 905-5664 , For use with PAX meters - RS stock no: 905-5327 , For use with PAX Lite meters 1/8 DIN Enclosure Enclosure designed for applications requiring a water resistant instrument enclosure. The ENC5B ( 905-5539 ) can be used for free-standing or securely fastened to a mounting surface. - Rugged polycarbonate construction - Completely sealed for NEMA 4X/IP65 wash-down - Easy mounting options USB Programming Option Card The plug-in card ( 905-5703 ) plugs into the main circuit board of any PAX unit and works in conjunction with the Crimson® programming software that enables the user to configure a PAX meter from a PC. - USB virtual comms port - 300-19.2K baud rate Red Lion