Enrgtech

Deliver to

United Kingdom

Categories

Brands

Part Numbers

Top Products

0

0.0 / 5

Reviews 0 Not Rated Yet
Allen Bradley Guardmaster Profile

Website
Manufacturer Type
Company Size
Location
Founded
Specialties
Reviews
5 star
(0%)
4 star
(0%)
3 star
(0%)
2 star
(0%)
1 star
(0%)

Be the first to review this manufacturer.
Don’t hesitate to ask questions for better clarification.

Featured Products


Popular Categories For Allen Bradley Guardmaster




New Items
New items
450L-B4FN1050YD, Allen Bradley Guardmaster

450L-B4FN1050YD, Allen Bradley Guardmaster

Bulletin 450L GuardShield POC safety light curtains are unlike traditional safety light curtains, which are based on separate transmitter and receiver units. This next generation light curtain system features patented technology, which allows each transceiver to be used as a transmitter or receiver via an innovative plug-in module. Each transceiver can be used either as a transmitter or receiver via an innovative plug-in module Features an active protective field that senses over the entire length of a transceiver Offers a wide range of protection heights 150…1950 mm in increments of 150 mm Features a compact housing design 30 x 30 mm 450L-B Guard Shield 14mm (0.55 in.), 1050 mm (41.37 in.)
New items
440N-A02025, Allen Bradley Guardmaster

440N-A02025, Allen Bradley Guardmaster

Ferrogard 6, 9 & 10 Slim Non Contact Safety Switch The Ferrogard FRS 6, 9 and 10 are magnetically actuated non-contact safety switches which offer reliability and a high tolerance to misalignment. Designed to be installed on a guard door, the action of the magnetic actuator being removed from the switch opens the N.C. safety contacts therefore isolating the control power to the machines primary control element. Moulded in ABS plastic with a slim rectangular housing to accommodate narrow mounting areas and sealed to IP67 (NEMA 6P), these non-contact switches are ideal for wet environments. They have two active sensing faces allowing more flexible mounting options. Slim housings to accomodate narrow mounting areas Two active sensing faces allowing more flexible mounting options Operating distance for safety contacts: make 12mm; break 23mm Operating temperature range: -10°C to +65°C M4 mounting IP67 rating (NEMA 6P) Cat. 1 Device per EN954-1 Dual channel interlocks suitable for Cat. 3 or 4 systems Approvals CE Marked for all applicable directives and cULus. Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, ANSI B11.19, AS4024.1.
New items
440E-LL5SN8, Allen Bradley Guardmaster

440E-LL5SN8, Allen Bradley Guardmaster

Our Lifeline™ 4 Cable Pull Switches can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The system includes a rope status indicator and emergency stop button mounted on the switch lid. This switch is also available in stainless steel 316 and is suitable for external use, applications where there are hygiene requirements, and other situations where a level of corrosion resistance is required Provide switch span of 75...125 m Includes universal mounting and operation Includes lid mounted emergency stop button, designed to conform to ISO 850 Provides switch lockout on cable pulled and cable slack Includes cable status indicator on switch lid Offers stainless steel 316 version 440E Lifeline Emergency Cable Pull Switches - Lifeline 5 standard housing without E-stop, 2 OSSD Inputs, 2 OSSD Outputs, 1 Aux Output, 1 Tension Output, 8-Pin Micro (M12)
New items
2080-OW4I, Allen Bradley Guardmaster

2080-OW4I, Allen Bradley Guardmaster

Micro800 Plug-in Modules 12/24V Digital Plug-ins These digital plug-in modules provide transistor outputs for switching a variety of 12/24V DC voltages to field loads and for detecting 12/24V signals from field devices. AC/DC Relay Output Module The 2080-OW4I is a 4-channel relay output and provides dry contact relay closure outputs for switching a variety of AC and DC voltages to field loads. Approvals cULus, CE, C-Tick, KC.
New items
440G-T27241, Allen Bradley Guardmaster

440G-T27241, Allen Bradley Guardmaster

TLS-GD2 Solenoid Interlock Switch, for Demanding Applications Features & Benefits Note The TLS-GD2 is a positive mode, tongue operated guard locking interlock switch that locks a machine guard closed until power is isolated and ensures that it remains isolated while the guard is open. The switch has three safety (N.C.) contacts and two auxiliary (N.O.) contacts. The head of this interlock switch has two entry slots and it can be rotated to provide four actuator entry points. A blanking plug is provided to seat the unused slot. The guard may only be opened when a signal is applied to the TLS-GD2 internal solenoid which releases the lock mechanism. Therefore this solenoid interlock switch is ideal for machines which do not stop immediately or where premature interruption of the machine could cause damage to tooling and components or cause an additional hazard. The safety switch is available in three types. The TLS-1 GD2 and TLS-3 GD2 incorporate a power-to-release function. Two manual release points with security screws allow the locked TLS-GD2 to be released in emergencies. An optional lid-mounted key-release style can also be supplied. The TLS-2 GD2 has a power-to-lock function. Each type of switch has five sets of contacts of various forms and are suitable for use with PLCs. The TLS-1 GD2 and TLS-3 GD2 are both available with escape release options. They are intended for machine guarding with full body access. The switch is installed so that the escape release push button on the rear side is accessible from inside the hazardous area. This allows the intentional unlocking of the TLS-GD2 from inside a hazardous area, providing a means of escape for a person who may become trapped. A stainless-steel actuator guide is fitted to protect the switch from actuator damage due to poor guard alignment or guard wear. TLS-GD2 has an ingress protection rating ...
New items
440P-MRPB22B, Allen Bradley Guardmaster

440P-MRPB22B, Allen Bradley Guardmaster

Allen-Bradley Senator Limit Switches The Senator is a large metal safety limit switch with the option of rotating the head in 90 increments before installation to allow ease of mounting. They can be used in applications other than guard doors, for example on moving machine beds, crane arms, lifts, elevators, etc.Operation of the safety limit switch is achieved by the sliding action of the guard or other moving object deflecting the plunger or lever. For safety applications it is important that upon actuation, the guard or other moving objects should not pass completely over the switch and allow the plunger or lever to return to its original position. Positive operation, forced disconnection of contactsSnap-acting, slow make before break or slow break before make contact blocksThree actuator heads available: Roller Plunger, Short Lever or Spring RodThree contacts configurations available: 1NC/1NO, 2NC/2NO or 3NC/1NOApprovals cULus, TUV and CE marked for all applicable directives.Standards Conforms to EN 50041, EN 1088, EN 60947-5-1, EN 292 and EN 60204-1.Safety Limit Switch
New items
440N-Z21W1PA, Allen Bradley Guardmaster

440N-Z21W1PA, Allen Bradley Guardmaster

MC2, Coded, IP69K Non-contact actuationMagnetic coded sensingHigh tolerance to misalignmentLED indication2 N/C solid state relay outputs and 1 PNP auxiliary outputSwitching current: 200 mA @ 24VdcSupply Voltage: 24VdcIP 69K protection ratingCategory 1 device per EN 954-1, dual channel contacts suitable for Cat 3 or 4 systems
New items
440F-A1308, Allen Bradley Guardmaster

440F-A1308, Allen Bradley Guardmaster

Closing Caps, Connector & Cable and Terminators The Safedge can be cut into a number of lengths to guard different points. Closing Caps, Cable Connectors and Terminators (resistors) can be used to seal the Safedge system. Closing Caps stock no. 249-6172 is used to close 0110N profiles stock no. 249-6239 is used to close 1610N profiles Connector & Cable stock no. 249-7210 is 1m long Terminators stock no. 873-2174 is a 6k resistor (yellow) for series termination stock no. 873-2178 is a 15k resistor (blue) for parallel termination Safety Edge
New items
450L-B4HN1650YD, Allen Bradley Guardmaster

450L-B4HN1650YD, Allen Bradley Guardmaster

Bulletin 450L GuardShield POC safety light curtains are unlike traditional safety light curtains, which are based on separate transmitter and receiver units. This next generation light curtain system features patented technology, which allows each transceiver to be used as a transmitter or receiver via an innovative plug-in module. Each transceiver can be used either as a transmitter or receiver via an innovative plug-in module Features an active protective field that senses over the entire length of a transceiver Offers a wide range of protection heights 150…1950 mm in increments of 150 mm Features a compact housing design 30 x 30 mm 450L-B Guard Shield 30mm (1.18 in.), 1650 mm (65.01 in.)
New items
450L-B4FN0600YD, Allen Bradley Guardmaster

450L-B4FN0600YD, Allen Bradley Guardmaster

Bulletin 450L GuardShield POC safety light curtains are unlike traditional safety light curtains, which are based on separate transmitter and receiver units. This next generation light curtain system features patented technology, which allows each transceiver to be used as a transmitter or receiver via an innovative plug-in module. Each transceiver can be used either as a transmitter or receiver via an innovative plug-in module Features an active protective field that senses over the entire length of a transceiver Offers a wide range of protection heights 150…1950 mm in increments of 150 mm Features a compact housing design 30 x 30 mm 450L-B Guard Shield 14mm (0.55 in.), 600 mm (23.64 in.)
New items
440J-A04N, Allen Bradley Guardmaster

440J-A04N, Allen Bradley Guardmaster

Enabling Switch, 440J Series Hand-operated grip style enabling device. Underneath the rubber boot, called the trigger switch, the 440J enabling device has two three-position switches. The contacts are closed when the actuator is in the mid-position (partly depressed). The contacts are open when the actuator is in the rest (released) position and in the fully pressed position. When transitioning from fully pressed to released, the contacts remain open. The 440J meets the requirements of IEC 60947-5-8:2006, which was written to describe the performance and design requirements of three-position enabling devices. The model with the normally open contact is typically used as a jog or reset function. The safety system design must only allow the use of the jog or reset function when the trigger switch is in the mid-position. 2 N/C direct-opening action Operating force; Position 2: 15 N approx., Position 3: 50 N max. Direct opening force; 90 N Maximum actuation frequency; 1200 operations per hour Note Base plate included. If operation of the switch contacts is all that is needed use the holding bracket 440J-A00N. Additional accessory brackets can be added to achieve various arrangements. The 440J-A01N right angle bracket accommodates the 440K-A11238 (standard actuator) which is used with the standard Trojan 6 or Trojan T15 and the 440G-A27011 (GD2 actuator) which is used with the GD2 interlocks. With two additional screws, the right angle bracket can be mounted to the 440J enabling switch for horizontal mounting. An actuator can also be mounted for vertical use without the 440J-A01N bracket. Mounting plate 440J-A02N has multiple pre-drilled and tapped holes to facilitate mounting of a single 440K-MT (MT-GD2) or 440K-T (Trojan) interlock. Four additional through-holes at the corners allow mounting of the plate to a flat surface. The 440J-A03N accessory mounts to...
New items
450L-APR-ED-8, Allen Bradley Guardmaster

450L-APR-ED-8, Allen Bradley Guardmaster

Muting Light Curtain Monitoring Relays allow the automatic temporary suspension of the safety function if certain conditions are met. In material handling applications, material is allowed to pass through the protective field without shutting down the machine. In addition to muting, these modules monitor up to three light curtains with presence sensing device initiation (PSDI) Allows the automatic temporary suspension of the safety function if certain conditions are met Monitors up to three light curtains with presence sensing device initiation (PSDI) 450L Plug-in, Bottom(connection), Receiver, EDM, M12, 8 pin, male